HP DL385 - Manual

HP DL385

HP DL385 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
146 Page 146
147 Page 147
148 Page 148
149 Page 149
150 Page 150
151 Page 151
152 Page 152
153 Page 153
154 Page 154
155 Page 155
156 Page 156
157 Page 157
158 Page 158
159 Page 159
160 Page 160
161 Page 161
162 Page 162
163 Page 163
164 Page 164
165 Page 165
166 Page 166
167 Page 167
168 Page 168
169 Page 169
170 Page 170
171 Page 171
172 Page 172
173 Page 173
174 Page 174
Page: / 174

Table of Contents:

  • Page 3 – Contents; Server component identification
  • Page 4 – Server setup
  • Page 5 – Server cabling
  • Page 6 – Battery replacement
  • Page 7 – Regulatory compliance notices
  • Page 9 – In this section
  • Page 10 – Front panel components
  • Page 11 – Front panel LEDs and buttons
  • Page 12 – Rear panel components
  • Page 13 – Rear panel LEDs and buttons
  • Page 14 – System board components
  • Page 15 – System maintenance switch
  • Page 16 – NMI jumper
  • Page 17 – DIMM slots
  • Page 18 – SCSI backplane components
  • Page 19 – SAS backplane components
  • Page 20 – System board LEDs
  • Page 22 – System LEDs and internal health LED combinations
  • Page 23 – SCSI backplane LEDs
  • Page 24 – Hot-plug SCSI hard drive LEDs
  • Page 25 – Hot-plug SCSI hard drive LED combinations
  • Page 26 – Hot-plug SAS hard drive LEDs; Hot-plug SAS hard drive LED combinations
  • Page 28 – PCI riser cage LED
  • Page 29 – Remote management connector; Identifying hot-plug fans
  • Page 31 – Power converter module LED
  • Page 32 – Battery-backed write cache LEDs; Battery-backed write cache LED statuses
  • Page 35 – Server operations; Powering up the server
  • Page 37 – Extending the server from the rack
  • Page 38 – Removing the access panel
  • Page 39 – Installing the access panel; Cable management arm with left-hand swing; Cable management arm with right-hand swing
  • Page 40 – Removing the PCI riser cage
  • Page 41 – Installing the PCI riser cage
  • Page 43 – Front fan bracket
  • Page 45 – Optional installation services
  • Page 46 – Rack planning resources; Space and airflow requirements
  • Page 48 – Temperature requirements; Power requirements
  • Page 49 – Electrical grounding requirements
  • Page 50 – Rack warnings
  • Page 51 – Identifying the contents of the server shipping carton
  • Page 52 – Installing hardware options
  • Page 55 – Powering up and configuring the server
  • Page 56 – Installing the operating system
  • Page 57 – Hardware options installation; Introduction
  • Page 58 – Processor option
  • Page 62 – Memory options; DIMM installation guidelines
  • Page 63 – Installing DIMMs
  • Page 64 – Hot-plug SCSI hard drive options
  • Page 65 – SCSI IDs
  • Page 66 – Installing a hot-plug SCSI hard drive
  • Page 67 – Removing a hot-plug SCSI hard drive
  • Page 68 – Power supply blank; SAS drive numbers
  • Page 69 – Installing a hot-plug SAS hard drive
  • Page 70 – Removing a hot-plug SAS hard drive
  • Page 71 – Installing a diskette drive
  • Page 73 – Hot-plug tape drive option
  • Page 74 – Redundant hot-plug fans
  • Page 75 – Hot-plug fan installation requirements
  • Page 76 – Installing redundant hot-plug fans
  • Page 77 – Battery-backed write cache option
  • Page 80 – Redundant hot-plug AC power supply option
  • Page 81 – Expansion board options
  • Page 85 – Cabling
  • Page 86 – SAS hard drive cabling
  • Page 87 – USB cabling
  • Page 88 – Diskette drive cabling
  • Page 89 – Power button/LED cabling
  • Page 90 – Internal power cabling; SCSI model cabling
  • Page 91 – Embedded simplex SCSI cabling
  • Page 92 – Embedded duplex SCSI cabling
  • Page 93 – PCI simplex SCSI cabling
  • Page 94 – PCI duplex SCSI cabling; Mixed duplex SCSI cabling
  • Page 96 – Installing the SCSI terminator board
  • Page 97 – Removing the SCSI terminator board
  • Page 103 – Server software and configuration utilities; Configuration tools; SmartStart software
  • Page 104 – SmartStart Scripting Toolkit
