Heath Zenith SL-5597 - Manual

Heath Zenith SL-5597

Heath Zenith SL-5597 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – INSTALLATION
  • Page 3 – Bottom of Sensor
  • Page 4 – TROUBLESHOOTING GUIDE; If you experience a problem, follow this guide.
  • Page 5 – FUNCIONAMIENTO; Resumen de las modalidades del interruptor; DUAL BRITETM; PRUEBA
  • Page 6 – INSTALACION
  • Page 7 – ESPECIFICACIONES; Angulo Máximo; PRUEBA Y AJUSTE; Parte de abajo del detector; Lo menos sensible
  • Page 8 – GUIA DE INVESTIGACION DE AVERIAS; Si tiene algún problema siga esta guía.
  • Page 9 – à détecteur; Exigences; FONCTIONNEMENT; Minuterie Dual BriteTM; Résumé du mode de commutation
  • Page 11 – Bas du détecteur; Le moins sensible
  • Page 12 – GUIDE DE DÉPANNAGE; Si vous éprouvez des difficultés, suivre ce guide.
Loading the manual

© 2003 DESA Specialty Products™

598-1038-03

Dual Brite

Motion Sensor
Light Control for
Canadian Tire

Model SL-5597

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Brite™ Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

2 Wire

Connectors

Gasket

6 Screws

(3 sizes included)

Light Control

Requirements

• The Light Control requires 120-volts AC.
• If you want to use the Manual Mode, the control must

be wired through a switch.

Some codes require installation by a qualified

electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Mounting Strap

Mounting Bolt

2 Lamps

(installed)

OPERATION

* resets to Auto Mode at dawn.

TEST

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to

Dawn

DUAL BRITE™

Put ON-TIME switch
on the sensor bottom
to TEST and the Dual
Brite™ switch OFF.

MANUAL MODE

ON-TIME

TEST 1 5 20

... back on.

AUTO

1 Second OFF

then...

Dual Brite™ TIMER

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light
turns on full bright for the ON-TIME (1,5, or 20 minutes)
then returns to dim mode.

Move ON-TIME Switch to

1, 5, or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the ON-
TIME switch in the 1, 5, or 20 position.

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.

Rubber Plug

Plastic Hanger

Cover

Plate

Sensor

Lamp

Holders

This package includes:

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Auto

1, 5, 20 min.

x

Manual

Until Dawn*

x

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION

2 598-1038-03 INSTALLATION For easy installation, select an existing light with a wallswitch for replacement. For under eave installation, the sensor head mustbe rotated as shown in the next two steps for properoperation and to avoid the risk of electrical shock. ❒ Swing the sensor head towards the ...

Page 3 - Bottom of Sensor

3 598-1038-03 SPECIFICATIONS Range . . . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.(30.5 m) with Range Boost.[varies with surroundingtemperature] Sensing Angle . . . . . . . . Up to 240 ° Electrical Load . . . . . . . . Up to 200 Watts Maximum Incandescent (Up to 100Watts Maximum each lampho...

Page 4 - TROUBLESHOOTING GUIDE; If you experience a problem, follow this guide.

4 598-1038-03 POSSIBLE CAUSE 1. A lamp is positioned too close to the sensor or pointed at nearby objectsthat cause heat to trigger the sensor.(Reposition the lamp away from thesensor or nearby objects). 2. Light Control is pointed toward a heat source like an air vent, dryer vent, orbrightly-painte...