Heath Zenith SH-5597 - Manual

Heath Zenith SH-5597

Heath Zenith SH-5597 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – Bulb Installation and Replacement; turn power off; Mode Switching Summary; MANUAL MODE; INSTALLATION; Timer
  • Page 3 – White
  • Page 4 – Motion; Bottom of Sensor; Least Sensitive; TEST AND ADJUSTMENT
  • Page 5 – SPECIFICATIONS; TROUBLESHOOTING GUIDE
  • Page 6 – No Service Parts Available for this Product
  • Page 7 – Características; FUNCIONAMIENTO; Prueba
  • Page 8 – Resumen de las modalidades del interruptor; PRUEBA; INSTALACION; CUIDADO: Para evitar los peligros de incen-; Instalación y Cambio de la Bombilla; apague la energía; Luz de Adorno
  • Page 9 – ADvERTENCIA: Desconecte la energía en el; Instale el Control de Luz; Negro
  • Page 10 – Parte de abajo del detector; Lo menos sensible; PRUEBA Y AJUSTE
  • Page 11 – ESPECIFICACIONES; GUIA DE INvESTIGACION DE AvERIAS
  • Page 12 – de devolver el producto a la tienda.
  • Page 13 – Exigences; FONCTIONNEMENT; Caractéristiques; Contenu de l’emballage; MD; à détecteur
  • Page 14 – Résumé du mode de commutation; Installation et Remplacement de la; Minuterie D
  • Page 15 – Montage de la Commande D’éclairage
  • Page 16 – Bas du détecteur; Le moins sensible; ESSAIS ET RÉGLAGES
  • Page 17 – FICHE TECHNIQUE; GUIDE DE DÉPANNAGE
  • Page 18 – GARANTIE LIMITÉE DE DIX ANS; Exclusions de la garantie -; SERvICE TECHNIQUE; avant de retourner l’article au magasin.; Aucune pièce de rechange n’est disponible pour ce produit.
Loading the manual

© 2008 HeathCo LLC

598-1162-02

D

ual

B

rite

®

Motion

Sensor Light Control

2 Wire

Connectors

Gasket

6 Screws

(3 sizes included)

Light Control

Mounting Strap

Mounting Bolt

2 Bulbs

(installed)

Rubber Plug

Plastic Hanger

Cover

Plate

Sensor

Bulb Holders

Features

• D

ual

Z

one

™ Technology.

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Bulb Saver™ - Extends bulb life by up to 4x standard

bulbs. Lights bulb to full bright in under 2 seconds.

• D

ual

B

rite

®

Timer.

• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

Package Contents

Requirements

• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a qualified
electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

OPERATION

* resets to Auto Mode at dawn.

TEST

TEST

1 5 20

ON-TIME

Off

3 6 Dusk to

Dawn

D

ual

B

rite

®

Put ON-TIME switch
on the sensor bottom
to TEST and the D

ual

-

B

rite

®

switch OFF.

MANUAL MODE

ON-TIME

TEST

1 5 20

... back on.

AUTO

1 Second OFF

then...

Note:

When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

Mode:

On-Time

Works:

Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 20 Min

x

Manual

To Dawn*

x

Accent

3, 6 Hr, to Dawn

x

Meets the ENERGY STAR

®

guidelines

when D

ual

B

rite

®

function is off and

ON-TIME is 1 or 5 minutes.

Model SH-5597

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Bulb Installation and Replacement; turn power off; Mode Switching Summary; MANUAL MODE; INSTALLATION; Timer

2 598-1162-02 For easy installation, select an existing light with a wall switch for replacement.For best performance, mount the fixture about 8 ft. (2.4 m) above the ground. NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance. ❒ Swing the sens...

Page 3 - White

3 598-1162-02 Keep bulbs at least 2" (51 mm) from the sen- sor and 2" (51 mm) from combustibles. Lock Nuts Mount the Light Control ❒ Place the mounting bolt through the front of the junction box cover. Push the small gasket hole over the mounting screw. ❒ Make sure the wire connectors and wi...

Page 4 - Motion; Bottom of Sensor; Least Sensitive; TEST AND ADJUSTMENT

4 598-1162-02 Maximum Maximum Range Coverage Angle MAX MIN RANGE ON-TIME DUAL BRITE™ TEST 1 5 20 MINUTES OFF 3 6 DUSK TO DAWN HOUR BO O S T Motion Motion 8 ft. (2.4 m) 70 ft. 100 ft. (21 m) (30.5 m) Boosted Sensor 240° D ual Z one ™ D ual Z one ™ D ual Z one ™ D ual Z one ™ Bottom of Sensor Avoid ai...

Other Heath Zenith Models

All Heath Zenith Other