Quadra-Fire 7023-111E - Manual

Quadra-Fire 7023-111E

Quadra-Fire 7023-111E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – and Welcome to the Quadra-Fire Family; SAMPLE OF SERIAL NUMBER / SAFETY LABEL; L E; Manufactured Date
  • Page 4 – Listing and Code Approvals; A. Appliance Certi cation; This installation must conform with local codes. In the; National; and the; CAN/CGA B149 Installation Codes; D. High Altitude Installations; WARNING; Model; F. Combustible Materials
  • Page 6 – Getting Started; and national codes and regulations.; CAUTION; B. Tools and Supplies Needed; tools will apply to every installation.; • Installation and use of any damaged appliance or vent; Any such action may cause a re hazard.; warranty will be; Report damaged parts to dealer.
  • Page 7 – Appliance Location and Clearances; A. Selecting Appliance Location
  • Page 8 – Page 8; Termination Locations; A. Vent Termination Minimum Clearances; specifi es minimum vent heights for various; • Do not pack air space with insulation or; Roof Pitch; * 3 foot minimum in snow regions
  • Page 9 – Page 9; = AREA WHERE TERMINAL IS NOT PERMITTED; public; Alcove Applications; IF EXTERIOR WALLS ARE FINISHED WITH
  • Page 10 – Vent Information; A. Venting Components; DO NOT USE FIELD-FABRICATED VENTING; • Vent this appliance directly outside.; Figure; C. Measuring Standards; ALL vent confi guration specifi cations MUST be followed.
  • Page 11 – NOTES
  • Page 12 – F. Horizontal Termination; Type A - Up and Out Installation; Female Locking Lugs; Note; : Female ends of direct vent pipe/elbows are designed
  • Page 13 – (1) The four wood screws provided should be replaced with
  • Page 14 – Local codes may require installation of a cap; Impaired Performance of Appliance.; • Ensure vent components are locked together correctly.
  • Page 15 – Check the instructions below for maximum vertical rise; NOTE; : Maximum number of 45° elbows permitted for a; G. Vertical Termination; • Do not pack air space with insulation or other
  • Page 16 – ) If an offset is necessary in the attic to avoid obstructions,; on page 8 of this manual.
  • Page 17 – • Any occupied areas above the first floor, including; For multi-story vertical installations, a ceiling firestop
  • Page 18 – Trim Collar
  • Page 19 – Class A Metal Chimney; Sheet Metal Screws; Remove existing chimney cap.
  • Page 22 – ). Mount the retro connector to the masonry wall using; wind termination cap on to the top adapter.
  • Page 23 – Gas Information; Converting to LP Gas; PROPANE
  • Page 24 – If the information in these instructions is; • Do no install a valve or regulator that has been; Valve Regulator Replacement; Disconnect any electrical cords and
  • Page 25 – • If substituting for these components, please consult local; We recommend; PRESSURE
  • Page 26 – hazard or bodily injury.
  • Page 27 – Electrical Information; A. Recommendation for Wire; DOES NOT; This appliance must be electrically wired and; National Electric Code ANSI/NFPA; or the; Canadian Electric Code, CSA; Wire Size
  • Page 28 – • Wire must have high temperature insulation.; Ignitor; Thermopile; Valve; Red
  • Page 29 – Appliance Setup; A. Remove Shipping Materials; Remove top trivet, if installed. Remove vent pipe; Sharp Edges
  • Page 30 – E. Leg Leveling System
  • Page 31 – F. Positioning the Logs; log back towards rear log until it fi ts into notch in rear log.; • Follow ember placement instructions in; Place individual pieces of embers in front of and; H. Opening Front Door
  • Page 32 – Handle glass assembly with care.; • Replace glass assembly as a complete; I. Glass Door Assembly; Do NOT use substitute material.; J. Blower Installation; FROM THE KIT YOU WILL NEED:
  • Page 33 – BLOWER; Figure 8.21 Blower Wiring Diagram
  • Page 34 – K. Damper Adjustment; OPEN
  • Page 35 – Operating Instructions; A. Before Lighting Appliance; Fumes; PILOT IGNITOR; • Keep children away.
  • Page 36 – C. Lighting Appliance; WHAT TO DO IF YOU SMELL GAS:; result causing property damage, personal injury or loss of life
  • Page 37 – D. After Appliance is Lit; Initial Break-in Procedure; E. Frequently Asked Questions; ISSUE
  • Page 38 – Troubleshooting; Symptom
  • Page 39 – Check the burner orifi ce for stoppage. Remove stoppage.
  • Page 40 – Longer operation without cleaning; When cleaning glass door:; USE CAUTION WHEN CLEANING/
  • Page 41 – USE CAUTION WHEN CLEANING/HANDLING CERAMIC BURNER.; A. Maintenance Tasks
  • Page 42 – Reference Materials; A. Appliance Dimension Diagram
  • Page 43 – B. Vent Components Diagram; Figure 12.2 SL-D Series Vent Components
  • Page 44 – C. Vent Components List
  • Page 45 – TERMINATION CAPS & KITS
  • Page 46 – Service Parts List; CASTILE GAS
  • Page 47 – Nbr
  • Page 48 – Item
  • Page 50 – Accessories
  • Page 51 – Lifetime Warranty; LIMITED LIFETIME WARRANTY
  • Page 52 – CONTACT INFORMATION; DEALERSHIP WHERE PURCHASED:; Your Records for Model:; Castile Gas; For the number of your nearest Quadra-Fire dealer; G. Contact Information
Loading the manual

