Page 3 - Contents
Contents 3 Contents Component identification ............................................................................................................... 7 Front panel components .........................................................................................................................
Page 7 - Component identification; Front panel components
Component identification 7 Component identification Front panel components • SFF model Item Description 1 Quick release levers (2) 2 Systems Insight Display 3 Hard drive bays 4 SATA optical drive bay 5 Video connector 6 USB connectors (2) • SFF model with optional hard drive cage Item Description 1 ...
Page 8 - Front panel LEDs and buttons
Component identification 8 Item Description 6 USB connectors (2) • LFF model Item Description 1 Quick release levers (2) 2 Systems Insight Display 3 Hard drive bays 4 USB connectors (2) 5 Video connector Front panel LEDs and buttons Item Description Status 1 UID LED and button Blue = Activated Flash...
Page 9 - Systems Insight Display LEDs
Component identification 9 Item Description Status 2 System health LED Green = Normal Amber = System degraded. Red = System critical. To identify components in degraded or critical state, see "Systems Insight Display LEDs (on page 9 )." 3 Power On/Standby button and system power LED Green = ...
Page 10 - Systems Insight Display LED combinations
Component identification 10 Item Description Status 1 NIC link/activity LED Green = Network link Flashing green = Network link and activity Off = No link to network. If the power is off, view the rear panel RJ-45 LEDs for status (" Rear panel LEDs and buttons " on page 12 ) 2 Power cap To de...
Page 11 - Rear panel components
Component identification 11 Systems Insight Display LED and color Health LED System power LED Status Power supply (amber) Red Amber • Only one power supply is installed and that power supply is in standby. • Power supply fault • System board fault Power supply (amber) Amber Green • Redundant power s...
Page 12 - Non-hot-plug PCI riser board slot definitions
Component identification 12 10 Video connector 11 NIC 1 connector 12 NIC 2 connector 13 Mouse connector 14 Keyboard connector 15 Serial connector 16 iLO 3 connector 17 NIC 3 connector 18 NIC 4 connector Rear panel LEDs and buttons Item Description Status 1 Power supply LED Green = Normal Off = Syste...
Page 14 - System board components
Component identification 14 System board components Item Description 1 Processor 2 DIMM slots 2 SAS power connector A 3 SAS power connector B 4 Front I/O connector 5 SATA optical drive connector 6 Internal USB connector 7 System battery 8 Power supply backplane connector 9 NMI jumper 10 System maint...
Page 15 - System maintenance switch; NMI functionality
Component identification 15 Item Description 18 SAS connector A 19 SAS connector B 20 Cache module connector 21 Fan connector 1 22 Fan connector 2 23 Fan connector 3 24 Fan connector 4 25 Fan connector 5 26 Fan connector 6 System maintenance switch Position Default Function S1 Off Off = iLO 3 securi...
Page 16 - DIMM slot locations
Component identification 16 problem analysis, but the NMI feature preserves that information by performing a memory dump before a hard reset. To force the OS to invoke the NMI handler and generate a crash dump log, the administrator can do any of the following: • Short the NMI jumper pins • Press th...
Page 17 - SAS and SATA device numbers
Component identification 17 SAS and SATA device numbers • SFF device bay numbering • Optional SFF device bay numbering • LFF device bay numbering
Page 18 - SAS and SATA hard drive LEDs; SAS and SATA hard drive LED combinations
Component identification 18 SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA hard drive LED combinations Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation On, off, or flashing Alternating amber and blue The drive has fai...
Page 19 - PCI riser cage LEDs
Component identification 19 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Off Steadily amber A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible. Off Amber, flashing regularly (1 Hz) A ...
Page 20 - FBWC module LEDs
Component identification 20 FBWC module LEDs The FBWC module has two single-color LEDs (green and amber). The LEDs are duplicated on the reverse side of the cache module to facilitate status viewing. Green LED Amber LED Interpretation Off On A backup is in progress. Flashing (1 Hz) On A restore is i...
Page 21 - Battery pack LEDs
Component identification 21 Battery pack LEDs Item ID Color Description 1 Green System Power LED. This LED glows steadily when the system is powered up and 12 V system power is available. This power supply is used to maintain the battery charge and provide supplementary power to the cache microcontr...
