Page 3 250-7061C December 10, 2004 4300 ACT Wood Stove Series R MODEL NAME Uni-Body: ___Step Top ___ Millennium Serial Number Date Purchased Dealership Where Purchased Dealer Phone Additional Information: After completing your warranty card, attach your sales receipt and warranty stub here for futur...
Page 4 - LISTINGS & SAFETY CAUTIONS; INSTALLATION MATERIALS NEEDED FOR SAFETY; WARNING! DO NOT ATTEMPT TO OPERATE THIS WOODSTOVE; NEVER DRAW
4300 ACT Wood Stove Series Page 4 250-7061C December 10, 2004 R LISTINGS & SAFETY CAUTIONS These installation instructions describe the installation and operation of the QUADRA-FIRE 4300 woodstove. This stove meets the U.S. Environmental Protection Agency’s 1990 particulate emission standards. T...
Page 5 - SERIAL NUMBER / SAFETY LABEL LOCATION ON ALL MODELS:
Page 5 250-7061C December 10, 2004 4300 ACT Wood Stove Series R DIMENSIONS 26-1/2" (673mm) 34-1/4" (870mm) 10-1/2" (267mm) 15.0" (381mm) 4-3/16" (106mm) 25-3/16" (640mm) 4300 STEP TOP UNI-BODY PEDESTAL MODEL 4300 STEP TOP UNI-BODY LEG MODEL 26-1/2" (673mm) 34-1/4" (87...
Page 6 - DIMENSIONS; CL; Back of Stove to Glass; CL; LOCATING YOUR STOVE; WHEN LOCATING YOUR STOVE; VENT SPECIFICATIONS; DS or Security DL double wall connector.
4300 ACT Wood Stove Series Page 6 250-7061C December 10, 2004 R DIMENSIONS 4300 MILLENNIUM MODEL CL 21.0" (533mm) 14-15/16" (379mm) 10-15/16" (278mm) 10-3/16" (259mm) 18.0"(457mm) 25-1/2" (648mm) 12-3/4" (324mm) 9-1/2" (241mm) 19-1/16" (484mm) 15-1/16" (383mm)...
Page 8 - edge of the opening in the face of the stove.; FLOOR PROTECTION; USA; Horizontal Venting
4300 ACT Wood Stove Series Page 8 250-7061C December 10, 2004 R FLOOR PROTECTION: Floor protector must be noncombustible material, extending beneath heater and to the front/sides/rear as indicated. The floor must be non-combustible or otherwise adequately protected from radiant heat given off by the ...
Page 9 - DEFINITIONS; ALTERNATE MATERIALS WORKSHEET
Page 9 250-7061C December 10, 2004 4300 ACT Wood Stove Series R R = x T 1 k R = x T 1 K x 12 k-factor is given with a required thickness (T) in inches: K-factor is given with a required thickness (T) in inches: r-factor is given with a required thickness (T) in inches: R = r x T R-value given - no c...
Page 10 - stove after one hour of operation at each burn setting.; NOTE; Availability of combustion air:; the requirements in your location.
4300 ACT Wood Stove Series Page 10 250-7061C December 10, 2004 R To be sure that your Quadra-Fire stove burns properly, the chimney draft (static pressure) should be approximately -.10” water column (W.C.) during a high burn and -.04” W.C. during a low burn, measured 6” (152mm) above the top of the ...
Page 11 - See Figure; FLUE SYSTEMS; ARE OTHER FACTORS THAT AFFECT FLUE DRAFT.; FIGURE 11A - Chimney Connector; CAUTION! DO NOT CONNECT THIS UNIT TO A CHIMNEY; Refer to Figure; MASONRY CHIMNEY; See Figure 11B
Page 11 250-7061C December 10, 2004 4300 ACT Wood Stove Series R There are two separate and different parts to a flue system: the chimney connector and the chimney itself. A. Single wall connector or stove pipe. This must be at least 24 gauge mild steel or 26 gauge blue steel. The sections must be at...
Page 12 - SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE; TO COMBUSTIBLES AS REFERENCED ON PAGE 7.
4300 ACT Wood Stove Series Page 12 250-7061C December 10, 2004 R FIGURE 12B SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE For the method of installation to a masonry chimney shown in Figures 14A & 14B on page 14 , it will be necessary to purchase a 12” (305mm) long 8" (203mm) inside di...
