Page 2 - Installers Guide; DO NOT; Owners Guide; ALERTED; Safety and Warning Information
2 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 These units MUST use one of the vent systems described in the Installing the Fireplace section ofthe Installers Guide . NO OTHER vent systems or components MAY BE USED. This gas fireplace and vent assembly MUST be vented directly...
Page 3 - Table of Contents
3 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Table of Contents Safety and Warning Information .................................................. 2 Service Parts List ......................................................................... 4 Approvals and Codes ...............
Page 4 - Part number list on following page.; Log Assembly; Service Parts List
4 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Part number list on following page. 6 Log Assembly (NG, LP) Exploded Parts Diagram Service Parts List QV-Pier-HV-IPI Beginning Manufacturing Date: 6-03Ending Manufacturing Date: ______ 7 8 10 11 12 7 9 13 5 2 1 3 4
Page 5 - SERVICE PARTS LIST; supply serial and model numbers to ensure correct service parts.; ITEM
5 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 SERVICE PARTS LIST IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. ITEM COMMON PART SERIAL # ...
Page 6 - Service Parts
6 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 (NG, LP) Exploded Parts Diagram Service Parts QV-ST-HV-IPI Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ Part number list on following page. 5 Log Assembly 6 7 9 10 11 7 8 12 4 2 3 1
Page 8 - IT EM
8 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 (NG, LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ QV-PIER-HV-IPI QV-ST-HV-IPI Î Î IT EM D E S C R IP TION S E R IAL # PAR T N U MB E R 1 ON/OFF Rocker Switch 060-51...
Page 9 - Appliance Certification; The Quadra-Fire fireplace models discussed in this; Certification; Underwriters Laboratories; Installation Codes
9 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Appliance Certification The Quadra-Fire fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODELS: QV-PIER-HV-IPI, QV-ST-HV-IPI...
Page 10 - Getting Started; Introducing the Quadra-Fire Gas Fireplaces; Pre-install Preparation; Do not install any
10 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 2 Getting Started Introducing the Quadra-Fire Gas Fireplaces Quadra-Fire direct vent gas fireplaces are designed to op-erate with all combustion air siphoned from outside of thebuilding and all exhaust gases expelled to the outs...
Page 13 - Installing the Fireplace; Step 1. Locating the Fireplace; Fireplace Locations/Dimensions with
13 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 3 Installing the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require-ments for locating a fireplace within a room. Figure 4A. Fireplace Dimensions and Locations Clearance Requirements The...
Page 14 - Step 2. Framing the Fireplace
14 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Sides or Ends .......... 36 .................... 914 Floor ................................... 0 ....................... 0Rear Vent ....................
Page 15 - Model; Framing Dimensions
15 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Framing should beconstructed of 2 X 4lumber or heavier. Model A B C D E QV-PIER-HV-IPI 42-1/8 42-1/2 23 35-3/4 48 QV-ST-HV-IPI 47-5/8 42-1/2 23 35-3/4 48 Figure 5. Framing Dimensions NOTE: DIMENSIONS SHOWN IN INCHES Shows center...
Page 17 - Step 3. Installing the Vent System
17 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Figure 7. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals These models are approved to use DVP series direct ventpipe components and terminations (see Figures 6 and 7).Appr...
Page 18 - On vertical venting; Flue Restrictor Instructions; BREAK; . Center the Flue Restrictor on vent and secure in; Vertical
18 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Figure 8 NOTE: On vertical venting configurations you maywant to install the flue re-strictor (385-128). See fluerestrictor installation in-structions. Flue Restrictor Instructions 1. Locate the flue restrictor which is in the m...
Page 20 - Figure 15. Venting with Two 90° Elbows
20 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Figure 15. Venting with Two 90° Elbows H 1 H V V V 1 H NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H 1 (FT.) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914...
Page 21 - Figure 17. Venting with Two 90° Elbows
21 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Figure 16.Venting with Two 90° Elbows Figure 17. Venting with Two 90° Elbows H1 V H V H H 1 NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H 1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (9...