Page 24 - Operations; Power up the server
Operations 24 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the server WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/St...
Page 25 - Remove the access panel
Operations 25 3. After performing the installation or maintenance procedure, slide the server back into the rack, and then press the server firmly into the rack to secure it in place. WARNING: To reduce the risk of personal injury, be careful when pressing the server rail-release latches and sliding...
Page 26 - Install the access panel; Cable management arm with left-hand swing
Operations 26 1. Power down the server if performing a non-hot-plug installation or maintenance procedure (" Power down the server " on page 24 ). 2. Extend the server from the rack (on page 24 ). 3. Use the T-15 Torx screwdriver attached to the rear of the server to loosen the security scre...
Page 27 - Cable management arm with right-hand swing
Operations 27 2. Open the cable management arm. Cable management arm with right-hand swing NOTE: To access some components, you may need to remove the cable management arm. To access the product rear panel components, open the cable management arm: 1. Power down the server (on page 24 ). 2. Swing op...
Page 28 - Remove the full-length expansion board retainer
Operations 28 Remove the full-length expansion board retainer CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the PCI riser cage. 1. Power down the server (on page 24 ). 2. Extend the server from the rack...
Page 29 - Remove the PCI riser cage
Operations 29 Remove the PCI riser cage CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the PCI riser cage. 1. Power down the server (on page 24 ). 2. Extend the server from the rack (on page 24 ). 3. Rem...
Page 30 - Install the full-length expansion board retainer
Operations 30 4. Install the PCI riser cage. 5. Install the access panel (on page 26 ). 6. Install the server into the rack (" Installing the server into the rack " on page 35 ). 7. Power up the server (on page 24 ). Install the full-length expansion board retainer 1. Power down the server (...
Page 31 - Remove the air baffle
Operations 31 7. Install the server into the rack (" Installing the server into the rack " on page 35 ). 8. Power up the server (on page 24 ). Remove the air baffle CAUTION: For proper cooling do not operate the server without the access panel, baffles, expansion slot covers, or blanks insta...
Page 32 - Setup; Optional installation services
Setup 32 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a ...
Page 33 - Optimum environment; Space and airflow requirements
Setup 33 Optimum environment When installing the server in a rack, select a location that meets the environmental standards described in this section. Space and airflow requirements To allow for servicing and adequate airflow, observe the following space and airflow requirements when deciding where ...
Page 34 - Temperature requirements; Power requirements; Electrical grounding requirements
Setup 34 Temperature requirements To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated, climate-controlled environment. The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C (95°F). The temperature in t...
Page 37 - Installing the operating system; Powering up and configuring the server
Setup 37 6. Connect the power cord to the AC power source. WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature. • Plug the power cord into a grounded (earthed) electrical outlet th...
Page 38 - Registering the server
Setup 38 To configure these utilities manually: • Press the F8 key when prompted during the array controller initialization to configure the array controller using ORCA. • Press the F9 key when prompted during the boot process to change the server settings using RBSU. The system is set up by default...
Page 39 - Hardware options installation; Introduction
Hardware options installation 39 Hardware options installation Introduction If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process. WARNING: To reduce the risk of personal injury fr...
Page 46 - Memory options; Memory subsystem architecture
Hardware options installation 46 Memory options IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the server to halt during BIOS initialization. The memory subsystem in this server can support RDIMMs or UDIMMs. Both types are referred to as DI...
Page 47 - DIMM identification; Memory configurations
Hardware options installation 47 Dual- and quad-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if current DRAM technology supports 2-GB single-rank DIMMs, a dual-rank DIMM would be 4-GB, and a quad-rank DIMM would be 8-GB. DIMM identification To determine ...
Page 48 - RDIMM maximum memory configurations; UDIMM maximum memory configurations
Hardware options installation 48 • Lockstep—provides enhanced protection over Advanced ECC mode while continuing to make all installed memory available to the operating system. The server can continue to function if a single- or mulit-bit memory failure within a single DRAM device occurs. • Online s...
Page 49 - Online Spare memory configuration; General DIMM slot population guidelines; Advanced ECC population guidelines
Hardware options installation 49 Lockstep mode uses channel 1 and channel 2. Channel 3 is not populated. Because channel 3 cannot be populated when using Lockstep mode, the maximum memory capacity is lower than Advanced ECC mode. Memory performance with Advanced ECC is also slightly higher. Online S...
