Quadra-Fire 4300 WOOD STOVE SERIES - Manual
Quadra-Fire 4300 WOOD STOVE SERIES – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – TABLE OF CONTENTS
- Page 4 – LISTINGS & SAFETY CAUTIONS; INSTALLATION MATERIALS NEEDED FOR SAFETY; WARNING! DO NOT ATTEMPT TO OPERATE THIS WOODSTOVE; NEVER DRAW
- Page 5 – SERIAL NUMBER / SAFETY LABEL LOCATION ON ALL MODELS:
- Page 6 – DIMENSIONS; CL; Back of Stove to Glass; CL; LOCATING YOUR STOVE; WHEN LOCATING YOUR STOVE; VENT SPECIFICATIONS; DS or Security DL double wall connector.
- Page 8 – edge of the opening in the face of the stove.; FLOOR PROTECTION; USA; Horizontal Venting
- Page 9 – DEFINITIONS; ALTERNATE MATERIALS WORKSHEET
- Page 10 – stove after one hour of operation at each burn setting.; NOTE; Availability of combustion air:; the requirements in your location.
- Page 11 – See Figure; FLUE SYSTEMS; ARE OTHER FACTORS THAT AFFECT FLUE DRAFT.; FIGURE 11A - Chimney Connector; CAUTION! DO NOT CONNECT THIS UNIT TO A CHIMNEY; Refer to Figure; MASONRY CHIMNEY; See Figure 11B
- Page 12 – SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE; TO COMBUSTIBLES AS REFERENCED ON PAGE 7.
- Page 13 – SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE (Cont’d)
- Page 14 – CONNECTION TO A METAL PRE-FABRICATED CHIMNEY; FIGURE 14A - INTERIOR CHIMNEY; Follow the manufacturer’s
- Page 15 – Refer to page 7; MOBILE HOME INSTALLATION
- Page 16 – ARS OPERATING AND CLEANING; NOTE LEG MODELS: DO NOT TILT THE UNIT ON THE; Disposal of Ashes; Pull down pedestal fron; LEG MODEL
- Page 17 – See; WARNING: DO NOT OPERATE STOVE BEFORE FULLY ASSEMBLING ALL
- Page 18 – INSTALLATION OF OPTIONAL BLOWER,; The blower is shipped fully assembled and ready for installation.; of the speed control.; Do not remove ground from plug.; TOP HEAT SHIELD INSTALLATION,; Set top heat shield on stove and push down into
- Page 19 – Items Needed for Installation; OUTSIDE AIR KIT INSTALLATION
- Page 20 – before reloading; OPERATING INSTRUCTIONS
- Page 21 – BUILDING A FIRE; IMPORTANT - PLEASE READ BEFORE USING STOVE
- Page 22 – set the controls as listed below:; MEDIUM LOW; BLOWER OPERATING INSTRUCTIONS; See blower installation instructions on page 18); The blower may be left on throughout the burn.; Low burn setting; with a low burn rate may adversely affect emissions.; WOOD SELECTION AND STORAGE; absorb water from rain or snow, delaying the seasoning process.
- Page 23 – DISPOSAL OF ASHES; FORMATION AND NEED FOR REMOVAL; : The creosote or soot should be removed with; NOTE: REMOVE ALL LABELS FROM GLASS BEFORE LIGHTING; CARE AND CLEANING OF PLATED SURFACES; Overfiring will void the stove warranty.
- Page 24 – BRICK REPLACEMENT INSTRUCTIONS; The Step-Top Model accepts the Ash Removal System,; GLASS REPLACEMENT; . Ensure that the fire is out and the stove is cool to the touch.
