Heath Zenith 5598 - Manual
Heath Zenith 5598 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – cautiOn: DO nOt connect the reD wire; Optional Wiring; contact a qualified electrician
- Page 3 – recommended grounding Method; Master; OptiOnaL Wiring; and void your warranty.
- Page 4 – testing anD aDjustMents; turn on the circuit breaker and light switch.; Note: Sensor has a 1; Maximum Range; FinaL asseMBLy
- Page 5 – Note: When first turned on wait about 1; Least Sensitive; OperatiOn; test; MODe sWitching suMMary
- Page 6 – trOuBLeshOOting guiDe; If you experience a problem, follow this guide.; technicaL service; no service parts available for this product
- Page 7 – caracterÍsticas; Faroles de Metal
- Page 8 – cuiDaDO: nO conecte el cable rOjO; Conexion; póngase en contacto
- Page 9 – Método recomendado de conexión a tierra; Maestra; cOneXiOn aLterna; negro de la luz estándar. Conecte todos los alambres blancos.
- Page 10 – prueBas y ajustes; conecte el disyuntor y el interruptor de la; Alcance Máximo
- Page 11 – prueba; Hasta el; Lo menos sensible; * Si se confunde mientras cambia de fases, apague
- Page 12 – especiFicaciOnes; de luz incandescente; guia De investigaciOn De averias; Si tiene algún problema por favor siga esta guía.; MANUAL
- Page 13 – serviciO tÉcnicO; devolver el producto a la tienda.
- Page 14 – caractÉristiques; • S’allume automatiquement lors de la détection d’un; DÉBaLLage; • La commande d’éclairage exige du courant 120 V; asseMBLage De La Lanterne; Insérez doucement les deux pièces l’une dans; Lanterne en métal
- Page 15 – avertisseMent: ne pas raccorder le fil; Câblage Facultatif; contactez un
- Page 16 – Méthode de mise à la terre recommandée; Maître; cÂBLage FacuLtatiF
- Page 17 – essais et rÉgLages; Note : Le capteur exige 1; Portée maximale; asseMBLage FinaL
- Page 18 – FOnctiOnneMent; * Revient au mode automatique au lever du soleil.; essai; secondes; auto; Le moins sensible; rÉsuMÉ Du MODe De cOMMutatiOn; priOritÉ ManueLLe; rÉgLage De La ZOne De; • Appareil de climatisation
- Page 19 – guiDe De DÉpannage; Si vous éprouvez des difficultés, suivez ce guide.; Fiche technique; maximum
- Page 20 – service technique; avant de retourner l’article au magasin.; garantie LiMitÉe De 5 ans
Features
• Automatically comes on when motion is detected.
• Automatically turns light off.
• Photocell keeps the light off during daylight
hours.
© 2007 DESA Specialty Products™
598-1314-00
unpacking
Be sure to remove all contents from packaging and
verify all items are present before assembling this light
fixture. This package includes the following items:
• Lantern (Includes: Top Cover, Glass Fixture, Fixture
Base)
• Universal mounting bracket (X-Bar)
• Mounting hardware
• Wire nuts
• Owner’s Manual
Before installation, record the model number
listed inside the fixture. attach receipt in case
of possible warranty issues.
Model number:
requireMents
• The Light Control requires 120 volts AC.
• If you want to use Manual Mode, the control must
be wired through a switch.
•
some electrical codes require installation by a
qualified electrician.
Motion sensing
Diecast Metal Lantern
Lantern asseMBLy
1. Place glass fixture onto base assembly.
2. Line up the arrow on the bottom of glass fixture
with the arrow on the fixture base (see illustration
below).
Glass Fixture
Arrows
Fixture
Base
Glass Fixture
Fixture Base
3. Gently push the two pieces together and rotate
the glass fixture 90° as shown below.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 598-1314-00 Wiring instaLLatiOn For best performance, mount the fixture about 6 feet (1.8 m) above the ground.1. Remove two decorative nuts.2. Remove X-Bar.3. Tighten mounting screws on X-Bar finger tight.4. Attach X-Bar to junction box. Junction Box X-Bar Decorative Nut Lantern Lantern Mounting S...
3 598-1314-00 recommended grounding Method Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire con-nector. Secure the other end of the “pigtail” with the GND screw on the X-bar. Black to black White to white Wi...
4 598-1314-00 testing anD aDjustMents 1. turn on the circuit breaker and light switch. Note: Sensor has a 1 1 / 2 minute warm up period before it will detect motion. When first turned on wait 1 1 / 2 minutes. 2. Set: ON-TIME switch to TEST SENSITIVITY dial to Midway 3. Walk through the coverage area...