Heath Zenith SL-4305 - Manual

Heath Zenith SL-4305

Heath Zenith SL-4305 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – warning: turn power off at circuit
  • Page 3 – recommended grounding method; Other wiring Options; All wiring should be run in accordance with; contact a qualified; When determining the maximum
  • Page 4 – testing; turn on the circuit breaker and light switch.; instaLL Fixture Base tO; SENSITIVITY; Maximum Range
  • Page 5 – sPeciFicatiOns
  • Page 6 – trOuBLeshOOting guide
  • Page 7 – Five year Limited warranty; technicaL service; no service Parts available for this Product
  • Page 8 – PRUEBA; TEST; Prueba; Hasta el
  • Page 9 – desarme eL aParatO de LuZ; instaLe eL sOPOrte universaL; caBLeadO deL aParatO de LuZ; cuidadO: nO retire el conector de
  • Page 10 – Otras opciones de cableado; Todo el cableado debe ser hecho de acuerdo; Póngase; Cuando determine la potencia; método recomendado de conexión a tierra
  • Page 11 – PrueBa; Servicio Técnico; si el cableado; instaLe La Base deL aParatO a; Alcance Máximo
  • Page 12 – Lo menos sensible Lo más sensible; esPeciFicaciOnes
  • Page 13 – guia de investigaciOn de averias
  • Page 14 – garantía Limitada a 5 aÑOs; serviciO tÉcnicO; de devolver el producto a la tienda.
  • Page 15 – rÉsumÉ du mOde de cOmmutatiOn; essai
  • Page 16 – dÉmOntage du Luminaire; instaLLatiOn du suPPOrt de; Branchement des FiLs; attentiOn : ne retireZ Pas le con-
  • Page 17 – méthode de mise à la terre recommandée; autres options de raccordement; Le câblage doit être conforme aux exigences; si vous; Lors de la détermination de la puis-
  • Page 18 – essais; Service; si le raccordement d’un système à; instaLLatiOn du sOcLe du
  • Page 19 – rÉgLage de La ZOne de; Portée maximale
  • Page 21 – garantie LimitÉe de 5 ans; service technique; avant de retourner l’article au magasin.
Loading the manual

Features

• Light comes on when motion is detected.
• Automatically turns light off.
• Photocell keeps the light off during daylight

hours.

requirements

• The light control requires 120 volts AC.
• If you want to use Manual Mode, the control must

be wired through a switch.

some electrical codes require installation by
a qualified electrician.

motion sensing
Porch Light

This package includes:
• Porch Light
• Easy to use Universal Mounting Bracket
• Mounting Hardware
• Wire Nuts
• Lens Shield

SL-4305

© 2007 HeathCo LLC

598-1184-04

OPeratiOn

Note:

When first turned on wait about 1

1

/

2

minutes

for the circuitry to calibrate.

* resets to Auto Mode at dawn.

ON-TIME

Set the ON-TIME switch
on the sensor to TEST.

test 1 5 10 MIN

test

Set ON-TIME switch to
1, 5, or 10 minutes.

autO

ON-TIME Switch at 1, 5, or
10 minutes

... back on.

1 Second OFF

then

...

Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual mode works only with
the ON-TIME switch in the 1, 5,
or 10 position.

mOde switching summary

Flip light switch off
for one second then
back on*

* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

MANUAL MODE

AUTO

TEST

manuaL mOde

ON-TIME

TEST

1 5 10 min

Before installation, record the model number
listed inside the fixture. attach receipt in case
of possible warranty issues.

model number:

Mode:

On-Time

Works: Day Night

test

5 Seconds

x

x

auto

1, 5, or 10 Min

x

manual

To Dawn*

x

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - warning: turn power off at circuit

2 598-1184-04 LO - M - HI SENS ITIVITY ON- TIM E TE ST 1 5 10 MI N LO - M - H I SE NS ITIV ITY ON- TIM E TEST 1 5 10 MIN instaLL universaL mOunting Bracket For best performance, mount the fixture at least 8 feet (2.4 m) above the ground. Fixture Screw (Tightened Finger Tight) Junction Box Universal ...

Page 3 - recommended grounding method; Other wiring Options; All wiring should be run in accordance with; contact a qualified; When determining the maximum

3 598-1184-04 white to white Black to Black One Motion Sensing Light Two Motion Sensing Lights (Working Independently) Black to Black white to white ground to ground Black to Black white to white ground to ground Metal Junction Box Ground Screw recommended grounding method Pigtail (not supplied) Fix...

Page 4 - testing; turn on the circuit breaker and light switch.; instaLL Fixture Base tO; SENSITIVITY; Maximum Range

4 598-1184-04 testing 1. turn on the circuit breaker and light switch. Note: Sensor has a 1 1 / 2 minute warm up period before it will detect motion. When first turned on wait 1 1 / 2 minutes. 2. Set the SENSITIVITY switch to the “M” position and the ON-TIME switch to the TEST posi-tion. 3. Walk thr...