Quadra-Fire 7051-158B - Manual

Quadra-Fire 7051-158B

Quadra-Fire 7051-158B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
Page: / 58

Table of Contents:

  • Page 2 – Page 2; EDGE 60 Pellet Fireplace; Hearth & Home Technologies welcomes you to our tradition of; Manufacture Date; LOCATION OF SERIAL NUMBER LABEL: Right Inside Edge of Outer Can; Figure 2 - Serial Number Label; CAUTION; EDGE 60 PELLET
  • Page 3 – Page 3; User’s Guide; Safety Alert Key:
  • Page 4 – Page 4
  • Page 5 – Page 5
  • Page 6 – Page 6; The structural integrity of the mobile home; B. Mobile Home Approved; This installation must conform with local codes.; D. Electrical Rating; Hearth & Home Technologies, manufacturer; Listing and Code Approvals; required
  • Page 7 – Page 7; HOT SURF; Glass and other surfaces are hot during operation AND cool down.; Hot glass will cause burns.; WARNING; WARNING! Do not operate appliance before reading and
  • Page 8 – Page 8; Combustible Material; Clinkers; C. Fuel Material and Fuel Storage; biomass fuels; urn fuel that contains an additive; Do
  • Page 9 – Page 9; Changing to Different Fuel Type; D. General Operating Information; Thermostat Wall Control - Automatic Setting; F. Before Your First Fire; The tip of thermocouple must be in contact with the; Tested and approved for wood pellets, shelled
  • Page 10 – RAISED PLATFORM INSTALLATIONS; H. Starting Your First Fire; • Select the appropriate fuel on the FUEL SELECTION screen; Comfort Level Selection
  • Page 12 – Battery; Figure
  • Page 13 – Keep combustible materials,; MAINT BURN; Wall Control Display
  • Page 14 – • Proper Shutdown Procedure must be followed.; A. Proper Shutdown Procedure; • Set wall control to OFF on AUTOMATIC / MANUAL SET-; Before Servicing Your Appliance; Manual; Maintaining & Servicing Your Appliance; B. Quick Reference Maintenance Chart; warranty; Cleaning or Inspection; Frequency
  • Page 15 – D. Accessing Components for Maintenance; C. High Ash Fuel Content Maintenance; • High ash fuels or lack of maintenance can cause fi repot to
  • Page 16 – Figure C on page 57; See Disposal of Ashes.; E. General Maintenance and Cleaning; Handle glass doors with care.
  • Page 17 – NOTE: There are heavy duty vacuum cleaners specifi cally; * Can be purchased at your local hardware store.; It is necessary to remove the baffl e to gain access to the; se the crevice tool to fi nish cleaning the heat exchanger; There are several ways this can done.
  • Page 18 – Ash Removal from Firebox; Clinker; however you do not need to disconnect the wires.; Vacuum out the exhaust area.
  • Page 20 – Prior to each burn season and after pro-
  • Page 21 – ISSUES; Noise is caused by metal expanding and contracting as it heats; Ash buildup on glass; Excessive build up of ash. The lower burn settings will produce; Fire has tall fl ames with black tails and is lazy; The fl ame height adjustment needs to be reduced or the fi repot; Troubleshooting for Homeowner; A. Frequently Asked Questions
  • Page 22 – Possible Cause
  • Page 23 – Getting Started; Installer’s Guide; WARNING! Risk of Fire; Appliance Location; Contact local building or fire officials about
  • Page 24 – Description; Hearth extension fl oor protection; B. Thermostat Wall Control Location; When located close to the appliance, it may require a; C. Tools And Supplies Needed; Damaged parts could impair safe; installation to ensure maximum safety and benefi t.; DO NOT INSTALL IN SLEEPING ROOM
  • Page 25 – • The fi replace must be secured in place as outlined in; G. Items to Verify During Test Burn; Recommended Sequence; Outside Air Kit must be; before fi nishing
  • Page 26 – Framing Dimensions & Clearances; A. Recommended Locations; Location
  • Page 27 – NOTE; D. Frame the Fireplace; • Framing across the top of fi replace must be above top standoffs.; inches; See Section 8 for outside air locations.
  • Page 28 – You may enclose the vent system in a chase.; See Figures; • Check local/regional building codes for compliance.
  • Page 29 – Behind the Mounting Frame; Mounting Frame
  • Page 30 – for; Opening Clearances for the Curved,; TOP VIEW; Curved Front
  • Page 31 – Opening Clearances; Studio Front
  • Page 32 – to Floor
  • Page 33 – ASTM E 136, Standard; J. Combustible Materials; • Do; Non-Combustible Sealant Material
  • Page 34 – Installation of Fireplace; A. Position the Fireplace; Place the fi replace on a continuous fl at surface or install on a; Flooring Material Under Appliance:; Fireplace MUST be level before securing in place.; lace; Testing for Defl ection & Removing Handles; ensure
  • Page 35 – There is a 5 screw terminal connection bar that is located; The center 3 screws are for the thermostat wall control; D. Connecting Wall Control To Fireplace; Shock Hazard; • A grounded metal outlet power supply box is; Grounding
  • Page 36 – Red Wire; F. Installing Flue Collar, Vertical or Horizontal; Vertical Installation; The thermostat wall control should be mounted; Locating Pins
  • Page 37 – Horizontal Installation
  • Page 38 – anges along the side.; Vent Information; A. Venting Termination Minimum Requirements; Termination must exhaust above air inlet elevation.; • It is recommended that at least 60 inches (1.52m) of vertical; public; An Outside Air Kit is required on all installations.; Outside Air Kit must be ordered separately.; Consult local building, fi re offi cials or authorities having; Do NOT Terminate Vent:; In any location which could create a nuisance or hazard.
  • Page 39 – Outside Air
  • Page 40 – Negative pressure can
  • Page 41 – Approved for all Listed pellet vent. As; System; : Secure to the appliance with; F. Equivalent Feet of Pipe
  • Page 42 – ALTITUDE IN THOUSANDS OF FEET; Example 1
  • Page 43 – “ventilated”; Figure 42.2 - Outside Combustion Air Placement; H. Outside Air Locations & Considerations
  • Page 44 – Collar; Install Outside Air Kit; Do not draw
  • Page 45 – Firestop; Clearance to combustibles are for 1 inch
  • Page 46 – Straight Out; ALL
  • Page 47 – Section 6; Spark Arrestor Cap; Mobile Home Installation; Never install in a sleeping room.
  • Page 48 – Due to the abrasive nature of; Place the left log as shown. There are 2 indentations in; PIECE LOG SET INSTALLATION; Logs are FRAGILE. Use extreme care when
  • Page 49 – Installing Front onto Mounting Frame; Installing Mounting Bracket on Fireplace; Allow the front to cool
  • Page 50 – A. Glass Replacement; Lay on a fl at surface face down.; Remove 4 screws; • Glass is 5mm thick high temperature heat-resistant ceramic; Replacement; Follow the proper shut down procedures as outlined on; Replacement Parts; Loosen all 6 nuts, but do NOT Remove
  • Page 51 – C. Convection Blower Replacement; The; Release the Latch
  • Page 52 – shooting guide shall be used by; Error Message; Troubleshooting For Installers
  • Page 53 – Outside; Front View; Reference Materials
  • Page 54 – Convection Blower
  • Page 55 – Control Board Schematic
  • Page 56 – Hopper
  • Page 57 – Date of Service; F. Service And Maintenance Log
  • Page 58 – Hearth & Home Technologies; Division of HNI INDUSTRIES; CONTACT INFORMATION; For the number of your nearest Quadra-Fire dealer; Location on appliance:; We recommend that you record the following pertinent; DO NOT DISCARD THIS MANUAL; NOTICE; • Important operating and; DO NOT
Loading the manual

