Heath Zenith CB-2011 - Manual

Heath Zenith CB-2011

Heath Zenith CB-2011 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – INSTALLATION; Wall Mount
  • Page 3 – TEST AND ADJUSTMENT; Bottom of Sensor; SPECIFICATIONS
  • Page 4 – TROUBLESHOOTING GUIDE; No Service Parts Available for this Product; TECHNICAL SERVICE
Loading the manual

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Auto

1, 5, 20 min.

x

Manual

Until Dawn*

x

OPERATION

Model CB-2011

Motion Sensor
Light Control with
Protective Lamp
Shields

© 2003 DESA Specialty Products™

598-1111-01

* resets to Auto Mode at dawn.

TEST

Light Control

Sensor

Cover

Plate

Lamp

Holders

6 Screws

(3 sizes included)

Gasket

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.

Requirements

• The Light Control requires 120-volts AC.
• If you want to use the Manual Mode, the control must

be wired through a switch.

Some codes require installation by a qualified

electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

TEST 1 5 20

ON-TIME

Put ON-TIME switch on the sensor
bottom to TEST.

MANUAL MODE

ON-TIME

TEST 1 5 20

... back on.

AUTO

1 Second OFF

then...

Move ON-TIME Switch to

1, 5 or 20 minutes

Mode Switching Summary

Flip light switch off for

one second then back

on*

MANUAL MODE

AUTO

TEST

Note:

When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

* If you get confused while switching modes, turn the

power off for one minute, then back on.

After the

calibration time the control will be in the AUTO mode.

Mounting Bolt

Mounting Strap

Rubber Plug

Plastic Hanger

2 PAR Lamps

2 Wire

Connectors

This package includes:

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; Wall Mount

598-1111-01 2 INSTALLATION For easy installation, select an existing light with a wallswitch for replacement. W IRE THE L IGHT C ONTROL . ❒ Turn power off at the fuse or circuit breaker. ❒ Remove the existing light fixture. ❒ Install the mounting strap as shown using twoscrews that fit your junction...

Page 3 - TEST AND ADJUSTMENT; Bottom of Sensor; SPECIFICATIONS

598-1111-01 3 Motion Motion TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1 / 2 minute warm up period before it will detect motion. When first turned on or when switching modes wait 1 1 / 2 minutes. Bottom of Sensor Avoid aiming the sensor at: • Objects tha...

Page 4 - TROUBLESHOOTING GUIDE; No Service Parts Available for this Product; TECHNICAL SERVICE

598-1111-01 4 POSSIBLE CAUSE 1. A flood lamp is positioned too close to the sensor or pointed at nearby ob-jects that cause heat to trigger thesensor. (Reposition the lamp away from the sensor or nearby objects.) 2. Light Control is pointed toward a heat source like an air vent, dryer vent, orbright...

Other Heath Zenith Models

All Heath Zenith Other