Page 2 - QuickSpecs; Overview
Standard Slot 1: low-profile x16 PCI-Express 2.0Optional Slot 2: low-profile internal only x4 PCI-Express 2.0 Management : HP ProLiant Onboard Administrator Powered by Lights-Out 100 with optional LO100i Advanced Licenses forVirtual KVM and Virtual MediaThe HP ProLiant Easy Set-up CDs and ISO image ...
Page 4 - Processor; depend on the quantity and type of DIMMs installed.; Upgradeability; Upgradeable to two processors; Chipset; All processor models except for those identified below.; Memory Protection; Advanced memory protection; Standard Features
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. Processor One of the followingdepending on Model Quad-Core Processors Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W,...
Page 6 - In order to connect a USB device internally, the internal USB; Graphics; Can support two SL160z server trays in the 2U chassis.
Storage Optical Drives DVD-ROM / DVD RW drives via USB only Diskette Drives Via USB only Drive Bays None ship standard Up to 2 Non-hot plug SATA 3.5" drives Maximum InternalStorage Non-Hot Plug SATA 2.0TB 2 x 1TB Interfaces Parallel None Network RJ-45 2 10/100/1000 NIC ports (plus 1 optional ded...
Page 8 - Security; For more information about TPM, including a white paper, go to:; Server Power Cords
Industry StandardCompliance ACPI V2.0 Compliant PCI 2.2 Compliant PXE Support WOL Support Microsoft® Logo certifications IPMI 2.0 DCMI 1.0 SMASH CLP compliant Security Power-on password Setup password Diskette boot control Secure Sockets Layer (SSL) Secure Shell (SSH) Security - TrustedPlatform Modu...
Page 9 - Power Supply; or; Common Slot ProLiant; for; System Fans; system fans ship standard in z6000 chassis
Power Supply HP has a new design for ProLiant power- the new Common Slot Power Supply bay. This designprovides the customer with commonality in power supplies across multiple platforms to save onthe cost of spares and allows HP to offer multiple power solutions to fit the customers' needs.Many HP Pr...
Page 10 - adequate airflow and to prevent damage to the equipment:; Rack Support; 0U bulk rail kit - Used to fit in HP 10000 series racks
Rack AirflowRequirements Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased coolingefficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow formaximum cooling, allowing these racks to be fully loaded with server...
Page 12 - PCI-Express Generation 2 adapters; Gigabit Ethernet; Use embedded ports; HPC Interconnects
NOTE: High Performance Computing (HPC) interconnect technologies are available for the SL160z G6 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configureto order clusters. Solutions can be defined with a lot of flexi...
Page 13 - HP ProLiant SL160z G6 Server; Rail Kits; HP 460W CS HE Power Supply Kit; Processors; Configuration Information - Factory Integrated Models
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local salesrepresentative for additional information. NOTE: HP does not allow factory integ...
Page 14 - Memory; Maximum 12 DIMMs supported per node.
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800),FIO NOTE: If 2 processors are desired, select one 539198-L21 and one 539198- B21. 539198-L21 Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066,HT, Turbo 1/1/2/2), FIO NOTE: If 2 processors are desired, select one...
Page 15 - Hard Drive; The hard drives use a quick release carrier.; Step 3: Choose Additional Options for Factory Integration
Hard Drive NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the Controller. Refer to the Controller technical specifications fordetails. NOTE: The hard drives use a quick release carrier. SATA Entry (ETY) Drives - with quick-release (QR) carrier HP 160GB 3G SATA...
Page 16 - DDR3 speed is the maximum memory speed of the processor. Actual; Core Options
NOTE: Some options may not be factory integrated. Please contact your local sales representative for additional information. HP ProLiant SL160z G6Unique Options HP Dedicated MGT Port Kit 516006-B21 HP I/O Riser x16 SL160/170 G6 KIT 574806-B21 HP Internal USB Cable G6 Kit 536769-B21 HP ProLiant z6000...
Page 17 - Hard Drives; Communications
Memory Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21 HP 8GB 2Rx4 PC3-10600R-9 Kit 500662-B21 HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21 Unbuffered with ECC DIMMs (UDIMMs) NOTE: Maximum 12 DIMMs supporte...
Page 18 - Redundant Options; In ProLiant Servers that have more than one power slot (bay), only
Redundant Options CAUTION: In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies areinserted you will get errors and operation will fail. HP 460W CS HE Power Supply Kit 503296-B21 HP 750W CS HE Power Supply Kit 5123...
