Page 2 - Listing Label Information/Location; Owner’s Manual; Homeowner Reference Information; NATURAL GAS; XXXXXXXX; Read this manual before installing or operating this appliance.
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealers...
Page 3 - Safety Alert Key:; Used to address practices not related to personal injury.; Table of Contents; User Guide
3 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicat...
Page 4 - B. Limited Lifetime Warranty
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 4 B. Limited Lifetime Warranty
Page 6 - Models; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; ori; Listing and Code Approvals; Standard Test Method for Behavior of Materials in a; and; National Electric Code ANSI/NFPA
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 6 C. BTU Specifi cations MODELS: QFI30, QFI35 LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Vented Gas Fireplace Heater STANDARD: ANSI Z21.88-2009 CSA 2.33-2009 Vented Gas Fireplace Heaters This product is listed to ANSI standards for “Vent...
Page 7 - Operating Instructions; WARNING! DO NOT operate fi; A. Gas Fireplace Safety; WARNING; HOT SURFACES
7 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 2 Operating Instructions Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could caus...
Page 8 - E. Fixed Glass Assembly; barrier to prevent direct contact with the; F. Remote Controls, Wall Controls and Wall; G. IPI Battery Tray/Battery Installation
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 8 C. Clear Space WARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage t...
Page 9 - I. Before Lighting Fireplace; have a; H. Control Module Operation; ame; Module Reset
9 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 Figure 2.3 Control Module NG/LP SETTING STATUS INDICATOR LED SELECTOR SWITCH FLAME HI/LO SWITCH I. Before Lighting Fireplace Before operating this fi replace for the fi rst time, have a qualifi ed technician : • Verify all shipping materials have be...
Page 10 - tery life, remove them when using the transformer.; LIGHTING; NOT FOR USE; GAS; WHAT TO DO IF YOU SMELL GAS; DO NOT CONNECT LINE VOLT-; Also Certifi ed for Installation in a; Final inspection by
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 10 J. Lighting Instructions (IPI) The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the transformer. To prolong bat- tery life, remove them when using the transformer. 1. This appliance is equipped with an ign...
Page 11 - K. After Appliance is Lit; ISSUE
11 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 Initial Break-in Procedure• The appliance should be run three to four hours continuously on high. • Turn the appliance off and allow it to completely cool.• Remove fi xed glass assembly. See Section 12.H.• Clean fi xed glass assembly. See Section ...
Page 12 - Glass Cleaning; Tools Needed; CAUTION! Handle fi xed glass assembly with care.; Note; Maintenance and Service; The appliance should be; Tools needed; Remote Control
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 12 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slammin...
Page 13 - Venting; ashing remains; Gasket Seal and Glass Assembly Inspection
13 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 Venting Frequency: Seasonally By: Homeowner Tools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, debris, etc. • Verify termination cap cleara...
Page 14 - Burner Ignition and Operation; DO NOT; ame sensing rod
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 14 Burner Ignition and Operation Frequency: Annually By: Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, fl ashlight, voltmeter, indexed drill bit set, and a manometer.• Verify burner is properly secured and aligned ...
Page 15 - A. Typical Appliance System; Illustrations and photos re; Getting Started; Installer Guide
15 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 A. Typical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual VERTICAL TERMINATION CAP...
Page 16 - B. Design and Installation Considerations; ed; D. Inspect Appliance and Components; Read all of the instructions before starting the instal-; C. Tools and Supplies Needed; Any such action may cause a fi re hazard.; DO NOT use this appliance if any part has been under
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 16 B. Design and Installation Considerations Quadra-Fire gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been installed in accordance with the National, Provin- cial, State and local building...
Page 17 - Fireplace Size Requirements; A. Minimum Fireplace Opening; Provide adequate; TOP VIEW
17 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 5 Fireplace Size Requirements Figure 5.1 Fireplace Opening In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B). E D C I F B A G H MINIMUM FIREPLACE SIZE Location QFI35 QFI30 Inches Millimeters Inches M...
Page 18 - B. Mantel and Wall Projections; • Use leveling legs to raise insert minimum 1/4 inch (6 mm)
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 18 B. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i...
Page 19 - A. Vent Termination Minimum Clearances; Termination Locations
19 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 ..................
Page 20 - Installation Preparation; A. Inspection and Cleaning; E. Electrical Outlet Box
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 20 7 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible fi rebox for installation. A. Inspection and Cleaning Prior to installing the gas insert:• Have the chimney and adjacent structure inspected and c...
Page 21 - B. Venting Components; Installing Vent Pipe and Appliance; C. Connecting Vent Pipe; • May impair safe operation of this appliance or other; Description; CAUTION! ALL vent specifi cations MUST be followed.
21 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 B. Venting Components CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. The vertical vent termination system installed on this model includes:• Flexible v...
Page 22 - ance; the
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 22 Figure 8.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top. D. Placing, Secur...
Page 23 - F. Installing Adaptor and Termination Cap; For installation of termination cap see minimum vent; Masonry; Wear protective gloves and safety glasses during instal-; Damper Flashing Kit; : Damper may have to be removed to use this kit.; system REQUIRES this insulation.; OR
23 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 F. Installing Adaptor and Termination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.4) . To install adaptor see Figure 8.5. Roof Pitch H (Min.) Ft.Flat to 6/12....................1.0*Ove...
