- Page 2 – Remove the existing light fixture.; Wire the Light Control; WARNING: Turn power off at circuit breaker; INSTALLATION; Mode Switching Summary; MANUAL MODE; CAUTION: Risk of fire. This fixture is designed
- Page 3 – Mount the Light Control; caulk the wall plate and mounting; Bulb Installation and Re-lamping; turn power off and let the fixture
- Page 4 – TEST AND ADJUSTMENT; Bottom of Sensor; Maximum Range; SPECIFICATIONS
- Page 5 – TROUBLESHOOTING GUIDE
- Page 6 – TECHNICAL SERvICE; No Service Parts Available for this Product
- Page 7 – Requisitos; Características; FUNCIONAMIENTO; Prueba
- Page 8 – Conecte el control de luz; INSTALACION; PRECAUCIóN: Riesgo de incendio. Esta; Resumen de las modalidades del; PRUEBA; NOTA: Si el aparato está instalado a
- Page 9 – Instalación y cambio de bombilla; apague la energía y; Instale el control de luz; calafatee
- Page 10 – PRUEBA Y AJUSTE; Parte de abajo del detector; Lo menos sensible
- Page 11 – GUIA DE INvESTIGACION DE AvERIAS
- Page 12 – GARANTÍA LIMITADA A 10 AÑOS; SERvICIO TÉCNICO; de devolver el producto a la tienda.; No hay piezas de servicio disponibles para este producto.
- Page 13 – Caractéristiques; FONCTIONNEMENT; Exigences
- Page 14 – MISE EN GARDE : Coupez l’alimentation au; Résumé du mode de commutation; ATTENTION : Risque d’incendie - Cet appareil
- Page 15 – calfeutrer; Installation et remplacement de; tion et laisser refroidir le luminaire.
- Page 16 – ESSAIS ET RÉGLAGES; Bas du détecteur; Portée maximale
- Page 17 – CAUSE POSSIBLE
- Page 18 – GARANTIE LIMITÉE DE 10 ANS; SERvICE TECHNIQUE; avant de retourner l’article au magasin.
Cover
Plate
Sensor
Light Control
Cover Plate
Gasket
© 2008 HeathCo LLC
598-1343-00
Requirements
• The light control requires 120-volts AC.
• This fixture is designed for wall mounting only.
• If you want to use Manual Override, the control must
be wired through a switch.
•
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at Home Centers
and Electrical Supply Stores.
S-hook
1 Halogen
Lamp
Model SH-5311
3 Wire
Connectors
6 Screws
(3 sizes included)
This package includes:
OPERATION
* resets to Auto Mode at dawn.
TEST
10 5 1
TEST
ON-TIME
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
MANUAL MODE
ON-TIME
10 5 1 TEST
... back on.
AUTO
1 Second OFF
then...
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Normal
1, 5, 10 min.
x
Manual
Until Dawn*
x
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Bulb Saver™ - Extends bulb life by up to 4x standard
bulbs. Lights bulb to full bright in under 2 seconds.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Professional Motion Sensor
Quartz Security Light
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 598-1343-00 Cover Plate Gasket ❒ Drill out the holes if needed to mount the backplate to the junction box. White to White ❒ Attach the lamp arm to the backplate arm and secure with the long bolt. Note: When tightening the arm screw, pull on the wires to make sure the wires are not pinched by the j...
3 598-1343-00 +/- 4° Mount the Light Control ❒ Align the light control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws. ❒ If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone wea...
4 598-1343-00 TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has about 1 1 / 2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1 / 2 minutes. ❒ Turn the RANGE control to the mid position (halfway between MIN and MAX) and the O...