Page 50 - Single-processor Advanced ECC population order; Lockstep Memory population guidelines; Single-processor Lockstep population order
Hardware options installation 50 • Observe the general DIMM slot population guidelines (on page 49 ). • DIMMs may be installed individually. Single-processor Advanced ECC population order For Advanced ECC mode configurations with a single processor, populate the DIMM slots in the following order: • ...
Page 51 - Multi-processor Lockstep population order; Online Spare population guidelines; Single-processor Online Spare population order
Hardware options installation 51 Multi-processor Lockstep population order For Lockstep memory mode configurations with multiple processors, populate the DIMM slots for each processor in the following order: • RDIMM o First: A and B o Next: D and E o Last: G and H o Do not populate slots C, F, or I....
Page 52 - Multi-processor Online Spare population order; Mirrored Memory population guidelines; Single-processor Mirrored Memory population order
Hardware options installation 52 Multi-processor Online Spare population order For Online Spare mode configurations with a multiple processors, populate the DIMM slots for each processor in the following order: • RDIMM o First: A, B, and C o Next: D, E, and F o Last: G, H, and I • UDIMM o First: A, ...
Page 53 - Multi-processor Mirrored Memory population order; Installing a DIMM
Hardware options installation 53 Multi-processor Mirrored Memory population order For Mirrored Memory mode configurations with multiple processors, populate the DIMM slots for each processor in the following order: • RDIMM o First: A and B o Next: D and E o Last: G and H o Do not populate slots C, F...
Page 54 - Hot-plug SAS hard drive options; Installing a hot-plug SAS hard drive
Hardware options installation 54 9. If removed, install the BBWC battery pack or the FBWC capacitor pack. 10. Install the access panel (on page 26 ). If you are installing DIMMs in online spare, mirrored, or lock-step configuration, configure this mode in RBSU (" HP ROM-Based Setup Utility "...
Page 55 - Removing a hot-plug SAS hard drive; Flash-backed write cache module option
Hardware options installation 55 3. Install the hard drive. 4. Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations (" SAS and SATA hard drive LED combinations " on page 18 ). Removing a hot-plug SAS hard drive CAUTION: For proper cooling do not operate th...
Page 57 - Optical drive option
Hardware options installation 57 10. Attach the capacitor pack to the air baffle. 11. Install the PCI riser cage (on page 29 ). 12. Install the full-length expansion board retainer (on page 30 ) if any full-length expansion boards are installed. 13. Install the access panel (on page 26 ). 14. Instal...
Page 59 - Redundant hot-plug power supply option
Hardware options installation 59 7. Connect the power and data cable to the optical drive. 8. Install the access panel (on page 26 ). 9. Power up the server (on page 24 ). Redundant hot-plug power supply option CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless...
Page 60 - Expansion board options; Removing expansion slot covers
Hardware options installation 60 3. Install the power supply in the power supply bay. 4. Connect the power cord to the power supply. 5. Route the power cord through the power cord anchor or cable management arm. 6. Reposition the cable management arm into the operating position. 7. Connect the power...
Page 62 - Installing a half-length expansion board; Installing a full-length expansion board
Hardware options installation 62 o To remove slot covers 5 and 6, push down on the latch, rotate the latch down, and then remove the cover. Installing a half-length expansion board 1. Power down the server (on page 24 ). 2. Extend the server from the rack (on page 24 ). 3. Remove the access panel (o...
Page 63 - PCI riser board option
Hardware options installation 63 7. Connect any required internal or external cables to the expansion board. See the documentation that ships with the expansion board. 8. Install the PCI riser cage (on page 29 ). 9. Install the full-length expansion board retainer (on page 30 ). 10. Install the acce...
Page 64 - Hard drive cage option
Hardware options installation 64 Hard drive cage option Installation of a SAS expander card or an additional SAS controller option is required to support the hard drive cage option. 1. Power down the server (on page 24 ). 2. Extend the server from the rack (on page 24 ). 3. Remove the access panel (...
Page 65 - HP Trusted Platform Module option
Hardware options installation 65 8. Install the hard drives (" Hot-plug SAS hard drive options " on page 54 ). 9. Install the hard drive blanks. 10. Remove the full-length expansion board retainer (on page 28 ) if any full-length expansion boards are installed. 11. Remove the PCI riser cage ...
