Heath Zenith 2LBN3 - Manual
Heath Zenith 2LBN3 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION
- Page 3 – SPECIFICATIONS; Maximum; TEST AND ADJUSTMENT
- Page 4 – TROUBLESHOOTING GUIDE; YEAR LIMITED WARRANTY:
- Page 5 – Repuesto D; Para el; Características; FUNCIONAMIENTO; Resumen de las modalidades del interruptor; PRUEBA; Prueba; Manual de Instrucciones y Partes
- Page 6 – LUZ DE DOS NIVELES (D; Conecte el Control de Luz; alambre blanco del detector es neutro.; Instale el Control de Luz; INSTALACION; ADVERTENCIA: Desconecte la energía en el
- Page 7 – Angulo de; ESPECIFICACIONES
- Page 8 – GUIA DE INVESTIGACION DE AVERIAS
- Page 9 – Caractéristiques; Exigences; FONCTIONNEMENT; Résumé du mode de commutation; Mode d’emploi et guide des pièces
- Page 10 – Minuterie D
- Page 11 – Bas du détecteur; Le moins sensible; ESSAIS ET RÉGLAGES
- Page 12 – FICHE TECHNIQUE; GUIDE DE DÉPANNAGE; GARANTIE LIMITÉE D’UN AN :
D
ual
B
rite
®
Replacement
Sensor Head
Features
• D
ual
Z
one
™ Technology.
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Patented D
ual
B
rite
®
Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Requirements
• Not for use with fluorescent lights.
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
•
Install sensor in accordance with local codes.
598-1115-04
LPG-5316
OPERATION
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
TEST
TEST
1 5 20
ON-TIME
Off
3 6 Dusk to
Dawn
D
ual
B
rite
®
Put ON-TIME switch
on the sensor bottom
to TEST and the D
ual
-
B
rite
®
switch OFF.
D
ual
B
rite
®
TIMER
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or 20
minutes) then returns to dim mode.
MANUAL MODE
ON-TIME
TEST
1 5 20
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch to
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
®
Operating Instructions & Parts Manual
2LBN3, 2LBN4
HEA 011
Printed in China
09/07
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or main-
tain the product described. Protect yourself and others by observing all safety information. Failure to comply
could result in personal injury and/or property damage! Save these instructions for future reference.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 598-1115-04 Wire the Light Control These instructions show the sensor wired to floodlamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the switched “hot” wire. The lighting load (500 Watts, 4.2 A max. incandescent only) is placed across the white and red wires. ...
3 598-1115-04 SPECIFICATIONS Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [ v a r i e s w i t h s u r r o u n d i n g temperature] Vertical Range . . . . . . Up to 15 ft. (4.6 m)Sensing Angle . . . . . . Up to 240° horizontal. Up to 80° Vertical Electrical Load . ...
4 598-1115-04 POSSIBLE CAUSE 1. A bulb is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor. (Reposition the bulb away from the sensor or nearby objects). 2. Sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted h...