Table of Contents:

  • Page 2 – INSTALLATION; Mode Switching Summary; Flip light; Dimmer Control
  • Page 3 – WIRING; Twist the junction box wires and the; CAUTION: DO NOT connect the RED
  • Page 4 – OPTIONAL WIRING; Wiring Diagram 1 –; Wiring Diagram 1; If the dual master wiring is not
  • Page 5 – COMPLETE THE INSTALLATION; caulk; Model 4193 Glass Installation
  • Page 6 – TESTING; Turn on the circuit breaker and light; Least Sensitive; Avoid aiming the control at:; Maximum Range; Note: Meets the ENERGY STAR
  • Page 7 – SPECIFICATIONS; for maximum wattage; dawn; TROUBLESHOOTING GUIDE
  • Page 8 – FIVE YEAR LIMITED WARRANTY; TECHNICAL SERVICE; If the problem persists, call* for assistance at; No Service Parts Available for this Product
  • Page 9 – FUNCIONAMIENTO; Características; PRUEBA; MODO MANUAL; Prueba; Adorno
  • Page 10 – INSTALACION; Luz de Adorno; * Si se confunde mientras cambia de fases,; Resumen de las modalidades del
  • Page 11 – CABLEADO; CUIDADO: NO conecte el cable ROJO
  • Page 12 – La conexión inadecuada; CONEXION ALTERNA; Diagrama de Cableado 1 –; Cuando prepare una conexión para controlar un aparato de luz; Diagrama de Cableado 2 –; Cuando prepare una conexión para controlar otro aparato de; Diagrama de Cableado 1
  • Page 13 – COMPLETE LA INSTALACION; una; Instalación del vidrio del Modelo
  • Page 14 – Alcance Máximo; Evite apuntar el control hacia:; Lo menos sensible
  • Page 15 – GUIA DE INVESTIGACION DE AVERIAS; ESPECIFICACIONES
  • Page 16 – GARANTÍA LIMITADA A 5 AÑOS; SERVICIO TÉCNICO; antes de devolver el producto a la tienda.; Si el problema continúa, llame al; No hay piezas de servicio disponibles para este producto.
  • Page 17 – FONCTIONNEMENT; ESSAI; Essai
  • Page 18 – MINUTERIE D; Résumé du mode de commutation; mentation au disjoncteur ou au fusible.
  • Page 19 – Méthode de mise à la terre recommandée; CÂBLAGE; Contactez un électricien; Une lanterne à détecteur de mouvement; Torsadez ensemble les fils de la boîte
  • Page 20 – Diagramme de câblage 1; CÂBLAGE FACULTATIF; Diagramme de câblage 1 –; Câblage d’un luminaire standard : Dénudez le fil rouge du; Diagramme de câblage 2 –; Câblage d’un autre luminaire à détecteur de mouvement
  • Page 21 – COMPLÉTEZ L'INSTALLATION; une; Installation des panneaux de
  • Page 22 – ESSAIS; Le moins sensible
  • Page 23 – GUIDE DE DÉPANNAGE; priorité manuelle; FICHE TECHNIQUE
  • Page 24 – GARANTIE LIMITÉE DE 5 ANS; Exclusions de la garantie -; SERVICE TECHNIQUE; l’aide avant de retourner l’article au magasin.
Loading the manual

Motion Sensing
Diecast Lantern

SL-4190 Series

Features

• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
• Photocell keeps the light off during daylight

hours.

Requirements

• The light control requires 120 volts AC.
• If you want to use Manual Mode, the control

must be wired through a switch.

Some codes require installation by a
qualified electrician.

© 2007 HeathCo LLC

595-5628-08

OPERATION

* resets to Auto Mode at dawn.

Set the ON-TIME switch
on the bottom of the
cover plate to

TEST.

TEST

1 5 10 MIN

Set ON-TIME switch to
1, 5, or 10 minutes.

1 Second

OFF then...

Manual mode only works at
night because daylight re-
turns the sensor to AUTO.
Flip the light switch off for
one second then back on to
toggle between AUTO and
MANUAL MODE.
Manual mode works only
with the ON-TIME switch in
the 1, 5, or 10 position.

... back on.

This package includes:
• Lantern
• Easy to use universal mounting bracket

(X-Bar)

• Mounting hardware
• Wire nuts

Note:

When first turned on wait about 1

1

/

2

minutes for the circuitry to calibrate.

TEST

AUTO

MANUAL MODE

TEST

1 5 10 MIN

Mode:

On-Time

Works: Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

x

Manual

To Dawn*

x

Accent

3, 6 Hr, to Dawn

x

Meets the ENERGY STAR

®

guidelines when D

ual

B

rite

®

function is off.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; Mode Switching Summary; Flip light; Dimmer Control

2 595-5628-08 INSTALLATION For best performance, mount the fixture about 6 feet (1.8 m) above the ground. 1. Remove two nuts. 2. Remove X-Bar. Junction Box 5. Attach X-Bar to junction box Due to the size and weight of the fixture, you may find it helpful to have an assistant hold the fixture in plac...

Page 3 - WIRING; Twist the junction box wires and the; CAUTION: DO NOT connect the RED

3 595-5628-08 Recommended Grounding Method Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the “pigtail” with the GND screw on the X-bar. Black to black White to white WIR...

Page 4 - OPTIONAL WIRING; Wiring Diagram 1 –; Wiring Diagram 1; If the dual master wiring is not

4 595-5628-08 OPTIONAL WIRING This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100 Watts, 260 Watts of additional load may be controlled by this sensor.When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture...