Heath Zenith 2LBN2 - Manual

Heath Zenith 2LBN2

Heath Zenith 2LBN2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Bulb Replacement
  • Page 3 – OPERATION; TEST; Maximum; TEST AND ADJUSTMENT; Move ON-TIME Switch to; Mode Switching Summary; Flip light switch off; MANUAL MODE
  • Page 4 – Final Settings
  • Page 5 – TROUBLESHOOTING GUIDE; YEAR LIMITED WARRANTY:
  • Page 6 – Manual de Instrucciones y Partes; Requerimientos
  • Page 7 – Cambio de la bombilla
  • Page 8 – MODO MANUAL; AUTOMÁTICO; FUNCIONAMIENTO; Angulo de; PRUEBA Y AJUSTE; Mueva el interruptor de; Resumen de las modalidades del interruptor; PRUEBA
  • Page 9 – Calibraciones finales
  • Page 10 – Tabla de Análisis de Averías
  • Page 11 – Exigences; Mode d’emploi et guide des pièces
  • Page 12 – INSTALLATION; Câblage De La Commande D’Éclairage; Montage De La Commande D’Éclairage; Remplacement de la lampe
  • Page 13 – ESSAIS ET RÉGLAGES; FONCTIONNEMENT; Portée maximale; PRIORITÉ MANUELLE; Résumé du mode de commutation
  • Page 14 – Le moins sensible; Derniers Réglages
  • Page 15 – GUIDE DE DÉPANNAGE; GARANTIE LIMITÉE D’UN AN :
Loading the manual

Motion Sensor Quartz

Security Light

Requirements

• The light control requires 120-volts AC.
• This fixture is designed for wall mounting only.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a qualified
electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

• The backplate has knockouts so the sensor can be

mounted on most junction boxes.

• In some applications a universal adaptor plate may

be needed. Adaptors are available at Home Centers
and Electrical Supply Stores.

®

This package includes:

1 Light control

1 Gasket
1 Halogen Bulb
1 S-hook
6 Screws (3 sizes)
3 Wire connectors

Additional Items needed:
• Screwdriver
• Pliers to tighten locknut
• Ladder

Operating Instructions & Parts Manual

2LBN2

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost.
[ v a r i e s w i t h s u r r o u n d i n g
temperature]

Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°

Vertical

Electrical Load . . . . . . Up to 500 Watts Maximum In-

candescent

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 20 minutes
Replacement Lamp . . T3 500 Watt (or less) halogen

120 VAC

D

ual

B

rite

®

Timer . . . . OFF, 3, 6 hours, Dusk-to-Dawn

598-1114-04

HEA 010
Printed in China
09/07

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or main-
tain the product described. Protect yourself and others by observing all safety information. Failure to comply
could result in personal injury and/or property damage! Save these instructions for future reference.

NOTE: D

ual

Z

one

™ adds a zone of detection under

the motion sensor. D

ual

Z

one

™ requires no additional

adjustment and operates in conjuction with the for-
ward-looking sensor.

LPG-5311

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Bulb Replacement

-2- 598-1114-04 INSTALLATION Wire the Light Control WARNING: Turn power off at the fuse or circuit breaker.1. Remove the existing light fixture. 2. The S-hook can be used to hold the fixture while wiring. The small end of the hook can be inserted into a hole in the junction box. The large end goes a...

Page 3 - OPERATION; TEST; Maximum; TEST AND ADJUSTMENT; Move ON-TIME Switch to; Mode Switching Summary; Flip light switch off; MANUAL MODE

-3- 598-1114-04 Bottom of Sensor IMPORTANT Avoid aiming the sensor at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the control. • Nearby large, light-colored objects ...

Page 4 - Final Settings

-4- 598-1114-04 3. Loosen the clamp screw in the sensor ball joint and gently rotate the sensor. 4. Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area. Clamp Screw Ball Joint Aim Sensor Down for Short Co...

Other Heath Zenith Models

All Heath Zenith Other