Page 2 - and Welcome to the Quadra-Fire Family; CAUTION; SAMPLE OF SERIAL NUMBER / SAFETY LABEL; Model; S A; NOTE: Clearances may only be
Page 2 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) Hearth & Home Technologies welcomes you to our tradi- tion of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durabil- ity, and performance.This commitment begins with our research o...
Page 3 - Page 3; Section 4: Installation Consideration; A. Quick Reference Maintenance Guide . 27; Section 11: Reference Material; TABLE OF CONTENTS; Safety Alert Key:
May 5, 2011 7039-131H Page 3 2100 Millennium Wood Stove (ACC) R Section 1: Listing and Code Approvals A. Appliance Certifications ...................... 4 B. Mobile Home Approved ...................... 4 C. Glass Specifications ............................ 4 D. BTU & Efficiency Specifications .....
Page 4 - Listing and Code Approvals; A. Appliance Certification; EPA Certificate Number; WARNING; B. Mobile Home Approved
Page 4 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) 1 Listing and Code Approvals The Quadra-Fire 2100 Millennium Wood Stove (ACC) meets the U.S. Environmental Protection Agency’s 1990 particulate emission standards. A. Appliance Certification C. Glass Specifications D. BTU & Efficien...
Page 5 - Getting Started; ations; Any such action that may cause a fire hazard.
May 5, 2011 7039-131H Page 5 2100 Millennium Wood Stove (ACC) R 2 Getting Started A . Design, Installation & Location Consider ations Consideration must be given to: • Safety • Convenience • Traffic flow • Chimney and chimney connector required It is a good idea to plan your installation on pape...
Page 6 - C. Negative Pressure; Negative pressure; • Negative pressure can cause spillage of com-
Page 6 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended: Outside Air Intake on windward side NOT recommended: Outside Air Intak...
Page 7 - D. Flue Draft Considerations; on page 6; F. Tools And Supplies Needed
May 5, 2011 7039-131H Page 7 2100 Millennium Wood Stove (ACC) R Exterior conditions such as roof line, surrounding trees, prevailing winds and nearby hills can influence stove performance. Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions ...
Page 8 - Figure 8.1 Masonry Chimney; H. Typical Stove Systems
Page 8 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) Floor Protector Chimney Connector Insulated " T " Flashing Listed Termination Cap Trim Collar on Inside Wall Listed Chimney Storm Collar Wall Support Roof Brace (if required) Thimble Floor Protector Thimble, 12" (305mm) Of B...
Page 9 - Page 9; Dimensions and Clearances; Outside Air; A. Appliance Dimensions; Figure 9.1 Front View; NOTE: Flue Collar size is 6 inch; CL
May 5, 2011 7039-131H Page 9 2100 Millennium Wood Stove (ACC) R 3 Dimensions and Clearances 26-7/16 in. (671mm) 24-5/16 in. (618mm) 6-11/16 in. (170mm) 16 in. (406mm) 11-1/2 in. (292mm) 20-3/4 in. (527mm) C L CL 4-1/2 in (108mm) Outside Air Connection A. Appliance Dimensions Figure 9.1 Front View Fi...
Page 10 - NOTE: Clearances may only be reduced by means; • Comply with all minimum clearances to; In order to replace the tube channel assembly a clearance
Page 10 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) B. Clearances to Combustibles (UL and ULC) BACKWALL / SIDEWALL A B C D E F E F CORNER INSTALLATION STOVE TO CEILING CLEARANCE C D ALCOVE TOP VIEW G A B ALCOVE SIDE VIEW NOTE: Clearances may only be reduced by means approved by the regu...
Page 11 - Hearth Protection Requirements; Non-combustible floor protections must; Installation; • Hearth pads must be installed exactly as
May 5, 2011 7039-131H Page 11 2100 Millennium Wood Stove (ACC) R A. Hearth Protection Requirements FLOOR PROTECTION: Floor protector must be non-com- bustible material, extending beneath heater and to the front, sides and rear as indicated. The floor must be non-com- bustible or otherwise adequately...
Page 12 - B. Outside Air Kit Installation; Items Needed for Installation (not supplied); Figure 12.2 - Floor Installation Alternative; Cover; Floor Installation Alternative:
Page 12 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) B. Outside Air Kit Installation 1. Remove all materials from packing box.2. Using a #2 Phillips screw driver attach the flex adapter to the stove using 4 screws. Figure 12.1. 3. For floor installations, remove circular “knock-out” in t...