Page 22 - Figure 18. Venting with three 90° elbows
22 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Figure 18. Venting with three 90° elbows H H 1 H 2 V H V H 1 V 1 NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V 1 (FT.) H + H 1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m...
Page 23 - Figure 19. Venting with three 90° elbows
23 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Figure 19. Venting with three 90° elbows V H H 1 V 1 V H H 1 V 1 NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V 1 (FT.) H + H 1 (FT.) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1...
Page 24 - Venting Out Vertically
24 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 1. Attach the First Vent Component to the Starting Collars To attach the first vent component to the starting collarsof the fireplace: • Slide the first vent section onto the unit and push in until they snap lock in position. • ...
Page 27 - = AREA WHERE TERMINAL IS NOT PERMITTED; Figure 29. Vent Termination Minimum Clearances; public
27 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. Vent Termination Minimum Clearances A = 12" ....................... clearances above grade, veran- da, porch, deck or balcony B = 12...
Page 29 - Step 5. The Gas Control System; Figure 32. Gas Control System; IPI PILOT; THE FIREPLACE JUNCTION BOX IN A IPI SYSTEM.
29 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Step 4. Positioning, Leveling, and Securingthe Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, such as sheet meta...
Page 30 - Pressure; Figure 33. Gas Supply Line
30 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between thepipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hole can ...
Page 31 - Appliance Requirements
31 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensedelectrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB-SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-VENT ACCIDENTAL FIREPLACE OPERATION. For In...
Page 33 - Only non-combustible materials; F. MINIMUM SEALANT MATERIAL; Hearth Extensions; r e q u i r e h e a r t h; Figure 40. Sealant Material
33 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 QV-ST-HV-IPI TOP EDGE SIDE EDGE QV-PIER-HV-IPI TOP EDGE SIDE EDGE 0” GAP 0” GAP Step 9. Finishing Figure 38 shows the minimum vertical and corresponding maximumhorizontal dimensions of fireplace mantels or other combustibleproje...
Page 34 - overlap onto the front face. The joints; FULL OPEN; ANDIRONS; BEND TAB UNDER
34 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Installing the Trim Combustible materials may be brought up to the specifiedclearances on the side and top front edges of the fireplace,but MUST NEVER overlap onto the front face. The joints between the finished wall and the fir...
Page 36 - Placing the Ember Material; To place the ember material:; Replace the glass door and a front trim door on the unit.; Figure 53. Placement of the Ember Material
36 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Turn on the electric ember lights and paint the glass to adarkness as desired (see Figure 50). Figure 50. M a k e s u r e t o p a i n t t h e g l a s s f r o m b o t h s i d e s ( s e eFigure 51) . Figure 51. The ember bed is no...
Page 37 - Step 11. Before Lighting the Fireplace; Step 12. Lighting the Fireplace
37 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Ember Light Replacement Bulb In the lower gas valve compartment you will find three ac-cess panels for the three light bulbs (see Figure 54). Figure 54. U s i n g a 5 / 1 6 ” n u t d r i v e r r e m o v e t h e t w o b o l t s (...
Page 38 - Maintaining and Servicing Your Fireplace; Fireplace Maintenance; Placing Ember Material
38 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 4 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main-tenance will depend on use and the type of installation, youshould have a qualified service technician ...
Page 39 - Troubleshooting; Intellifire Ignition System; Symptom
39 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Troubleshooting 5 With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you doexperience a problem, this troubleshooting guide will assist a qualified service pers...
Page 40 - that wire harness is firmly connected to module.
40 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Intellifire Ignition System - (continued) Symptom Possible Causes Corrective Actions c. Module is notgrounded. Verify that module is securely grounded to metal chassis of appliance. Verify that wire harness is firmly connected t...
Page 41 - Lifetime Warranty; LIMITED LIFETIME WARRANTY
41 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06 Lifetime Warranty Î LIMITED LIFETIME WARRANTY The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work asdesigned for the lifetime of the stove or Hearth & Home Technolo...