www.quadrafi re.com

July 29, 2008

R

CASTILE GAS STOVE

DIRECT VENT ROOM HEATER

Owner’s Manual

Installation and Operation

Model:

7023-111E

CASTILE-GAS-MBK

CASTILE-GAS-PMH

CASTILE-GAS-CSB

CASTILE-GAS-CWL

O - T

O - T L

Tested and

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

DO NOT DISCARD THIS MANUAL

CAUTION

• Important operating and

maintenance instructions
included.

• L e a v e t h i s m a n u a l w i t h

party responsible for use
and operation.

• Read, understand and

follow these instructions
for safe installation and
operation.

• Do not store or use gasoline or other fl am-

mable vapors and liquids in the vicinity of this
or any other appliance.

• What to do if you smell gas

- D o n o t t r y t o l i g h t a n y a p p l i a n c e .

Do not touch any electrical switch. Do not
use any phone in your building.

- Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

- If you cannot reach your gas supplier, call

the fi re department.

• Installation and service must be performed

by a qualifi ed installer, service agency, or the
gas supplier.

WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.

This appliance may be installed as an OEM installation in manufactured
home (USA only) or mobile home and must be installed in accordance with
the manufacturer's instructions and the manufactured home construction and
safety standard,

Title 24 CFR, Part 3280 or Standard for Installation in Mobile

Homes, CAN/CSA Z240MH.

This appliance is only for use with the type(s) of gas indicated on the rating plate.

Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory-trained
professionals, or technicians supervised by an NFI
certifi ed professional.

DO NO

T

DISCARD

In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber or gas

fi tter.

See Table of Contents for additional Commonwealth of Mas-
sachusetts requirements.

HOT SURFACES!

Glass and other surfaces are
hot during operation AND
cool down.

WARNING

Hot glass will cause burns.

• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep

children

away

• CAREFULLY SUPERVISE children in the same room

as appliance

• Alert children and adults to hazards of high

temperatures

High temperatures may ignite clothing or other

ammable materials.

• Keep clothing, furniture, draperies and other

combustibles away.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - and Welcome to the Quadra-Fire Family; SAMPLE OF SERIAL NUMBER / SAFETY LABEL; L E; Manufactured Date

Page 2 Quadra-Fire · Castile Gas Stove · 7023-111E · July 29, 2008 and Welcome to the Quadra-Fire Family ! Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. Th...

Page 4 - Listing and Code Approvals; A. Appliance Certi cation; This installation must conform with local codes. In the; National; and the; CAN/CGA B149 Installation Codes; D. High Altitude Installations; WARNING; Model; F. Combustible Materials

Page 4 July 29, 2008 Quadra-Fire · Castile Gas Stove · 7023-111E 1 Listing and Code Approvals The product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre-ational Vehicles” and "Gas Fired Ap...

Page 6 - Getting Started; and national codes and regulations.; CAUTION; B. Tools and Supplies Needed; tools will apply to every installation.; • Installation and use of any damaged appliance or vent; Any such action may cause a re hazard.; warranty will be; Report damaged parts to dealer.

Page 6 July 29, 2008 Quadra-Fire · Castile Gas Stove · 7023-111E 2 Getting Started Check building codes prior to installation.• Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fi re offi cials or authorities having jurisdiction about...

Other Quadra-Fire Models

All Quadra-Fire Other