Page 13 - Shock Risk
May 5, 2011 7039-131H Page 13 2100 Millennium Wood Stove (ACC) R C. Blower (Optional) 1. Remove the 3 bolts (1/4”-20 Phillips head) on the outer skin at the bottom rear of appliance. 2. Align holes in mounting flange of blower with bolt holes in appliance. Blower should be positioned at bottom of re...
Page 14 - Chimney Requirements; Figure 14.1 Prefabricated Exterior Chimney; A. Venting Components; Thimble
Page 14 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) NOTE: I n Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100 o F) CLASS “A” or conforming to CAN/ULC-S629M, STANDARD FOR 650 o C FACTORY-BUILT CHIMNEYS. 5 Chimney Requirements Floor Protector Chimne...
Page 15 - Site constructed for masonry chimney installation:; Components; Do NOT pack insulation or other combustibles between
May 5, 2011 7039-131H Page 15 2100 Millennium Wood Stove (ACC) R Thimble Site constructed for masonry chimney installation: Components • A minimum length of 12 inches [305mm] (longer for thicker walls) of solid insulated factory-built chimney length constructed to UL 103 Type HT 6 inch (152mm) insid...
Page 16 - Chimney Height / Rise and Run; C. Installing Chimney Components; Chimney Connector; Fire Risk; Solid Pack Chimney with Metal Supports as a
Page 16 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) Chimney Height / Rise and Run This product was designed for and tested on a 6 inch (152mm) chimney, 14 to 16 feet (420-480cm) high, (includes stove height) measured from the base of the appliance. The further your stack height or diame...
Page 17 - D. Chimney Termination Requirements; and; • Chimney height may need adjustment if smoking or; Pitched Roof; Flat Roof
May 5, 2011 7039-131H Page 17 2100 Millennium Wood Stove (ACC) R D. Chimney Termination Requirements Follow manufacturer’s instructions for clearance, securing flashing and terminating the chimney. • Must have an approved and listed cap • Must not be located where it will become plugged by snow or o...
Page 18 - Mobile Home Installation; You must use a Quadra-Fire Outside Air Kit Part; THE STRUCTURAL INTEGRITY OF THE MOBILE HOME
Page 18 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) 6 Mobile Home Installation 10. Burn wood only. Other types of fuels may generate poisonous gases (e.g., carbon monoxide). 11. If unit burns poorly while an exhaust blower is on in home, (i.e., range hood), increase combustion air. 12. ...
Page 19 - required; • Do NOT overtighten lock nut.; required from bend in door; • Maintain clearance between bend of
May 5, 2011 7039-131H Page 19 2100 Millennium Wood Stove (ACC) R NOTE: When the speed control is turned clockwise, it will click on to high speed. Continue to turn the speed control clockwise to decrease the speed. At full clockwise, the blower should blow gently, but should not stop. 1. With the ap...
Page 20 - Operating Instructions; Kindling or First Stage; • Overload with wood
Page 20 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) 8 Operating Instructions B. Wood Selection & Storage Burn only dry seasoned wood. Store wood under cover, out of the rain and snow. Dry and well-seasoned wood will not only minimize the chance of creosote formation, but will give y...
Page 22 - F. Burn Rates and Operating Efficiency; For maximum operating efficiency; These are approximate settings, and will vary with; When set on High Burn Rate and over-riding; REAR AIR; Closed; Shown with Side
Page 22 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) F. Burn Rates and Operating Efficiency For maximum operating efficiency 1. This appliance has a timer system (ACC) that operates the stove at its maximum efficiency removing any guess work for the homeowner. Follow the instructions bel...
Page 23 - Figure; ing
May 5, 2011 7039-131H Page 23 2100 Millennium Wood Stove (ACC) R G. Building A Fire Before lighting your first fire in the stove: 1. Confirm the baffle is correctly positioned. It should be even with the front tube and resting on all tubes. Figure 23.1. 2. Remove all labels from glass.There are many...
Page 24 - wood burning appliance with the baffle in the; Ceramic Blanket
Page 24 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) CORRECT POSITION INCORRECT POSITIONS Firebox damage due to improper baffle place-ment is not covered by warranty. Operate the wood burning appliance with the baffle in the correct position only. Not doing so could result in: • Reduced ...
Page 25 - I. Blower Operating Instructions; Keep combustible materials, gasoline
May 5, 2011 7039-131H Page 25 2100 Millennium Wood Stove (ACC) R J. Opacity (Smoke) This is the measure of how cleanly your appliance is burn- ing. Opacity is measured in percent; 100% opacity is when an object is totally obscured by the smoke column from a chimney, and 0% opacity means that no smok...