Page 66 - Installing the Trusted Platform Module board
Hardware options installation 66 Enabling the TPM requires accessing the ROM-Based Setup Utility (RBSU) (" HP ROM-Based Setup Utility " on page 72 ). For more information about RBSU, see the HP website
Page 68 - Retaining the recovery key/password
Hardware options installation 68 Retaining the recovery key/password The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after BitLocker™ is enabled. When using BitLocker™, always retain the recovery key/password. The recovery key/password is required to ente...
Page 69 - Cabling; SAS hard drive cabling
Cabling 69 Cabling SAS hard drive cabling Optical drive cabling
Page 71 - Configuration and utilities; Configuration tools; SmartStart software; SmartStart Scripting Toolkit
Configuration and utilities 71 Configuration and utilities Configuration tools SmartStart software SmartStart is a collection of software that optimizes single-server setup, providing a simple and consistent way to deploy server configuration. SmartStart has been tested on many ProLiant server produ...
Page 72 - HP ROM-Based Setup Utility; Using RBSU; Auto-configuration process
Configuration and utilities 72 refer to the SmartStart Scripting Toolkit User Guide on the HP website
Page 73 - Boot options; Configuring AMP modes
Configuration and utilities 73 NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the array. You must run ORCA to configure the array settings. Drives installed Drives used RAID level 1 1 RAID 0 2 2 RAID 1 3, 4, 5, or 6 3, 4, 5, or 6 RAID 5...
Page 74 - Configuring Advanced ECC memory; Configuring online spare memory; Configuring mirrored memory
Configuration and utilities 74 uncorrectable memory error occurs, the system automatically retrieves the good data from the mirrored copy. The system continues to operate normally without any user intervention. If the system supports hot-plug memory, the failed memory can be replaced while the syste...
Page 75 - Configuring lockstep memory; Array Configuration Utility
Configuration and utilities 75 For more information on mirrored memory, see the white paper on the HP website
Page 76 - Re-entering the server serial number and product ID; Management tools; Automatic Server Recovery
Configuration and utilities 76 • Reconfiguring one or more logical drives • Viewing the current logical drive configuration • Deleting a logical drive configuration • Setting the controller to be the boot controller If you do not use the utility, ORCA will default to the standard configuration. For ...
Page 77 - ROMPaq utility; Erase Utility
Configuration and utilities 77 ASR increases server availability by restarting the server within a specified time after a system hang or shutdown. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable AS...
Page 78 - Redundant ROM support; Safety and security benefits; USB support and functionality; USB support
Configuration and utilities 78 CAUTION: Perform a backup before running the System Erase Utility. The utility sets the system to its original factory state, deletes the current hardware configuration information, including array setup and disk partitioning, and erases all connected hard drives compl...
Page 79 - Internal USB functionality; Internal SD support; Diagnostic tools; HP Insight Diagnostics; Integrated Management Log
Configuration and utilities 79 Internal USB functionality An internal USB connector is available for use with security key devices and USB drive keys. This solution provides for use of a permanent USB key installed in the internal connector, avoiding issues of clearance on the front of the rack and ...
Page 80 - Remote support and analysis tools; HP Insight Remote Support software; Keeping the system current; Drivers
Configuration and utilities 80 You can view recorded events in the IML in several ways, including the following: • From within HP SIM • From within Survey Utility • From within operating system-specific IML viewers o For NetWare: IML Viewer o For Windows®: IML Viewer o For Linux: IML Viewer Applicat...
Page 81 - Version control; ProLiant Support Packs
Configuration and utilities 81 If you are installing a SmartStart-supported OS, use the SmartStart software (on page 71 ) and its Assisted Path feature to install the OS and latest driver support. If you are installing drivers from the SmartStart CD, be sure that you are using the latest SmartStart ...
Page 82 - HP Smart Update Manager; Change control and proactive notification
Configuration and utilities 82 • The HP BladeSystem online firmware bundles • The ProLiant BladeSystem Release Sets • Offline, automatic mode for HP ProLiant BL, DL, ML, and 100 Series servers • Firmware deployment support for HP ProLiant 100 Series servers HP Smart Update Manager The HP Smart Updat...