- Page 25 – FIGURE 25B - Allen wrench on retainer bolt.; DOOR HANDLE ASSEMBLY; end of the front tubes.; BAFFLE REMOVAL AND INSTALLATION; wise motion on handle leaving a 3” (76mm); SPRING HANDLE WARNING!; SEE PAGE 20 FOR OPERATING INSTRUCTIONS
- Page 26 – Ceramic Blanket; EXPLODED VIEWS; DOOR, GLASS AND DOOR HANDLE ASSEMBLY
- Page 27 – ACCESSORIES
- Page 28 – NOTES
- Page 30 – Service and Maintenance Log
- Page 31 – Lifetime Warranty
- Page 32 – CONTACT INFORMATION; Hearth & Home Technologies; instructions included.; CAUTION
4300 WOOD STOVE SERIES
Advanced Combustion Technology (ACT)
1445 North Highway
Colville, WA 99114
SAVE THESE INSTRUCTIONS
Part 250-7061C December 10, 2004
www.quadrafire.com
PRIOR TO FIRST FIRE
: Remove all labels from glass. Clean plated surfaces with a glass cleanser and soft cloth to
prevent staining from fingerprint oils.
O-T L
Tested and
Listed by
Beaverton
Oregon USA
OMNI-Test Laboratories, Inc.
C
This manual contains instructions for Installation, Operation & Maintenance. Please read this entire
manual before you install and use your new room heater. Failure to follow instructions may result in
property damage, bodily injury, or even death.
R
MILLENNIUM
STEP TOP UNI-BODY
IMPORTANT SAFETY NOTES:
1) When installing your stove, particular attention should be paid to fire protection. If this room heater is not properly
installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building,
fire officials or authority having jurisdiction about restrictions, installation inspection and permit requirements in your
area.
2) CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start
or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use.
3) During operation, if any part of the stove starts to glow, the stove is in an overfired condition. Close the air controls
completely by pulling them out, until the glowing has stopped.
OVERFIRING VOIDS YOUR WARRANTY!
4) Cool ashes should be disposed of carefully, using a metal container.
5) Do not burn wet or green wood. Store wood in a dry location.
6) DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. Do not
burn treated wood, or wood with salt (driftwood, etc.). Burning materials other than wood (including charcoal) under
adverse conditions may generate carbon monoxide in the home, resulting in illness or possible death.
7) Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.
8) Check your chimney system thoroughly when installing into an existing metal or masonry chimney. Seek profes-
sional advice if in doubt about its condition.
9) Do not connect this unit to a chimnney flue already serving another appliance.
10) Comply with all minimum clearances to combustibles as shown in this manual for this appliance.
11) Build fire on brick firebox floor. Do not use grates, andirons or other methods to support fuel.
12) HOT WHILE IN OPERATION! Keep children, pets, clothing and furniture away. Contact can cause skin burns.
13) Do not connect to any air distribution duct or system.
14) RISK OF FIRE! Do not operate with stove door or ash removal system door open.
15) For further information refer to NFPA 211 (USA) or CAN/CSA-B365 (Canada).
16) Do not operate without fully assembling all components. Burning your stove wthout the legs attached (if supplied
with unit) will void your warranty, and could present a serious safety hazard.
17) Do not operate with broken glass.
VERY IMPORTANT!!
BEFORE STARTING YOUR
FIRST FIRE READ
HOW TO OPERATE THE
2-STEP DOOR HANDLE
ON PAGE 20
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 3 250-7061C December 10, 2004 4300 ACT Wood Stove Series R MODEL NAME Uni-Body: ___Step Top ___ Millennium Serial Number Date Purchased Dealership Where Purchased Dealer Phone Additional Information: After completing your warranty card, attach your sales receipt and warranty stub here for futur...
4300 ACT Wood Stove Series Page 4 250-7061C December 10, 2004 R LISTINGS & SAFETY CAUTIONS These installation instructions describe the installation and operation of the QUADRA-FIRE 4300 woodstove. This stove meets the U.S. Environmental Protection Agency’s 1990 particulate emission standards. T...
Page 5 250-7061C December 10, 2004 4300 ACT Wood Stove Series R DIMENSIONS 26-1/2" (673mm) 34-1/4" (870mm) 10-1/2" (267mm) 15.0" (381mm) 4-3/16" (106mm) 25-3/16" (640mm) 4300 STEP TOP UNI-BODY PEDESTAL MODEL 4300 STEP TOP UNI-BODY LEG MODEL 26-1/2" (673mm) 34-1/4" (87...