Page 26 - K. Frequently Asked Questions; ISSUES; Odor from appliance; Odors and vapors released during initial operation.
Page 26 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) K. Frequently Asked Questions ISSUES SOLUTIONS Odor from appliance When first operated, this appliance may release an odor for the first several hours. This is caused by the curing of the paint and the burning off of any oils remaining...
Page 27 - A. Quick Reference Maintenance Guide; Start the first inspection of your unit af-; BAFFLE & BLANKET PLACEMENT; Step Top Models Only; Maintenance is required for safe oper-; Maintaining & Servicing Your Appliance
May 5, 2011 7039-131H Page 27 2100 Millennium Wood Stove (ACC) R A. Quick Reference Maintenance Guide 2 2 Baffle and blanket placement is critical to heat out- put, efficiency and overall life of the unit. Make sure the baffle is pushed all of the way to the back of the firebox and the blanket is la...
Page 28 - B. General Maintenance; Formation and Need For Removal; Certified Chimney Sweep; Disposal of Ashes; • Ignited creosote is extremely HOT.
Page 28 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) B. General Maintenance Inspection: Inspect the system at the appliance connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top as well as from the...
Page 29 - C. Glass Replacement
May 5, 2011 7039-131H Page 29 2100 Millennium Wood Stove (ACC) R C. Glass Replacement 1. Ensure that the fire is out and the appliance is cool to the touch. 2. Protect a table or counter top with padding or towels. Protect your hands and wear gloves to prevent injury. 3. Remove the door with the bro...
Page 30 - D. Firebrick Replacement; Use Part 832-0550 when ordering individual brick. Provide brick; Brick Size
Page 30 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) Replace the firebrick if they become crumbly and/or if there is a 1/4 inch (6.35mm) gap between the bricks. Inspect the firebrick after each ash removal. The firebox is lined with high quality firebrick, which has exceptional insulatin...
Page 31 - Correct Blanket & Baffle Position on page 24.; F. Snap Disc Replacement
May 5, 2011 7039-131H Page 31 2100 Millennium Wood Stove (ACC) R E. Baffle Removal 1. Remove all ash from the firebox, and extinguish all hot embers before disposal into a metal container. 2. The baffle board has 2 pieces. With the ceramic blanket still in place, slide one baffle piece over the top ...
Page 32 - G. Tube Channel Assembly Replacement; Removing Tube Channel Assembly
Page 32 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) G. Tube Channel Assembly Replacement Removing Tube Channel Assembly 1. Remove the right side shield by removing 2 screws in the back using a Phillips head screw driver. 2. Remove 4 screws from channel access cover and remove cover. 3. ...
Page 33 - Troubleshooting; the diagnosis of a problem and the corrective action to be taken.; Start Fire Problems
May 5, 2011 7039-131H Page 33 2100 Millennium Wood Stove (ACC) R 10 Troubleshooting With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service. If you do experience a prob- lem, this troubleshooting guide will assist a qualified service person in t...
Page 35 - Service Parts; in this manual may be ordered from an authorized dealer.; Stocked; ITEM; Additional service part numbers appear on following page.
May 5, 2011 7039-131H Page 35 2100 Millennium Wood Stove (ACC) R Service Parts 04/11 R 21M-ACC Beginning Manufacturing Date: July 2007 Ending Manufacturing Date: Active 4.4 1-3/8” 1-3/4” 6-1/4” 8-1/2” 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.2 4.2 4.2 4.4 4.3 4.3 4.5 8-1/2” 3” 7” 4.5 #4 Brick Assembly ...
Page 36 - fl; Side view
Page 36 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) Service Parts 04/11 R IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorize...
Page 38 - C. Service And Maintenance Log
Page 38 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) Date of Service Performed By Description of Service C. Service And Maintenance Log
Page 40 - Homeowner’s Notes
Page 40 7039-131H May 5, 2011 R 2100 Millennium Wood Stove (ACC) D. Homeowner’s Notes
Page 44 - CONTACT INFORMATION; For the number of your nearest Quadra-Fire dealer,; Location on appliance:; We recommend that you record the following pertinent; DO NOT DISCARD THIS MANUAL; NOTICE; DO NOT
R Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES 7039-131H May 5, 2011 Page 44 CONTACT INFORMATION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, visit our web site at www.qu...