Quadra-Fire QV36A-FB - Manual

Quadra-Fire QV36A-FB

Quadra-Fire QV36A-FB – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
Page: / 59

Table of Contents:

  • Page 2 – Congratulations; Owner’s Manual; Read this manual before installing or operating this appliance.; Homeowner Reference Information; NATURAL GAS; XXXXXXXX
  • Page 3 – Table of Contents; A. Maintenance Tasks
  • Page 4 – This installation must conform with local codes. In the; Listing and Code Approvals; B. BTU Specifi cations; TYPE: Direct Vent Gas Appliance Heater; A. Appliance Certifi cation; Material which will not ignite and burn. Such materials are; E. Combustible Materials Specifi cation; • A 110-120 VAC circuit for this product must be protected; WARNING; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; C. High Altitude Installations
  • Page 5 – T h e f o l l o w i n g r e q u i r e m e n t s r e f e r e n c e va r i o u s
  • Page 6 – A. Design and Installation Considerations; Getting Started; C. Inspect Appliance and Components; • Read all of the instructions before starting the insta-; CAUTION; Any such action may cause a fi re hazard.
  • Page 8 – Framing and Clearances; A. Selecting Appliance Location; Model
  • Page 9 – C. Mantel Projections; B. Constructing the Appliance Chase
  • Page 10 – Clearance to Combustibles; Inches; Framing should be constructed of 2 X 4 lumber
  • Page 11 – A. Vent Termination Minimum Clearances; • Do not pack air space with insulation or other; Termination Locations; Measure horizontal clearances from this surface.; • Restricted air fl ow affects burner operation.
  • Page 12 – Covered Alcove Applications; NOT
  • Page 13 – ALL vent confi guration specifi cations MUST be followed.; Vent Information and Diagrams; C. Measuring Standards; Horizontal
  • Page 14 – Must have a 12 inch minimum; One Elbow; Minimum; Minimum; * If the horizontal component is less than
  • Page 15 – Three Elbows; A section of vertical pipe (12 inches minimum)
  • Page 18 – A. Pipe Clearances to Combustibles; Vent Clearances and Framing; B. Wall Penetration Framing; Combustible Wall Penetration; • Do not pack air space with insulation or; The top standoff is fl at on top of the unit for shipping
  • Page 19 – C. Vertical Penetration Framing; Installing the Ceiling Firestop; ATTIC ABOVE; Installing Attic Shield; Fire Hazard
  • Page 20 – Appliance Preparation; rial Assembly; Gas; Sharp Edges
  • Page 21 – C. Securing and Leveling the Appliance; • Do NOT notch into the framing around the appliance spacers.
  • Page 22 – D. Installing Non-combustible Facing Material
  • Page 23 – A. Assembly of Vent Sections; Installing Vent Pipe; Attaching Vent to the Firebox Assembly; Assembling Pipe Sections; The end of the pipe sections with; Fire Risk; High Temperature Silicone Sealant; The end of the pipe sections with the lances/tabs on
  • Page 24 – INCORRECT; Assembling DVP-12A Slip Sections; Cut from this end
  • Page 25 – B. Disassembly of Vent Sections; Securing the Vent Sections; Improper support may allow vent to sag or separate.
  • Page 26 – C. Installing Heat Shield and Horizontal Termination Cap; Heat Shield Requirements for Horizontal Termination; and
  • Page 27 – D. Installing Roof Flashing and Vertical Ter-; Inspect external vent cap regularly.
  • Page 28 – Assembling and Installing Storm Collar; glasses during installation.
  • Page 29 – Gas Information; • If substituting for these components, please consult; Refer to; Reference Section 16; for location of gas line; Pressure
  • Page 30 – HIGH ALTITUDE INSTALLATIONS; • Ensure that gas line does not come in contact with outer
  • Page 31 – A. Recommendation for Wire; Electrical Information; National Electric Code ANSI/NFPA 70-latest; B. Connecting to the Appliance; EXCEPT; C. IntelliFire Ignition System Wiring; Note
  • Page 32 – LIGHT BULBS; Introduction; Installation precautions; D. Optional Accessories Requirements
  • Page 33 – Operating Instructions; For units WITH factory installed rocker switch.; The temperature displayed by the wall switch may
  • Page 34 – NOTE: The controller will turn off the fi replace at 2; When in Child Proof Mode, only the arrow buttons
  • Page 35 – F. Junction Box Installation; OUTSIDE; Do NOT wire
  • Page 36 – A. Mantel Projections; Finishing; MUST; Facing Requirements
  • Page 37 – Appliance Setup; A. Remove Shipping Materials; Placing the Ember Material; • Embers CANNOT be placed directly over ports. Care
  • Page 38 – E. Positioning the Logs
  • Page 41 – Assembly; Handle glass doors with care.; Removing Glass Assembly; Orifi ce Holder; Open Closed
  • Page 42 – I. Air Shutter Setting; This should be adjusted by a quali-
  • Page 43 – A. Before Lighting Appliance; HOT SURFACES
  • Page 44 – LIGHTING; NOT FOR USE; Final inspection by
  • Page 45 – Initial Break-in Procedure; The appliance should be run three to four hours; C. After Appliance is Lit; ISSUE
  • Page 46 – Troubleshooting; A. IntelliFire Ignition System; Symptom; Verify that 110/VAC power is “ON” to junction box.
  • Page 48 – When cleaning glass door:
  • Page 50 – Reference Materials; A. Appliance Dimension Diagram
  • Page 51 – B. Vent Components Diagrams
  • Page 52 – Horizontal Termination Cap; Max; The heat shield is designed to be; Heat
  • Page 54 – Beginning Manufacturing Date: April 2004; 6” Direct Vent Gas Fireplace; Stocked; ITEM; Log Set Assembly
  • Page 58 – This warranty is void if:; QRWOLPLWHGWRLPSURSHUFKLPQH\RUYHQWLQJLQVWDOODWLRQ; LIMITATIONS OF LIABILITY:; DWLRQRIJODVV
  • Page 59 – E. Contact Information; For the location of your nearest Quadra-Fire dealer,; DO NOT DISCARD THIS MANUAL; • Leave this manual with
Loading the manual

