Page 2 - INSTALLATION

2 598-1115-04 Wire the Light Control These instructions show the sensor wired to floodlamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the switched “hot” wire. The lighting load (500 Watts, 4.2 A max. incandescent only) is placed across the white and red wires. ...

Page 3 - SPECIFICATIONS; Maximum; TEST AND ADJUSTMENT

3 598-1115-04 SPECIFICATIONS Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [ v a r i e s w i t h s u r r o u n d i n g temperature] Vertical Range . . . . . . Up to 15 ft. (4.6 m)Sensing Angle . . . . . . Up to 240° horizontal. Up to 80° Vertical Electrical Load . ...

Page 4 - TROUBLESHOOTING GUIDE; YEAR LIMITED WARRANTY:

4 598-1115-04 POSSIBLE CAUSE 1. A bulb is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor. (Reposition the bulb away from the sensor or nearby objects). 2. Sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted h...