Page 24 - Gas Information; • If substituting for these components, please consult; D. High Altitude Installations; Gas Pressure
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 24 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualifi ed technician (NFI certifi ed or factory-trained) using Hearth & Home Technologies specifi ed and approved parts. B. Ga...
Page 25 - A. Wiring Requirements; National Electric Code; Electrical Information; B. IntelliFire PlusTM Ignition System Wiring; WARNING! Risk of Shock or Explosion! DO NOT
25 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22...
Page 26 - C. Optional Accessories Requirements; Label all wires prior to dis-
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 26 Figure 10.2 Fan Wiring Diagram BLOWERS BLOWER RECEPTACLE BLKGRNBLK BLKGRNBLK WHT GRN BLK BLK GRN WHT BLK BLK BLK BLK PLUG INTO 120V EXISTING OUTLET TEMPERATURE SENSOR SWITCH VARIABLE SPEED CONTROL DC REGULATOR RECEPTACLE JUMPER WIRE PLUG 120V EX...
Page 27 - D. Fan Wiring with Remote; This appliance may be used with an RC200 or RC300; E. Control Module Operation; See Section 2.H for control module operation instructions.
27 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 PLUG 120V EXISTING OUTLET GRN (2) BLK (2) BLK (2) GRN (2) BLK (2) STEPS 3 & 4 WHT (2) BLOWER SPEED CONTROL (RHEOSTAT) SENSOR SWITCH STEPS 1 & 2 STEP 5 BLOWERS BLOWER RECEPTICLE BLKGRN BLK BLKGRN BLK WHT GRN BLK BLK GRN WHT BLK BLK PLUG I...
Page 28 - Finishing; A. Mantel and Wall Projections
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 28 11 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible...
Page 29 - inside the; E. Place the Lava Rock; Appliance Setup; DO NOT place lava rock on
29 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 A. Remove Glass Assembly See Section 12.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or undernea...
Page 30 - G. Install the Log Assembly; TINE
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 30 G. Install the Log Assembly Log Set Assembly: LOGS-QFI30 Models: QFI30 CAUTION: Logs are fragile, handle with care. Install back refractory by placing it against the back of the fi rebox. See Figure 3. The back refractory must be held in the upri...
Page 32 - rest on the burner and touches the grate bar as shown in Figure 13.
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 32 Log #4 (SRV2227-705) : Mate the slot on the bottom of the log, shown in Figure 12, with the log pin located on the burner surface. The notch on the right end of the log should mate with the grate bar. See Figure 11. Log #5 (SRV2227-706) : Place ...
Page 33 - shown in Figure 4. Repeat this step for the right refractory panel.; REFRACTORY
33 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 G. Install the Log Assembly Log Set Assembly: LOGS-QFI35 Models: QFI35 Install back refractory by placing it against the back of the fi rebox. The back refractory must be held in the upright position until the side refractory is installed. Instal...
Page 35 - between the andirons.
35 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 2225-935B Log #5 (SRV2225-710) : Position Log #5 as shown in Figure 12. Mate the middle and left log pins with the two slots located on the bottom of the log. See Figure 13 for locations of log slots. The smaller end should be pointed toward the...
Page 36 - I. Air Shutter Setting; H. Fixed Glass Assembly; DO NOT operate; Removing Fixed Glass Assembly; Air Shutter Settings; NG
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 36 I. Air Shutter Setting Air shutter settings should be adjusted by a qualifi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See...
Page 37 - Troubleshooting; arrange a service call by a qualifi ed technician.; A. IntelliFire PlusTM Ignition System; Symptom
37 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 13 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualifi ed technician in the diagnosis...
Page 38 - IntelliFire PlusTM Ignition System
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 38 Symptom Possible Cause Corrective Action 4. Pilot lights but con- tinues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame rectifi cation has not occurred.) A. A shorted or loose...
Page 39 - Reference Materials; A. Appliance Dimension Diagram
39 Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 14 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Figure 14.1 Appliance Dimensions A H B C D E I G F N M L K J O R Q P S ELECTRICAL ACCESS GAS LINE ACCESS T MODEL DIMENSIONS...
Page 40 - B. Vent Kits Components; GK to connect collinear fl ex vent to SL-D vent pipe to
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 40 Figure 14.2 Direct Vent Flex Liner Kits Figure 14.3 Direct Vent Flex Liner Accessory Kits FLASH-DAMP FLEX3-30 LINK-DV-30B (LINK-DV-30) LINK-ZC-ADP DV-46DVA-GK FLEX3-CNCT B. Vent Kits Components Direct Vent Flex Liner Kits (see Figure 14.2)LINK-D...
Page 41 - D. Contact Information; For the location of your nearest Quadra-Fire dealer,; DO NOT DISCARD THIS MANUAL; NOTICE
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11 46 Quadra-Fire, a brand of Hearth & Home Technologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www.quadrafi re.com D. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your ne...