Page 2 - II; Guarantee Card; Name of Purchaser
Microlife BP W100 1 4 2 3 6 5 I AT 7 8 9 AO AK AN AL AM II Guarantee Card BP W100 Name of Purchaser . . . . І . . Serial Number Date of Purchase Specialist Dealer i
Page 3 - Display
1 BP W100 EN Display Read the instructions carefully before using this device. Dear Customer,Your new Microlife blood pressure monitor is a reliable medical instrument for taking measurements on the wrist. It is simple to use, accurate and comes highly recommended for blood pressure moni-toring in y...
Page 5 - ously high
3 BP W100 EN measurement taken on the upper arm. We therefore advise you to compare these values with those produced by the upper arm measurement and discuss them with your doctor. Enter your readings in the enclosed blood pressure diary . This will give your doctor a quick overview. There are m...
Page 6 - Using the Instrument for the First Time; Activating the fitted batteries; Taking a Blood Pressure Measurement using this; Checklist for taking a reliable measurement; AN
4 The higher value is the one that determines the evaluation. Example: a readout value between 150/85 or 120/98 mmHg indicates «blood pressure too high». 2. Using the Instrument for the First Time Activating the fitted batteries Pull out the protective strip from the battery compartment 3 . Setting ...
Page 7 - AM
5 BP W100 EN You can stop the measurement at any time by pressing the ON/OFF button (e.g. if you feel uneasy or an unpleasant pres-sure sensation). 4. Appearance of the Heart Arrhythmia Indicator for early Detection This symbol AM indicates that certain pulse irregularities were detected during th...
Page 8 - How not to store a reading; AL; Setting the Alarm Function; AK; Battery Indicator and Battery change; Low battery; Flat battery – replacement; AO
6 How not to store a reading Press the ON/OFF button 1 while the reading is being displayed. Keep the button pressed until « M » AL is flashing and then release it. Confirm by pressing the M-button again. 6. Setting the Alarm Function This instrument allows you to set 2 alarm times at which an alarm...
Page 11 - Technical Specifications; Operating temperature:
9 BP W100 EN Accuracy test We recommend this instrument is tested for accuracy every 2 years or after mechanical impact (e.g. being dropped). Please contact Microlife-Service to arrange the test (see foreword). Disposal Batteries and electronic instruments must be disposed of in accordance with the ...
Page 13 - BF
11 BP W100 RU 1. • ? 2. • • 3. 4. 5. • • • • 6. 7. • • • Э • 8. 9. , , • • • • • 10.11. BF 1. - , . , - ( ) ( ) . , ( ).
Page 17 - CL
15 BP W100 RU 5. , . M 5 . « M » AL , « M 17 ». Э , 17 . . M . M . , 200 - , . , . , , M ( ) « CL » . M , « CL ». . К y / Ы 1 . , « M » AL , - . M. 6. 2 , . Э , , . , . . , . ( , ), - . , .
Page 19 - oc a
17 BP W100 RU 3. , , , « 2.». , ( ) – . Э 2 1,5 AAA. . oc a , - . , . , «NiMH». , ( ). , ( ). , ! ! , ! 8. , , « ERR 3 ». « ERR 1 » . .* « ERR 2 » - , , , . , .
Page 20 - LO
18 * П , , - . , , , , « 1.». 9. , , , . , . , - . , « - »! : - - - - - - , . « ERR 3 » . , . , . . . « ERR 5 » ( ) , - . .* « HI » ( 300 . .) ( 200 ). 5 .* « LO » ( 40 ). .*
Page 22 - AAA
20 11. Э 93/42/EEC. . : 10 40 °C 15 - 95 % : -20 +55 °C 15 - 95 % : 130 . ( ) : 80 x 70 x 70 : , : I - , V : 20 - 280 . . – 40 - 200 – : 0–299 . . : 1 . . : ± 3 . . : ±5 % : 2 x 1,5 ; AAA К : , - 2 ., - , - , - : EN 1060-1 /-3 /-4; IEC 60601-1;IEC 60601-1-2 (EMC)