Heath Zenith 598-1041-04 - Manual

Heath Zenith 598-1041-04

Heath Zenith 598-1041-04 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – INSTALLATION; junction box; WIRING; CAUTION: If you are not controlling stan-
  • Page 3 – NOTE: All wiring between fixtures should be; OPTIONAL WIRING; Slide the fixture onto
  • Page 4 – TESTING; SPECIFICATIONS; Sensor has a 1; Avoid locations that will cause the; • Objects that change temperature rapidly,; • Areas where pets or traffic may trigger the
  • Page 5 – TROUBLESHOOTING GUIDE; See your Canadian Tire retailer for warranty information.; No Service Parts Available for this Product
  • Page 6 – FUNCIONAMIENTO; Características; Requisitos; PRUEBA
  • Page 7 – INSTALACION; CABLEADO; CUIDADO: Si no está controlando aparatos; Blanco to blanco
  • Page 8 – CONEXION ALTERNA; NOTA: Todo el cableado entre los aparatos; COMPLETE LA
  • Page 9 – NOTA: El detector tiene un período de cerca; ESPECIFICACIONES; Evite lugares que obliguen al
  • Page 10 – GUIA DE INVESTIGACION DE AVERIAS; No hay piezas de servicio disponibles para este producto
  • Page 11 – Exigences; FONCTIONNEMENT; PRIORITÉ MANUELLE
  • Page 12 – AVERTISSEMENT: Si votre commande à; CÂBLAGE
  • Page 13 – NOTE: Le câblage entre les appareils; COMPLÉTEZ; Glissez le luminaire; CÂBLAGE FACULTATIF
  • Page 14 – ESSAIS; FICHE TECHNIQUE; NOTE: Le capteur doit se réchauffer 1; Éviter de pointer l’appareil:
  • Page 15 – GUIDE DE DÉPANNAGE; retourner le produit chez le détaillant.; Aucune pièce de rechange n’est disponible pour ce produit
Loading the manual

Test

5 Sec

x

x

Auto

1, 5 or 10 Min

x

Manual

To Dawn*

x

Accent

3,6 Hr, to Dawn

x

Mode:

On-Time

Works: Day Night

Motion Sensing
Cast Aluminum
Lantern for
Canadian Tire

Features

• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
• Photocell keeps the light off during day-

light hours.

Requirements

• The Light Control requires 120 volts AC.
• If you want to use Manual Mode, the con-

trol must be wired through a switch.

Some codes require installation by a

qualified electrician.

© 2004 DESA Specialty Products™

598-1041-04

OPERATION

* resets to Auto Mode at dawn.

Set the ON-TIME switch
on the bottom of the cover
plate to TEST.

TEST

TEST 1 5 10 MIN

AUTO

Set ON-TIME switch to 1,
5, or 10 minutes.

TEST 1 5 10 MIN

MANUAL MODE

1 Second

OFF

then...

Manual mode only works at
night because daylight returns
the sensor to AUTO.

Flip the light switch off for
one second then back on to
toggle between AUTO and
MANUAL MODE.

Manual mode works only with
the ON-TIME switch in the 1,
5, or 10 position.

... back on.

Mode Switching Summary

Dual Brite

Dimmer Control

Light comes on half bright for selected time
after dusk (3 hr., 6 hr., until dawn). If motion
is sensed, the light turns on full bright for the
ON-TIME (1, 5, or 10 minutes) then returns
to dim mode.

This package includes:
• Lantern
• Easy to use universal mounting bracket

(X-Bar)

• Mounting hardware
• Wire nuts

ON-TIME

Switch at 1,

5, or 10

minutes

Flip light

switch off for

one second

then back on*

* If you get confused while switching modes,

turn the power off for one minute, then back on.
After the calibration time the control will be in
the AUTO mode.

MANUAL MODE

AUTO

TEST

Note: When first turned on wait about 1

1

/

2

minutes for the circuitry to calibrate.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; junction box; WIRING; CAUTION: If you are not controlling stan-

2 598-1041-04 INSTALLATION For best performance, mount the fixture about1.8 meters above the ground. ❒ Turn power off at the circuit breakeror fuse. 1. Remove two nuts. 2. Remove X-Bar. ; ; ; ; ; ; ; ; Junction Box 5. Attach X-Bar to junction box Due to the size and weight of the fixture, youmay fin...

Page 3 - NOTE: All wiring between fixtures should be; OPTIONAL WIRING; Slide the fixture onto

3 598-1041-04 ❒ When wiring to additional standardfixture only: Strip the motion sensor'sred wire and connect to the standardlight's black wire. Connect all white wirestogether. Total fixture ratings must notexceed 360W (3.0 A.). NOTE: All wiring between fixtures should be run in accordance with the...

Page 4 - TESTING; SPECIFICATIONS; Sensor has a 1; Avoid locations that will cause the; • Objects that change temperature rapidly,; • Areas where pets or traffic may trigger the

4 598-1041-04 TESTING ❒ Turn on the circuit breaker and lightswitch. The detector is less sensitive to motion directlytowards it and more sensitive to across motion. Motion Motion Least Sensitive Most Sensitive OFF 3 6 DUSK TO HOUR DAWN TEST 1 5 10 MIN ❒ Set the amount of time after dusk youwant the...