Page 2 - Installers Guide; DO NOT; Owners Guide; ALERTED; SAFETY AND WARNING INFORMATION
2 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 These units MUST use one of the vent systems described in the Installing the Fireplace section ofthe Installers Guide . NO OTHER vent systems or components MAY BE USED. This gas fireplace and vent assembly MUST be vented directly to the outsi...
Page 3 - TABLE OF CONTENTS
3 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 TABLE OF CONTENTS Safety and Warning Information ......................................................... 2 Service Parts Lists ................................................................................. 4 Section 1: Approvals and Code...
Page 4 - Part number list on following page.; Service Parts; Log Set Assembly
4 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Part number list on following page. 4 3 5 2 7 1 6 (NG, LP) Exploded Parts Diagram Service Parts QV32B-A Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ 8 Log Set Assembly 1 2 11 1 0 9 1 3 Î
Page 8 - Standing Pilot Ignition
8 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 (NG, LP) Exploded Parts Diagram Service Parts QV32B-A, QV36B-A Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ AVAILABLE TO SHIP IN 24 HOURS ITEM DESCRIPTION SERIAL # PART NUMBER 1 ON/OFF Rocker Switch 060-521A Y 2 Valve ...
Page 9 - The Village Collection fireplace models discussed in this; Certification; Underwriters Laboratories; High Altitude Installations
9 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 1 Approvals andCodes NOTE: THESE MODELS ARE UL LISTED TO UL307B,THE STANDARD FOR GAS-BURNING HEATING APPLI-ANCES FOR MANUFACTURED HOMES AND RECRE- ATIONAL VEHICLES. Installation Codes The fireplace installation must conform to local codes. Be...
Page 10 - The following requirements reference various
10 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 For all side wall horizontally vented gas fueled equipmentinstalled in every dwelling, building or structure used inwhole or in part for residential purposes, including thoseowned or operated by the Commonwealth and where theside wall exhaus...
Page 11 - Getting Started; Pre-install Preparation; Do not install any
11 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 2 Getting Started Introducing the Village CollectionGas Fireplaces The Village Collection direct vent gas fireplaces are designedto operate with all combustion air siphoned from outside ofthe building and all exhaust gases expelled to the ou...
Page 12 - Diagram of the QV36B-A
12 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 1. Diagram of the QV36B-A 30-11/16 (779mm) 1/2 (13mm) 15-5/16 (389mm) 16-3/8 (414mm) 8-3/4 (223mm) Ø 6-5/8 (168mm) 15-7/8 (402mm) 37-3/4 (960mm) ELECTRICAL ACCESS 3-9/16 (90mm) 6-7/8 (174mm) 40-15/16 (1040mm) 36-1/8 (917mm) 35-5/8 (90...
Page 13 - Diagram of the QV32B-A
13 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 2. Diagram of the QV32B-A TOP STANDOFFS GAS CONTROLS ELECTRICAL ACCESS GAS ACCESS RATING PLATE/ LABELS Ø6-5/8 (168mm) 25-11/16 (653mm) 12-7/8 (326mm) 1/2 (13mm) 16-3/8 (414mm) 8-13/16 (223mm) 15-7/8 (402mm) 3-1/3 (90mm) 32-9/16 (828mm...
Page 14 - Installing the Fireplace; Step 1. Locating the Fireplace; Vertical Sections; Constructing the Fireplace Chase
14 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 3 Installing the Fireplace Step 1. Locating the Fireplace The following diagram shows space and clearance require-ments for locating a fireplace within a room. Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Fr...
Page 15 - Step 2. Framing the Fireplace
15 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 5. Framing Dimensions Framing should beconstructed of 2 X 4lumber or heavier. WARNING: To ensure proper clearances the frontframing header must be installed on itsnarrow edge and to the front of the frame. The framing headers may rest...
Page 18 - Step 3. Installing the Vent System; vent collars. This pipe is tested and; Vent System Termination Kits; Identifying Vent Components; . Detailed installation instructions
18 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 ! Figure 8. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals These models have vent starting collars on both the topand the back of the unit. Depending upon the installation,decide which...
Page 19 - For vertical venting; STRAIGHT OUT HORIZONTAL VENTING; Figure 11. Straight Out Horizontal Venting; elbows for corner installations.; Flex Vent; CAP
19 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 STRAIGHT UP VERTICAL VENTING V (FT.) 45' MAX. Figure 10.Straight up Vertical Venting Use SL D-Series components only. NOTE: For vertical venting over 20 feet a restrictorplate is recommended forimproved flame appearance. STRAIGHT OUT HORIZON...
Page 20 - ELBOW NATURAL GAS
20 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m) Figure 12. Venting with One 90° Elbow Figure 13. Venting with One 90° ...
Page 21 - Figure 14. Venting with Two 90° Elbows; H + H
21 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 V H H + H 1 1' MIN. (305 mm) 2' MAX. (610 mm) 4' MAX. (1.22m) 2' MIN. (610 mm) 4' MAX. (1.22 m) 8' MAX. (2.4m) 3' MIN. (914 mm) 6' MAX. (1.86 m) 12' MAX. (3.6m) 4' MIN. (1.22 m) 8' MAX. (2.48 m) 16' MAX. (4.8m) V+H+H 1 = 40' MAX. (12.4 m) H ...