Page 83 - Troubleshooting; Troubleshooting resources; Pre-diagnostic steps; Important safety information
Troubleshooting 83 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, error message interpretation, issue resolution, and software mainte...
Page 84 - Symbols on equipment
Troubleshooting 84 Symbols on equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions. This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel. WARNING: To re...
Page 85 - Symptom information
Troubleshooting 85 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature. • Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times. • ...
Page 86 - Breaking the server down to the minimum hardware configuration
Troubleshooting 86 2. Record any error messages displayed by the system. 3. Remove all diskettes, CD-ROMs, DVD-ROMs, and USB drive keys. 4. Power down the server and peripheral devices if you will be diagnosing the server offline. If possible, always perform an orderly shutdown: a. Exit any applicat...
Page 87 - Loose connections
Troubleshooting 87 When requested to break the server down to the minimum configuration, uninstall the following components, if installed: • All additional DIMMs Leave only the minimum required to boot the server—either one DIMM or a pair of DIMMs. For more information, see the memory guidelines in ...
Page 88 - Service notifications; Server health LEDs; Start diagnosis flowchart
Troubleshooting 88 Service notifications To view the latest service notifications, refer to the HP website
Page 89 - General diagnosis flowchart
Troubleshooting 89 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if the other flowcharts do not fix the problem, use the following flowchart. Item See 1 "Symptom information (on page 85 )" 2 ...
Page 94 - POST problems flowchart
Troubleshooting 94 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system attempts to access the boot device. • Server completes POST with errors Possible problems: • Improperly seated or faulty internal component • Faulty KVM device • F...
Page 96 - OS boot problems flowchart
Troubleshooting 96 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot SmartStart Possible causes: • Corrupted operating system • Hard drive subsystem problem • Incorrect boot order setting in RBSU Item See 1 HP ROM-Based Setup U...
Page 97 - Server fault indications flowchart
Troubleshooting 97 Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents • Server boots, but the internal health LED, external health LED, or component health LED is red or amber NOTE: For the location of server LEDs and information o...
Page 99 - POST error messages and beep codes
Troubleshooting 99 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website
Page 101 - Battery replacement
Battery replacement 101 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alka...
Page 102 - Regulatory compliance notices; Regulatory compliance identification numbers; Federal Communications Commission notice; FCC rating label
Regulatory compliance notices 102 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the pr...
Page 103 - Modifications
Regulatory compliance notices 103 radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the u...
Page 104 - European Union regulatory notice
Regulatory compliance notices 104 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Class B equipment This Class B di...
Page 105 - Japanese notice
Regulatory compliance notices 105 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recy...
Page 106 - Chinese notice; Laser compliance
Regulatory compliance notices 106 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Pr...
Page 107 - Taiwan battery recycling notice
Regulatory compliance notices 107 For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of...
Page 108 - Electrostatic discharge; Preventing electrostatic discharge
Electrostatic discharge 108 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boa...
Page 109 - Specifications; Environmental specifications; Mechanical specifications; Power supply specifications
Specifications 109 Specifications Environmental specifications Specification Value Temperature range* Operating 10 ° C to 35 ° C (50 ° F to 95 ° F) Shipping -30 ° C to 50 ° C (-22 ° F to 122 ° F) Storage -30°C to 60°C (-22°F to 140°F) Maximum wet bulb temperature 28 ° C (82.4 ° F) Relative humidity ...
Page 112 - Technical support; Before you contact HP
Technical support 112 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical support registration number (if applicable) • Product serial number • Product model name and number • Product identification number • Applicable error mes...
Page 114 - Riparazione da parte del cliente
Technical support 114 Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Rep...
Page 120 - Acronyms and abbreviations
Acronyms and abbreviations 120 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR Automatic Server Recovery BBWC battery-backed write cache CSA Canadian Standards Association CSR Customer Self Repair DDR double data rate IEC International...
Page 123 - Index
Index 123 A access panel 25, 26 Advanced ECC memory 48, 49, 73, 74 air baffle 31 Array Configuration Utility (ACU) 75 ASR (Automatic Server Recovery) 76 authorized reseller 112 auto-configuration process 72 Automatic Server Recovery (ASR) 76 B battery 15, 101, 106 battery cabling for BBWC 70 battery...