Heath Zenith 121AC - Manual
Heath Zenith 121AC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – REPLACEMENT INSTALLATION WIRING; section for more information.; HELPFUL HINTS; requires a minimum 16 Volt, 10 Watt transformer.
- Page 3 – No Service Parts Available for this Product; TECHNICAL SERVICE
- Page 4 – Las ilustraciones pueden variar de la unidad de campana real.; CABLEADO PARA UNA NUEVA INSTALACION; Instalar el transformador de 16 voltios,; SUGERENCIAS DE MONTAJE; Campana mecánica con cableado blindado; Figura 1
- Page 6 – ANÁLISIS DE AVERÍAS; No hay piezas de servicio disponibles para este producto; SERVICIO TÉCNICO
- Page 7 – Le carillon peut être différent de l’appareil illustré.; CÂBLAGE POUR UNE NOUVELLE INSTALLATION; dans l’emballage, marquez « T » sur un fil, puis « C » sur l’autre.; SUGGESTIONS D’INSTALLATION; Carillons mécaniques câblés; Figure 1
- Page 8 – REMPLACEMENT DU CÂBLAGE
- Page 9 – CONSEILS PRATIQUES; Mais ce carillon exige un transformateur 16 V, 10 W minimum.; DÉPANNAGE; Aucune pièce de rechange n’est disponible pour ce produit; SERVICE TECHNIQUE
- Page 10 – GARANTIE LIMITÉE DE 1 AN
P.O. Box 90004
Bowling Green, KY 42102-9004
Illustrations may vary from actual chime unit.
© 2003 DESA Specialty Products™
598-1112-01
NEW INSTALLATION WIRING
WARNING: Turn power off at fuse or
circuit breaker before installing
transformer. Follow all national and
local codes.
1. Mount Transformer: Transformers
should be mounted on or near a
junction box. They can also be
mounted to the electrical service
panels. Junction boxes in utility
rooms, crawl spaces, or basements
are preferred. Avoid attic locations.
2. Install 16 Volt, 10 Watt transformer
according to the instructions supplied
with transformer.
Note: For multiple
mechanical chimes, use a 16 Volt,
15 Watt transformer. Failure to use
a transformer with adequate power
will result in loss of sound or may re-
sult in the system being inoperative.
3. Run two No. 20 AWG or better bell
wires (Heath
®
/Zenith No. 196C or No.
199C accessory wire) to the chime
location. Strip away 1/2" of insulation
from end of wires. Connect each wire
to transformer (see Figure 1).
4. Label Transformer Wires: Using masking tape or wire tags provided on packaging, label one
wire “T” and the other “C”.
FR
ONT
TRANS
REAR
FR
ONT
REAR
TRANS
DO NO
T OIL
Figure 1
Front Push Button
Rear Push Button
(If Applicable)
Optional Second Mechanical Chime
Transformer
Cover Pin
MOUNTING SUGGESTIONS
• Power must be supplied from a 16 Volt, 10 Watt transformer or 16 Volt, 15 Watt transformer
(Heath
®
/Zenith models 122C, 121AC, or 125C).
• Mount door chime in a central location so it can be heard throughout the home.
• See actual unit for orientation of base.
• Use wall anchors if not mounting directly to wall stud.
• Use mounting holes located on both sides of base.
• Route wires through wire entrance holes (see Figure 1).
Wire Nut
Mounting
Slot
Wire Entrance
Holes
Mounting
Hole
Base Style “A”
Base Style “B”
Hardwired Mechanical Chimes
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
-2- 598-1112-01 REPLACEMENT INSTALLATION WIRING For replacing an existing transformer, follow step 2 above.WARNING: Turn power off at fuse or circuit breaker before installing transformer.1. Verify existing chime/bell system works correctly. If no sound is heard, see Troubleshooting section for more...
-3- 598-1112-01 TROUBLESHOOTING Chime does not sound:• Check Chime: Disconnect wire from terminal marked “TRANS”. Have someone operate push button at front door while you momentarily touch the “TRANS” wire to terminal marked “FRONT”.You will see a small spark if push button, wiring, and transformer ...
-4- 598-1112-01 P.O. Box 90004 Bowling Green, KY 42102-9004 Las ilustraciones pueden variar de la unidad de campana real. CABLEADO PARA UNA NUEVA INSTALACION A DV E RT E N C I A : D e s c o n e c t a r l aenergía al fusible o al interruptor dec i r c u i t o a n t e s d e i n s t a l a r e ltransfor...