Page 13 - SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE (Cont’d)
Page 13 250-7061C December 10, 2004 4300 ACT Wood Stove Series R First, make the frame for the thimble, ensur-ing it is no smaller than 14" (356mm) square, to maintain a 2" (51mm) air space around the chimney section. Attach the wall spacer to the chimney side of the frame. Then insert the f...
Page 14 - CONNECTION TO A METAL PRE-FABRICATED CHIMNEY; FIGURE 14A - INTERIOR CHIMNEY; Follow the manufacturer’s
4300 ACT Wood Stove Series Page 14 250-7061C December 10, 2004 R * * Floor Protector Chimney Connector Combustible Ceiling Combustible Wall Insulated " T " Flashing Listed Cap Maintain 2" (51mm) Clearance Through Eave * Listed Chimney PipeChimney Connector To Stove Trim Collar on Inside ...
Page 15 - Refer to page 7; MOBILE HOME INSTALLATION
Page 15 250-7061C December 10, 2004 4300 ACT Wood Stove Series R Spark Arestor Cap Roof Flashing Storm Collar Joist Shield/Firestop Double wallconnector pipe Floor Protector Outside Air Floor Vent Outside Air Rear Vent 1. An outside air inlet must be provided for combustion and must remain clear of ...
Page 16 - ARS OPERATING AND CLEANING; NOTE LEG MODELS: DO NOT TILT THE UNIT ON THE; Disposal of Ashes; Pull down pedestal fron; LEG MODEL
4300 ACT Wood Stove Series Page 16 250-7061C December 10, 2004 R 1. Place protective pad or stove pallet on floor.2. Lay body of stove on its back on protective pad or pallet.3. Remove ash removal system top and bottom cover plates by loosening nuts under stove. Discard both plates . ASH REMOVAL SYST...
Page 17 - See; WARNING: DO NOT OPERATE STOVE BEFORE FULLY ASSEMBLING ALL
Page 17 250-7061C December 10, 2004 4300 ACT Wood Stove Series R PEDESTAL MODEL 1 Place protective pad or stove pallet on floor.2. Lay body of stove on its back on protective pad or pallet. 3. Loosen screws on adapter and slide pedestal over adapter on bottom of stove 4. Line up holes in sides of ped...
Page 18 - INSTALLATION OF OPTIONAL BLOWER,; The blower is shipped fully assembled and ready for installation.; of the speed control.; Do not remove ground from plug.; TOP HEAT SHIELD INSTALLATION,; Set top heat shield on stove and push down into
4300 ACT Wood Stove Series Page 18 250-7061C December 10, 2004 R BLOWER SPEED CONTROL Blower Mounting Flange Outer Skin INSTALLATION OF OPTIONAL BLOWER, Part 831-1701 The blower is shipped fully assembled and ready for installation. NOTE: When the speed control is turned clockwise, it will click on ...
Page 19 - Items Needed for Installation; OUTSIDE AIR KIT INSTALLATION
Page 19 250-7061C December 10, 2004 4300 ACT Wood Stove Series R (Cut-away view) FRONT COVER SIDE COVER (2) 4" (102mm) FLEX LINE (Not Included) FLEX FLANGE OUTSIDE AIR TERMINATION CAP (contains rodent screen) FIBERGLASS SEALING ROPE Included in Kit: 1 front cover; fiberglass rope; 2 vent straps; ...
Page 20 - before reloading; OPERATING INSTRUCTIONS
4300 ACT Wood Stove Series Page 20 250-7061C December 10, 2004 R START-UP AIR CONTROL PRIMARY AIR CONTROL BURNING PROCESS I n recent years there has been an increasing concern about air quality. Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order ...
Page 21 - BUILDING A FIRE; IMPORTANT - PLEASE READ BEFORE USING STOVE
Page 21 250-7061C December 10, 2004 4300 ACT Wood Stove Series R NOTE: These are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmental circumstances, this operation information is a guideline only. Similar burn rates may be obtained using oth...
