Heath Zenith MSL360FWPB - Manual

Heath Zenith MSL360FWPB

Heath Zenith MSL360FWPB – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – INSTALLATION; NOTE: If fixture is mounted; Mode Switching Summary; MANUAL MODE; Wall Mount
  • Page 3 – Mount the Light Control; Black to Black; Wire the Light Control; WARNING: Turn power off at circuit breaker
  • Page 4 – Bottom of Sensor; Motion
  • Page 5 – TROUBLESHOOTING GUIDE; TWO YEAR LIMITED WARRANTY; TECHNICAL SERvICE; No Service Parts Available for this Product
  • Page 6 – Requisitos; Características; FUNCIONAMIENTO; Prueba
  • Page 7 – Resumen de las modalidades del; PRUEBA; INSTALACION; NOTA: Si el aparato está instalado a; Montaje en pared
  • Page 8 – Instale El Control De Luz; Blanco a blanco; Conecte El Control De Luz; ADvERTENCIA: Desconecte la energía en el
  • Page 9 – PRUEBA Y AJUSTE; Parte de abajo del detector
  • Page 10 – GUIA DE INvESTIGACION DE AvERIAS; ESPECIFICACIONES
  • Page 11 – GARANTÍA LIMITADA A 2 AÑOS; SERvICIO TÉCNICO; producto a la tienda.
  • Page 12 – Exigences; Caractéristiques; FONCTIONNEMENT
  • Page 13 – Résumé du mode de commutation; Montage mural; Faites ensuite tourner le capteur de 180 °de sorte
  • Page 14 – MISE EN GARDE : Coupez l’alimentation au
  • Page 15 – ESSAIS ET RÉGLAGES; Bas du détecteur; FICHE TECHNIQUE
  • Page 16 – GUIDE DE DÉPANNAGE; GARANTIE LIMITÉE DE 2 ANS; veuillez conserver le reçu portant la date d'achat vous; SERvICE TECHNIQUE; retourner l’article au magasin.
Loading the manual

Pentamark LLC

598-1351-01

Requirements

• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a qualified
electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Light Control

Sensors

Cover

Plate

Lamp Holders

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

Plastic Hanger

Rubber Plug

Gasket

Mounting Strap

Mounting Bolt

3 Wire

Connectors

This package includes:

6 Screws

(3 sizes included)

OPERATION

* resets to Auto Mode at dawn.

TEST

10 5 1

TEST

ON-TIME

Put the ON-TIME switch on the
bottom of the sensors in the TEST
position.

MANUAL MODE

ON-TIME

10 5 1 TEST

... back on.

AUTO

1 Second OFF

then...

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sen-
sors to AUTO.

Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Put the ON-TIME switch in the
1, 5, or 10 minute position.

Mode:

On-Time:

Works:

Day

Night

Test

5 Seconds

x

x

Normal

1, 5, 10 min.

x

Manual

Until Dawn*

x

Model MSL360FWPB

Motion Sensor
Light Control

Meets the ENERGY STAR

®

guidelines

when used with 120 W Max bulbs.

2 Shells

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; NOTE: If fixture is mounted; Mode Switching Summary; MANUAL MODE; Wall Mount

2 598-1351-01 INSTALLATION For easy installation, select an existing light operated by a wall switch for replacement.For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensors down will reduce coverage dist...

Page 3 - Mount the Light Control; Black to Black; Wire the Light Control; WARNING: Turn power off at circuit breaker

3 598-1351-01 Mount the Light Control ❒ Align the light control cover plate and cover plate gasket. Secure with the mounting bolt. ❒ Align the three slots in the decorative shell with the lamp holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell. Lock Nut To avoid ...

Page 4 - Bottom of Sensor; Motion

4 598-1351-01 TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. ❒ For each sensor, loosen the clamp screw in the sensor ball joint and gently rotate the sen-sor. ❒ Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times wh...