Heath Zenith SL-9526 - Manual
Heath Zenith SL-9526 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; Wall Mount; Turn power off at the fuse or circuit breaker.
- Page 3 – Bottom of Sensor
- Page 4 – TROUBLESHOOTING GUIDE; No Service Parts Available for this Product.
- Page 6 – FUNCIONAMIENTO; Resumen de las modalidades del; PRUEBA; Requisitos
- Page 7 – INSTALACION; Blanco a blanco
- Page 9 – GUIA DE INVESTIGACION DE AVERIAS; SERVICIO TÉCNICO; No hay piezas de servicio disponibles para este producto.
- Page 11 – FONCTIONNEMENT; Résumé du mode de commutation; PRIORITÉ MANUELLE; Exigences
- Page 12 – D’É; Montage mural
- Page 13 – Bas du détecteur
- Page 14 – GUIDE DE DÉPANNAGE; SERVICE TECHNIQUE; Aucune pièce de rechange n’est disponible pour ce produit.
© 2003 DESA Specialty Products™
598-1147-00
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Auto
1, 5, 10 min.
x
Manual
Until Dawn*
x
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• S o m e c o d e s r e q u i r e i n s t a l l a t i o n b y a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Model SL-9526
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Motion Sensor Light
Control
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Gasket
4 Screws
(2 sizes included)
2 Flood Lamps
2 Wire
Connectors
This package includes:
Light Control
Sensor
Cover
Plate
Lamp Holders
2 Shells
Light Shield
As an ENERGY STAR
®
Partner, Heath
®
/Ze-
nith has determined that this product meets
the ENERGY STAR
®
guidelines for energy
efficiency. This product is ENERGY STAR
®
compliant when used with 120 Watt bulbs.
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 598-1147-00 INSTALLATION For easy installation, select an existing light with a wallswitch for replacement. W IRE THE L IGHT C ONTROL . ❒ Twist the junction box wires and fixture wires togetheras shown. Secure with wire connectors. M OUNT THE L IGHT C ONTROL . ❒ Align the Light Control cover plate...
3 598-1147-00 Motion Motion TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. Sensor The detector is most sensitive to motion across its fieldof view. ❒ Loosen the clamp screw in thesensor ball joint and gently ro-tate the sensor. ❒ Walk through the coverage areanoting where you ar...
4 598-1147-00 SYMPTOM Lights will not comeon. L i g h t s c o m e o nin daylight. Lights come on forno apparent rea-son. POSSIBLE CAUSE 1. Light switch is turned off.2. F l o o d l i g h t i s l o o s e o r burned out. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turn-off is in eff...