- Page 4 – TROUBLESHOOTING GUIDE; before returning product to store.; No Service Parts Available for this Product; TEN YEAR LIMITED WARRANTY
- Page 5 – FUNCIONAMIENTO; Requisitos; Resumen de las modalidades del interruptor; PRUEBA; Prueba
- Page 6 – Instalación y cambio de bombilla; Instale el control de luz; INSTALACION; Conecte el control de luz
- Page 7 – Lo menos sensible; Alcance Máximo
- Page 8 – GUIA DE INvESTIGACION DE AvERIAS; pedir ayuda antes de devolver el producto a la tienda.; No hay piezas de servicio disponibles para este producto.; GARANTÍA LIMITADA A 10 AÑOS
- Page 9 – Caractéristiques; FONCTIONNEMENT; PRIORITÉ MANUELLE
- Page 10 – Montage De La Commande D’Éclairage; Installation et remplacement de
- Page 11 – Le moins sensible; Portée maximale
- Page 12 – GUIDE DE DÉPANNAGE; de l’aide avant de retourner l’article au magasin.; Aucune pièce de rechange n’est disponible pour ce produit.; GARANTIE LIMITÉE DE 10 ANS
Professional Motion
Sensor Quartz Security
Light
Model 5310
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Cover
Plate
Sensor
3 Wire Nuts
6 Screws
(3 sizes)
Light Control
Cover Plate
Gasket
© 2007 HeathCo LLC
598-1323-01
Halogen
Bulb
Requirements
• The light control requires 120-volts AC.
• This fixture is designed for wall mounting only.
• If you want to use Manual Override, the control must
be wired through a switch.
•
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at Home Centers
and Electrical Supply Stores.
S-hook
OPERATION
* resets to Auto Mode at dawn.
TEST
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
MANUAL MODE
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch
to 1, 5, or 10 minutes
Mode Switching Summary
Flip light switch
off for one second
then back on*
MANUAL MODE
AUTO
TEST
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
This package includes:
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Normal
1, 5, 10 min.
x
Manual
Until Dawn*
x
10 5 1
TEST
ON-TIME
ON-TIME
10 5 1
TEST
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 598-1323-01 Mount the Light Control ❒ Align the light control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws. ❒ If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather se...
3 598-1323-01 SPECIFICATIONS Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature] Sensing Angle . . . . . . . Up to 180°Electrical Load . . . . . . . Up to 500 Watt Maximum Incandescent Power Requirements . . 120 VAC, 60 HzOperating Modes . . . . . TEST, AUTO and...
4 598-1323-01 POSSIBLE CAUSE 1. The lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor. (Reposition the lamp away from the sensor or nearby objects.) 2. Sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted...