1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – Dimmer cOntrOL; warning: turn power off at circuit
  • Page 3 – recommended grounding method; Other wiring Options; contact a qualified
  • Page 4 – testing; turn on the circuit breaker and light switch.; Note: Sensor has a 1; if the dual controlled wiring is not done; instaLL Fixture Base tO; DualBrite; SENSITIVITY; Maximum Range
  • Page 5 – sPeciFicatiOns; aDJustment OF cOverage
  • Page 6 – trOuBLeshOOting guiDe; Five year LimiteD warranty; technicaL service; If the problem persists, call* for assistance at; no service Parts available for this Product
  • Page 7 – test; TEST; Prueba; el amanecer; manual; Hasta el
  • Page 8 – caBLeaDO DeL aParatO De LuZ; cuiDaDO: nO retire el conector de; Desarme eL aParatO De LuZ; cOntrOL reDuctOr D; aDvertencia: Desconecte la energía
  • Page 9 – método recomendado de conexión a tierra; Otras opciones de cableado; Póngase
  • Page 10 – PrueBa; Nota: El detector tiene un período de cerca de 1; si el cableado; instaLe La Base DeL aParatO a; Alcance Máximo
  • Page 11 – esPeciFicaciOnes; reguLaciÓn DeL Área De; Lo menos sensible Lo más sensible
  • Page 12 – guia De investigaciOn De averias; de devolver el producto a la tienda.; Si el problema continúa, llame al; no hay piezas de servicio disponibles para este producto.
  • Page 13 – garantía LimitaDa a 5 aÑOs
  • Page 14 – Lampe d’entrée
  • Page 15 – Branchement Des FiLs; attentiOn : ne retireZ Pas le con-; DÉmOntage Du Luminaire; rhÉOstat D; mise en garDe : coupez l’alimentation
  • Page 16 – méthode de mise à la terre recommandée; autres options de raccordement; si vous
  • Page 17 – essais; Note : Le capteur doit se réchauffer 1; si le raccordement d’un système à; instaLLatiOn Du sOcLe Du; puissance maximum de 25 w chacune)
  • Page 18 – rÉgLage De La ZOne De; Portée maximale
  • Page 19 – Fiche technique; guiDe De DÉPannage
  • Page 20 – garantie LimitÉe De 5 ans; exclusions de la garantie -; service technique; avant de retourner l’article au magasin.
Loading the manual

Features

• Light comes on when motion is detected.
• Automatically turns light off.
• Half power Accent lighting.
• Photocell keeps the light off during daylight

hours.

requirements

• The light control requires 120 volts AC.
• If you want to use Manual Mode, the control must

be wired through a switch.

some electrical codes require installation by
a qualified electrician.

Diecast motion
sensing Porch Light

This package includes:
• Porch Light
• Easy to use Universal Mounting Bracket
• Mounting Hardware
• Wire Nuts
• Lens Shield

SL-4300

© 2007 HeathCo LLC

598-1183-03

Mode:

On-Time

Works: Day Night

test

5 Sec

x

x

auto/

1, 5, or 10 min

x

accent

Off, 3, 6 Hr, to Dawn

x

manual

Until Dawn*

x

OPeratiOn

Note: When first turned on wait about 1

1

/

2

minutes

for the circuitry to calibrate.

* resets to Auto Mode at dawn.

ON-TIME

test

1 5 10 MIN

test

Set ON-TIME switch to
1, 5, or 10 minutes.

autO

ON-TIME Switch at 1, 5, or
10 minutes

... back on.

1 Second OFF
then...

Manual mode only works at
night because daylight returns
the sensor to AUTO.
Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual mode works only with
the ON-TIME switch in the 1,
5, or 10 position.

mODe switching summary

Flip light switch off
for one second then
back on*

* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

MANUAL MODE

AUTO

TEST

manuaL mODe

ON-TIME

TEST

1 5 10 min

Before installation, record the model number
listed inside the fixture. attach receipt in case
of possible warranty issues.

model number:

Set the ON-TIME switch
on the sensor to TEST.

M e e t s t h e E N E R G Y S TA R

®

guidelines when D

ual

B

rite

®

func-

tion is off.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Dimmer cOntrOL; warning: turn power off at circuit

2 598-1183-03 DU AL BR ITE ® ON -TI ME TE ST 1 5 10 MIN OFF 3 6 DU SK TO DA WN DU AL BR ITE ® ON- TIM E TE ST 1 5 10 MIN OFF 3 6 D USK TO DA WN instaLL universaL mOunting Bracket For best performance, mount the fixture at least 8 feet (2.4 m) above the ground. Fixture Screw (Tightened Finger Tight) ...

Page 3 - recommended grounding method; Other wiring Options; contact a qualified

3 598-1183-03 Ground Screw white to white Black to Black recommended grounding method One Motion Sensing Light Two Motion Sensing Lights (Working Independently) Other wiring Options This fixture can be wired to control another standard or motion sensing light fixture(s). See the following wiring dia...

Page 4 - testing; turn on the circuit breaker and light switch.; Note: Sensor has a 1; if the dual controlled wiring is not done; instaLL Fixture Base tO; DualBrite; SENSITIVITY; Maximum Range

4 598-1183-03 testing 1. turn on the circuit breaker and light switch. Note: Sensor has a 1 1 / 2 minute warm up period before it will detect motion. When first turned on wait 1 1 / 2 minutes. 2. Set the ON-TIME switch to the TEST position and the D ual B rite ® switch to the OFF position. 3. Walk t...

Other Heath Zenith Models