Page 19 - Additional Options
Remote Management HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7Technical Support and Updates 530521-B21 NOTE: For additional information, please see the Lights-Out 100i QuickSpecs at: www.hp.com/go/lo100 . HP Insight ControlEnvironment Suite(ICE) NOTE: Electronic licens...
Page 20 - Rail Options; 0U rail kit used for HP racks ONLY - allows addition of five z6000; The following is a list of all Fibre Channel Host Bus Adapters for; StorageWorks SCSI HBA; Recommended HBA for MSL SCSI Tape Library connect.
Rail Options HP ProLiant z6000 G6 2U rail kit NOTE: 2U rail kit used for HP or 3rd part racks - allows addition of one z6000 chassis at a time. 570226-B21 HP ProLiant z6000 G6 10U Bulk rail kit NOTE: 10U rail kit used for HP racks ONLY - allows addition of five z6000 chassis at a time. 570227-B21 HP...
Page 23 - Charts do not represent all possible memory configurations.; DDR3 memory population guidelines
HP ProLiant SL160z G6 (all models) NOTE: Memory configurations listed do not apply to "Factory Integrated Models". NOTE: Charts do not represent all possible memory configurations. DDR3 memory population guidelines For detailed memory configuration rules and guidelines, please use the Online...
Page 24 - Standard memory configuration (1 CPU model); population order; Standard memory plus optional memory (1 CPU model)
If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC) in each of theother channels, you run at 1066MHzIf you install 3DPC in one channel (if applicable) and 1DPC in all other channels, you run at 800MHz95 Watt CPU's are required for 1333MHz DIMM speeds. All o...
Page 25 - UDIMM maximum configuration (1 CPU model)
CPU1 CPU2 slot # population order slot # population order Chnl 1 1 G; empty 1 G; empty Chnl 1 2 D; 2GB DIMM 2 D; empty 3 A; 2GB DIMM 3 A; empty Chnl 2 4 H; empty 4 H; empty Chnl 2 5 E; 2GB DIMM 5 E; empty 6 B; 2GB DIMM 6 B; empty Chnl 3 7 I; empty 7 I; empty Chnl 3 8 F; 2GB DIMM 8 F; empty 9 C; 2GB ...
Page 26 - UDIMM maximum configuration (2 CPU model)
Standard memory replaced with optional memory (2 CPU model)RDIMM maximum configuration 144GB, consisting of eighteen (18) 8GB PC3-8500 RDIMMs CPU1 CPU2 slot # population order slot # population order Chnl 1 1 G; 8GB DIMM 1 G; 8GB DIMM Chnl 1 2 D; 8GB DIMM 2 D; 8GB DIMM 3 A; 8GB DIMM 3 A; 8GB DIMM Ch...
Page 28 - Drive Support; the HBA or Controller technical specifications for details.; Storage
1-2 Non-hot plug SATA hard drive bays - Using quickrelease carrier Drive Support Hard Drives NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. SATA Entry (ETY) Drives - wi...
Page 29 - Power Specifications
HP 460W Power SupplyPart Number - AC 460W PSU 503296-B21 Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) 100 120 208 200 220 230 240 Maximum Rated OutputWattage 460 460 460 460 460 460 460 Nominal Input Current (A rms) 5.5 4.5 2.6 2.5 2.4 2.3 2...
Page 30 - Power Factor
HP 1200W Power SupplyPart Number - AC 500172-B21 Operational Input VoltageRange (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) 100 120 208 200 220 230 240 Maximum Rated OutputWattage 800 900 1200 1200 1200 1200 1200 Nominal Input Current (A rms) 9.7 9.0 7.0 6.8 6...
Page 31 - Technical Specifications
System Unit Dimensions (H x W x D) (with bezel) 3.46 x 17.64 x 28.1 in (8.79 x 44.80 x 71.37 cm) Weight (approximate) Maximum(all hard drives, powersupplies, and processorsinstalled) 53.7 lb (24.35 kg) Input Requirements (per power supply) Rated Line Voltage 90 to 132 VAC180 to 264 VAC Rated Input C...
Page 32 - FCC Rating
declared average bystander position A-Weighted sound pressure levels(LpAm) when the product is operating in a 23°C ambient environment.Noise emissions were measured in accordance with ISO 7779 (ECMA74) and declared in accordance with ISO 9296 (ECMA 109). Idle L WAd 6.86 L pAm 52.36dBA Operating L WA...