Page 22 - Figure 15. Venting with Two 90° Elbows; ELBOWS NATURAL GAS
22 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 15. Venting with Two 90° Elbows V H H 1 NOTE: There MUST be a 25% reductionin total H when using flex vent exceptwhen using the simple up and outinstallation (see Figure 9). Use SL D-Series components only. VENTING WITH TWO (2) 90 o E...
Page 23 - Figure 16. Venting with Two 90° Elbows
23 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 16. Venting with Two 90° Elbows Use SL D-Series components only. H V V 1 NOTE: There MUST be a 25%reduction in total H when usingflex vent except when usingthe simple up and out installa-tion (see Figure 9). VENTING WITH TWO (2) 90 o ...
Page 24 - Figure 17. Venting with Three 90° elbows; V H H + H
24 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 17. Venting with Three 90° elbows 1' MIN. (305 mm) 2' MAX. (610mm) 4' MAX. (1.22m) 2' MIN. (610 mm) 4' MAX. (1.22m) 8' MAX. (2.48m) 3' MIN. (914 mm) 6' MAX. (1.86m) 12' MAX. (3.72m) 4' MIN. (1.22 m) 8' MAX. (2.48m) 16' MAX. (4.8m) V 1...
Page 25 - Figure 18. Venting with three 90° elbows
25 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 18. Venting with three 90° elbows Use SL D-Series components only. H 1 H V 1 V NOTE: There MUST be a 25% reduction in total H whenusing flex vent except when using the simple up andout installation (see Figure 9). VENTING WITH THREE (...
Page 26 - Figure 19. Venting with three 90° elbows
26 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Use SL D-Series components only. Figure 19. Venting with three 90° elbows V 1 H 1 H V NOTE: There MUST be a 25% reduction intotal H when using flex vent except whenusing the simple up and out installation(see Figure 9). VENTING WITH THREE (3...
Page 27 - Figure 20. Venting with Four 90° elbows
27 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 20. Venting with Four 90° elbows VENTING WITH FOUR (4) 90° ELBOWS NATURAL AND PROPANE GAS V (MIN.) H (MAX.) 2' (609mm) 5' (1.52m) V 1 (MIN.) H 1 (MAX.) V 2 (MIN.) 5' (1.52m) 5' (1.52m) 4.5' (1.37m) V + V 1 + V 2 + H + H 1 MAX. = 40' (...
Page 28 - DVP Series Venting Only:; Go to Step 4 Install Firestops.
28 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 ! Figure 21. Insert screwdriver or similar object here to remove cap. CUT HERE Venting Out Rear Venting Out Top ! WARNING: THE REAR VENT COLLAR SEALCAP MUST REMAIN ATTACHED TO THE REAR VENT COLLARS IF THE VENT SYSTEM IS ATTACHEDTO THE TOP ST...
Page 31 - For Horizontal Terminations -; For DVP Venting Only:; Figure 29. Trapezoid Termination Cap
31 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 C. Vent Termination SL-Series Venting Only: For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent: • Rotate and interlock the ends as described at the begin- ning of the Installing Vent Com...
Page 32 - = AREA WHERE TERMINAL IS NOT PERMITTED; Figure 30. Vent Termination Minimum Clearances; public
32 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 30. Vent Termination Minimum Clearances A = 12" ....................... clearances above grade, veran- da, porch, deck or balcony B = 12" .............
Page 34 - Figure 33. Gas Control System; STANDING PILOT; Step 5. The Gas Control System; Standing Pilot Ignition System
34 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Step 4. Positioning, Leveling, and Securing the Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, such as sheet metal, as necess...
Page 35 - Figure 34. Gas Supply Line; Step 6. The Gas Supply Line; Pressure
35 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Figure 34. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between thepipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas ac...
Page 36 - Step 8. Wiring the Fireplace; This appliance
36 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensedelectrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB-SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-VENT ACCIDENTAL FIREPLACE OPERATION. For Standing Pilot ...
Page 37 - overlap onto the front face. The joints
37 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Step 9. Finishing Figure 37 shows the minimum vertical and correspondingmaximum horizontal dimensions of fireplace mantels or othercombustible projections above the top front edge of thefireplace. See Figures 3 and 4 for other fireplace clea...
Page 38 - Step 11. Before Lighting the Fireplace
38 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 WARNING: PLEASE REFER TO THE USER’SMANUAL FOR ALL CAUTIONS, SAFETY, ANDWARNING INFORMATION PERTAINING TO THELIGHTING AND OPERATION OF THE FIREPLACE. Placing the Ember Material Ember material is shipped with this gas fireplace. The baglabeled...
Page 39 - Step 12. Lighting the Appliance; STANDING PILOT IGNITION; When you light your fireplace, you may notice:; After the Installation
39 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Step 12. Lighting the Appliance STANDING PILOT IGNITION A. This appliance (standing pilot version) has a pilot that must be lighted by hand. When lighting thepilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the a...
Page 40 - Maintaining and Servicing Your Fireplace; Fireplace Maintenance; Placing Ember Material
40 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 4 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main-tenance will depend on use and the type of installation, youshould have a qualified service technician perform an ap...
Page 41 - Troubleshooting; Symptom
41 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Troubleshooting With proper installation, operation, and maintenance your gas fireplace willprovide years of trouble-free service. If you do experience a problem, thistroubleshooting guide will assist a qualified service person in the diagno...
Page 43 - Lifetime Warranty; LIMITED LIFETIME WARRANTY
43 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06 Lifetime Warranty LIMITED LIFETIME WARRANTY The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work asdesigned for the lifetime of the stove or Hearth & Home Technologies will repai...