R

www.quadrafi re.com

7051-158B

December 6, 2011

EDGE™ 60

ZERO CLEARANCE PELLET FIREPLACE

O - T L

Tested and

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Owner’s Manual

-

Installation and Operation

Model:

Tested and approved for wood pellets, shelled fi eld
corn, wheat and black oil sunfl ower seeds. Burning
of any other type of fuel voids your warranty.

WARNING

Installation and service of this appliance should
be performed by qualifi ed personnel. Hearth &
Home Technologies recommends NFI certifi ed
professionals, or technicians supervised by an
NFI certifi ed professional.

Hot glass will cause burns.

• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away

CAREFULLY SUPERVISE children in same room
as fi replace.

• Alert children and adults to hazards of high

temperatures.

High temperatures may ignite clothing or other
fl ammable materials.

• Keep clothing, furniture, draperies and other

fl ammable materials away.

HOT SURFACES!

Glass and other surfaces are
hot during operation AND
cool down.

CAUTION

WARNING

Please read this entire manual
before installation and use of this
pellet fuel-burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.

Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.

• Do not overfi re - If any external part starts to

glow, you are overfi ring. Reduce fl ame height
(feed rate). Overfi ring will void your warranty.

• Comply with all minimum clearances to com-

bustibles as specifi ed. Failure to comply may
cause house fi re.

DO NOT DISCARD THIS MANUAL

NOTICE

• Important operating and

main tenance instruc -
tions included.

Leave this manual with
party responsible for use
and operation.

Read, understand and
follow these instruc-
tions for safe installa-
tion and operation.

DO NOT

DISCARD

Natural

Curved

Tuscan

Studio

EDGE60

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Page 2; EDGE 60 Pellet Fireplace; Hearth & Home Technologies welcomes you to our tradition of; Manufacture Date; LOCATION OF SERIAL NUMBER LABEL: Right Inside Edge of Outer Can; Figure 2 - Serial Number Label; CAUTION; EDGE 60 PELLET

Page 2 7051-158B December 6, 2011 R EDGE 60 Pellet Fireplace Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and perfor-mance. This commitment begins with our research of the...

Page 3 - Page 3; User’s Guide; Safety Alert Key:

R December 6, 2011 7051-158B Page 3 EDGE 60 Pellet Fireplace Congratulations ............................................................... 2Sample of Safety/Serial Numer Label ............................. 2Safety Alert Key ............................................................... 3Limited W...

Page 4 - Page 4

Page 4 7051-158B December 6, 2011 R EDGE 60 Pellet Fireplace

Other Quadra-Fire Models

All Quadra-Fire Other