Heath Zenith SH-5407 - Manual

Heath Zenith SH-5407

Heath Zenith SH-5407 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – INSTALLATION; TEST AND ADJUSTMENT
  • Page 3 – Bottom of Sensor; SPECIFICATIONS
  • Page 4 – TROUBLESHOOTING GUIDE; TECHNICAL SERVICE; before returning product to store.; No Service Parts Available for this Product
  • Page 5 – • LED indica que se ha detectado movimiento; FUNCIONAMIENTO; Mueva el interruptor de; Resumen de las modalidades del; Cuando lo prenda por primera vez espere unos 1; PRUEBA; Tiempo de; Prueba; segundos; Manual
  • Page 7 – Parte de abajo del detector; ESPECIFICACIONES
  • Page 8 – GUIA DE INVESTIGACION DE AVERIAS; SERVICIO TÉCNICO; de devolver el producto a la tienda.; No hay piezas de servicio disponibles para este producto.
Loading the manual

Replacement
Motion Sensor

Requirements

• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must

be wired through a switch.

Some codes require installation by a qualifi ed
electrician.

© 2007 HeathCo LLC

598-1155-01

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight

hours.

• LED indicates motion was sensed (day or

night).

Model SH-5407

OPERATION

Move ON-TIME Switch

to 1, 5, or 10 minutes

Mode Switching Summary

Flip switch off for

one second then

back on*

* resets to Auto Mode at dawn.

TEST

AUTO

MANUAL MODE

ON-TIME

ON-TIME

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time (1

1

/

2

min.) the control will be in the

AUTO mode.

10 5 1

TEST

10 5 1

TEST

MANUAL MODE

AUTO

TEST

... back on.

1 Second OFF

then

...

Manual mode only works at night
because daylight returns the sen-
sor to AUTO.

Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.

Manual mode works only with
the ON-TIME switch in the 1, 5,
or 10 position.

Note:

When fi rst turned on wait about 1

1

/

2

minutes

for the circuitry to calibrate.

Put the ON-TIME switch in the 1,
5, or 10 minute position.

Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Normal

1, 5, 10 min.

x

Manual

Until Dawn*

x

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; TEST AND ADJUSTMENT

-2- 598-1155-01 ❒ Swing the sensor head towards the clamp screw. For eave mount only: Controls INSTALLATION ❒ Remove the existing light fi xture, if present. These instructions show the sensor wired to fl ood-lamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the ...

Page 3 - Bottom of Sensor; SPECIFICATIONS

-3- 598-1155-01 Motion Least Sensitive Most Sensitive Sensor Motion The sensor is less sensitive to motion directly to-wards it, most sensitive to motion across its fi eld of view. Maximum Range Maximum Coverage Angle 8 ft. (2.4m) 70 ft. (21m) RANGE 10 5 1 TEST ON-TIME Bottom of Sensor Avoid aiming ...

Page 4 - TROUBLESHOOTING GUIDE; TECHNICAL SERVICE; before returning product to store.; No Service Parts Available for this Product

-4- 598-1155-01 TROUBLESHOOTING GUIDE SYMPTOM L i g h t s w i l l n o t come on. Lights come on in daylight. Lights come on for no apparent reason. POSSIBLE CAUSE 1. Light switch is turned off.2. Light is loose or burned out.3. Fuse is blown or circuit breaker is turned off. 4. Daylight turn-off is ...

Other Heath Zenith Models