  • Page 105 – Configuration Replication Utility; ROM-based enhancements overview
  • Page 106 – Using RBSU; To make selections, press the Enter key.
  • Page 107 – Boot options
  • Page 108 – Array Configuration Utility
  • Page 109 – HP ProLiant Essentials Rapid Deployment Pack; During the server startup sequence, press the F9 key to access RBSU.
  • Page 110 – Enter the product ID and press the Enter key.; Management tools; Automatic Server Recovery
  • Page 111 – ROMPaq utility
  • Page 112 – Integrated Lights-Out technology; Erase Utility
  • Page 113 – ) or the Maintenance Utilities menu of; StorageWorks library and tape tools
  • Page 114 – Redundant ROM support; Safety and security benefits
  • Page 115 – System maintenance menu
  • Page 116 – iLO ROM-Based Setup Utility; Press the F8 key when prompted during POST. The iLO RBSU runs.
  • Page 117 – USB support; Diagnostic tools
  • Page 118 – Survey Utility; HP Insight Diagnostics
  • Page 119 – Integrated Management Log; Keeping the system current
  • Page 120 – Drivers; Resource Paqs
  • Page 121 – Operating system version support; Change control and proactive notification; Care Pack
  • Page 125 – Troubleshooting; Troubleshooting resources; Server diagnostic steps
  • Page 126 – Important safety information
  • Page 128 – Warnings and cautions
  • Page 130 – Preparing the server for diagnosis; Symptom information
  • Page 131 – Service notifications
  • Page 132 – Diagnostic steps; Start diagnosis flowchart
  • Page 134 – General diagnosis flowchart
  • Page 136 – Power-on problems flowchart
  • Page 139 – POST problems flowchart
  • Page 142 – OS boot problems flowchart
  • Page 145 – Server fault indications flowchart
  • Page 148 – POST error messages and beep codes; Introduction to POST error messages; Node Interleaving disabled - Invalid memory configuration
  • Page 149 – Processor Reduced Power Mode Enabled in RBSU
  • Page 150 – Description: Unsupported memory types found in system.
  • Page 151 – WARNING - Resetting Corrupted NVRAM
  • Page 153 – Electrostatic discharge; Preventing electrostatic discharge
  • Page 155 – Federal Communications Commission notice; FCC rating label
  • Page 156 – Class A equipment
  • Page 157 – Modifications
  • Page 158 – Laser compliance
  • Page 159 – European Union regulatory notice
  • Page 160 – Japanese notice
  • Page 161 – Battery replacement notice
  • Page 162 – Taiwan battery recycling notice
  • Page 163 – Server specifications
  • Page 164 – Environmental specifications
  • Page 165 – Technical support; Related documents
  • Page 166 – Customer self repair
  • Page 167 – Acronyms and abbreviations
  • Page 171 – Index
Loading the manual
Page 1

HP ProLiant DL385 Server

User Guide

March 2005 (Second Edition)

Part Number 376536-002

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
HP
Model
DL385
Document type
Manual
Language(s)
English
Pages
174
File size
7.1 MB
Format
PDF

Summary

Page 3 - Contents; Server component identification

3 Contents Server component identification 9 Front panel components ..................................................................................................................... 10 Front panel LEDs and buttons......................................................................................

Page 4 - Server setup

4 HP ProLiant DL385 Server User Guide Front fan bracket ................................................................................................................................ 43 Server setup 45 Optional installation services ....................................................................

Page 5 - Server cabling

Contents 5 Server cabling 85 Cabling ............................................................................................................................................... 85 SAS model cabling .....................................................................................................

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.