Page 22 - set the controls as listed below:; MEDIUM LOW; BLOWER OPERATING INSTRUCTIONS; See blower installation instructions on page 18); The blower may be left on throughout the burn.; Low burn setting; with a low burn rate may adversely affect emissions.; WOOD SELECTION AND STORAGE; absorb water from rain or snow, delaying the seasoning process.
4300 ACT Wood Stove Series Page 22 250-7061C December 10, 2004 R OPACITY This is the measure of how cleanly your stove is burning. Opacity is measured in percent; 100% opacity is when an object is totally obscured by the smoke column from a chimney, and 0% opacity means that no smoke column can be s...
Page 23 - DISPOSAL OF ASHES; FORMATION AND NEED FOR REMOVAL; : The creosote or soot should be removed with; NOTE: REMOVE ALL LABELS FROM GLASS BEFORE LIGHTING; CARE AND CLEANING OF PLATED SURFACES; Overfiring will void the stove warranty.
Page 23 250-7061C December 10, 2004 4300 ACT Wood Stove Series R MAINTENANCE and GLASS CARE DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible ...
Page 24 - BRICK REPLACEMENT INSTRUCTIONS; The Step-Top Model accepts the Ash Removal System,; GLASS REPLACEMENT; . Ensure that the fire is out and the stove is cool to the touch.
4300 ACT Wood Stove Series Page 24 250-7061C December 10, 2004 R 1 1 3 1 1 3 1 1 1 1 1 1 1 1 4 2 2 3 3 1 1 BRICK REPLACEMENT INSTRUCTIONS The Step-Top Model accepts the Ash Removal System, and the brick pattern incorporates the ash grate. 1. After the coals have completely cooled, remove all old bri...
Page 25 - FIGURE 25B - Allen wrench on retainer bolt.; DOOR HANDLE ASSEMBLY; end of the front tubes.; BAFFLE REMOVAL AND INSTALLATION; wise motion on handle leaving a 3” (76mm); SPRING HANDLE WARNING!; SEE PAGE 20 FOR OPERATING INSTRUCTIONS
Page 25 250-7061C December 10, 2004 4300 ACT Wood Stove Series R FIGURE 25C - Baffle and Ceramic Blanket . Fiberboard Baffle Ceramic Blanket Allen wrench on retainer bolt First tube has larger holes FIGURE 25B - Allen wrench on retainer bolt. DOOR HANDLE ASSEMBLY 1. Remove all ash from the firebox, an...
Page 26 - Ceramic Blanket; EXPLODED VIEWS; DOOR, GLASS AND DOOR HANDLE ASSEMBLY
4300 ACT Wood Stove Series Page 26 250-7061C December 10, 2004 R 17.0" (432mm) 19.0" (483mm) Ceramic Blanket 1 2 3 4 5 6 7 8 9 10 11 12 Item Part Name 1 Air Control Rods 2 Ash Removal Grate 3 Ash Pan 4 Ash Removal Door 5 Baffle, Fiberboard 6 Blower Assembly 7 Ceramic Blanket 8 Door Assembly 9...
Page 27 - ACCESSORIES
Page 27 250-7061C December 10, 2004 4300 ACT Wood Stove Series R 831-1671 . . . . . . . .Ash Removal System (ARS) 831-1701 . . . . . . . .Blower Assembly 832-1092 . . . . . . . .Door Assembly, Black 832-1912 . . . . . . . .Door Assembly, Gold Trim DR-31/43NL . . . . . .Door Assembly, Nickel Trim UK-...
Page 28 - NOTES
4300 ACT Wood Stove Series Page 28 250-7061C December 10, 2004 R NOTES
Page 30 - Service and Maintenance Log
4300 ACT Wood Stove Series Page 30 250-7061C December 10, 2004 R Date of Service Performed By Description of Service Service and Maintenance Log
Page 31 - Lifetime Warranty
Page 31 250-7061C December 10, 2004 4300 ACT Wood Stove Series R LIMITED LIFETIME WARRANTY The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home Technologies will repair or replac...
Page 32 - CONTACT INFORMATION; Hearth & Home Technologies; instructions included.; CAUTION
250-7061C December 10, 2004 Page 32 R ATTENTION INSTALLERS: PLEASE RETURN THESE INSTRUCTIONS TO THE HOME OWNER WHEN THE INSTALLATION IS COMPLETE This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254...