1

Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11

Model:
Expression 36 (QV36A-FB)

• Do not store or use gasoline or other fl am-

mable vapors and liquids in the vicinity of
this or any other appliance.

• What to do if you smell gas

- Do not try to light any appliance.

- Do not touch any electrical switch. Do not

use any phone in your building.

- Immediately call your gas supplier from a

neighbor’s phone. Follow the gas suppli-
er’s instructions.

- If you cannot reach your gas supplier, call

the fi re department.

• Installation and service must be performed

by a qualifi ed installer, service agency, or the
gas supplier.

WARNING: If the information in these

instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.

Owner’s Manual

Installation and Operation

DO NOT DISCARD THIS MANUAL

CAUTION

This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions and
the manufactured home construction and safety standard,

Title

24 CFR, Part 3280

or

Standard for Installation in Mobile Homes,

CAN/CSA Z240MH.

This appliance is only for use with the type(s) of gas indicated
on the rating plate.

• Leave this manual with

party responsible for use
and operation.

DO NO

T

DISCARD

• Important operating

a n d m a i n t e n a n c e
instructions included.

• Read, understand and follow

these instructions for safe
installation and operation.

In the Commonwealth of Massachusetts:

• installation must be performed by a licensed plumber

or gas fi tter;

S e e Ta b l e o f C o n t e n t s f o r l o c a t i o n o f a d d i t i o n a l
Commonwealth of Massachusetts requirements.

R

Para obtener un ejemplar en Español de este
Manual del propietario, visite www.heatnglo.com.

Pour demander un exemplaire en français de ce Manuel

du propriétaire, visitez www.heatnglo.com.

Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.

WARNING

This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.

HOT SURFACES

!

Glass and other surfaces are hot during
operation AND cool down.

Hot glass will cause burns.

DO NOT

touch glass until it is cooled

• NEVER allow children to touch glass
• Keep children away

• CAREFULLY SUPERVISE children in same room as

fi replace.

• Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other fl ammable
materials.

• Keep clothing, furniture, draperies and other fl ammable

materials away.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Congratulations; Owner’s Manual; Read this manual before installing or operating this appliance.; Homeowner Reference Information; NATURAL GAS; XXXXXXXX

Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11 2 Congratulations Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Dealership pur...

Page 3 - Table of Contents; A. Maintenance Tasks

3 Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11 Table of Contents 1 Listing and Code Approvals A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4B. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4C. High Altitud...

Page 4 - This installation must conform with local codes. In the; Listing and Code Approvals; B. BTU Specifi cations; TYPE: Direct Vent Gas Appliance Heater; A. Appliance Certifi cation; Material which will not ignite and burn. Such materials are; E. Combustible Materials Specifi cation; • A 110-120 VAC circuit for this product must be protected; WARNING; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; C. High Altitude Installations

Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11 4 Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada. 1 1 Lis...

Other Quadra-Fire Models

All Quadra-Fire Other