Page 3 - ESS – Enterprise Server & Storage; The best high-volume AND high-value solutions; HP ProLiant; Infrastructure Software
HP Confidential NDA required ESS – Enterprise Server & Storage The best high-volume AND high-value solutions HP ProLiant HP Integrity/Integrity NonStop HP BladeSystem HP StorageWorks Infrastructure Software
Page 4 - HP ProLiant Server Familie; HP BladeSystem
HP Confidential NDA required HP ProLiant Server Familie DL585 300 ML350 ML370 DL380 DL320 DL360 ML150 ML110, ML115 DL120, DL160, DL180 100 DL165, DL185 500 DL580 HP BladeSystem DL385 ML310 DL365 DL785 700
Page 5 - HP ProLiant Server Linien; Industry Standard tools for an Adaptive Enterprise; ProLiant Enablers; ML; Linux
HP Confidential NDA required HP ProLiant Server Linien Industry Standard tools for an Adaptive Enterprise ProLiant Enablers ProLiant Essentials Universal Smart Array storage, rack and power HP ProLiant BL Maximum flexibility and control HP ProLiant DL Density-optimized for rack mount environments HP...
Page 6 - Weltweiter x86 Market share; HP; Units; Dell; Sun
HP Confidential NDA required Weltweiter x86 Market share 0% 5% 10% 15% 20% 25% 30% 35% 40% HP Units Revenue Dell IBM Whitebox Sun Source : IDC Worldwide Quarterly Server Tracker: 4Q07, February 26, 2008
Page 7 - Österreich x86 Market Share
HP Confidential NDA required Österreich x86 Market Share 7 0,0% 10,0% 20,0% 30,0% 40,0% 50,0% 60,0% Q2 2006 Q3 2006 Q4 2006 Q1 2007 Q2 2007 Q3 2007 Q4 2007 Q1 2008 Units HP Fujitsu Dell IBM Maxdata Others
Page 8 - x86 Mkt Share Evolution – Blades Units; Austria
HP Confidential NDA required x86 Mkt Share Evolution – Blades Units Austria Source: IDC_Qshare_Q408_EMEA_HP.xls
Page 9 - ProLiant enterprise server line-up; Intel Xeon-based systems
HP Confidential NDA required ProLiant enterprise server line-up ML350 ML370 DL380 DL360 DL580 Intel Xeon-based systems ML350 Best Selling Tower Server DL360 Best Selling 1U Server ML370 Best Performing 2P x86 DL380 #1 Server World Wide DL580 #1 4-socket server Branch Office & Enterprise Minded S...
Page 10 - The HP BladeSystem Enclosure portfolio
HP Confidential NDA required The HP BladeSystem Enclosure portfolio Time-Smart, Energy-Efficient, Cost-savvy 2006 September 2007 Rack-able or set on a table c3000 Place on a floor using the Tower version C3000 Tower Datacenter optimized c7000 Holds 16 c- Class server blades Holds 8 c-Class server bl...
Page 11 - Customers win with HP Thermal Logic; less power; Blades benötigen
HP Confidential NDA required HP BL460c (Intel 5140 dual-core) Power: 2720 VA @100% CPU Util. Cooling: 172 CFM Acoustics: 7.4 bels 8 x1U severs Power: 3856 VA @100% CPU Util. Cooling: 323 CFM Acoustics: 8.1 bels 8 HP c-Class servers Assumptions: • Same load/same configuration (2 x 5140 CPU w/ 8 DIMMs...
Page 14 - HP BladeSystem c-Class Portfolio; A Full Range of 2P and 4P Blades; Server Blades; Storage; Unified Management
HP Confidential NDA required HP BladeSystem c-Class Portfolio A Full Range of 2P and 4P Blades Interconnect choices for LAN, SAN, and Scale-Out Clusters Virtual Connect LAN Ethernet NICs SAN Fibre Channel InfiniBand 4X DDR h h h h Server Blades Workstation Blades Storage Blades Unified Management Ch...
Page 15 - HP ProLiant G6
© 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice HP ProLiant G6
Page 16 - Leading Efficiency; Increased Power Efficiency over
HP Confidential NDA required Leading Efficiency • Control your power budget • Dynamic power capping • Conserve energy Increased Power Efficiency over G5 • Energy Star rated • All power supplies are up to 92% efficient • SpecPower Leadership Right-sized Power Supplies • Only pay for the power you nee...
Page 17 - Continued Leadership in Energy Efficiency; efficiency; Power
HP Confidential NDA required Continued Leadership in Energy Efficiency • Dynamic Power Capping • Intelligent Power & Cooling Savers o Sea of Sensors o Power Down Mode Support on DDR-3 o Dynamic Power Management of unused i/o ports. o Individual Fan Management for Dynamic cooling and power manage...
Page 18 - G6 Common Slot Power Strategy
HP Confidential NDA required 18 G6 Common Slot Power Strategy • Right-Sized to reclaim wasted/lost power in the rack. Reclaim power with just the size power supply you need. • Improved power efficiencies up to 90% and 92%, which are targets for Energy Star • Meets requirements for SpecPower leadersh...
Page 19 - Extreme Flexibility; More servers with choice of; Common power slot; Reduces # of spares needed
HP Confidential NDA required Extreme Flexibility Flexible storage • More servers with choice of LFF or SFF drives • Choice of SSD support Common power slot • Reduces # of spares needed • Simplifies Ordering Flexible Smart Array Portfolio • Mix and match cache with batteries for performance and avail...
Page 20 - ProLiant G6:Technology; Prozessor
© 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice ProLiant G6:Technology Prozessor
Page 21 - Nehalem Processor; Higher performance, better power efficiency, more adaptable; QuickPath Architecture; Integrated Memory Controller; Turbo Mode; Dynamic Power Management
HP Confidential NDA required Nehalem Processor Higher performance, better power efficiency, more adaptable QuickPath Architecture Delivers additional performance, bandwidth, and reliability Integrated Memory Controller Each processor now has a dedicated memory controller Turbo Mode Additional proces...
Page 22 - Intel Nehalem Processor Details
HP Confidential NDA required Intel Nehalem Processor Details Power: • 95W, 80W, 60W¹ Process: • 45nm CPU Features: • 2 or 4 cores • 8M on-chip Shared Cache • Simultaneous Multi- Threading capability (SMT) • Intel ® QuickPath Interconnect up to 6.4 GT/s, each direct. per link • Integrated Memory Cont...
Page 23 - Nehalem Turbo Mode; Description; CPU operates at higher-than-stated frequency when; Methods; Example
HP Confidential NDA required Nehalem Turbo Mode Frequency (F) Core Core Core Core Description CPU operates at higher-than-stated frequency when operating below power and thermal design points 3 Methods of Control 1. Off: CPU operates only at rated frequency 2. Automatic: OS requests higher perf stat...
Page 24 - Nehalem-EP Turbo Mode Frequencies
HP Confidential NDA required Nehalem-EP Turbo Mode Frequencies 1.86 GHz DC 2.00 GHz 2.13 GHz 2.26 GHz 2.40 GHz 2.53 GHz 2.66 GHz 2.80 GHz 2.93 GHz 3.06 GHz 3.20 GHz 3.33 GHz 3.46 GHz Perf (95W) WS (130W) 4C/3C turbo 1C/2C turbo Base Freq +1 +2 +1 +2 +2 +3 +3 +3 +2 Volume (80W) Value (80W) +2 +2 +2 1...
Page 26 - New DDR-3 Memory Benefits; Lower latency; savings over DDR2; Flexibility; Larger memory footprints; Increased slot counts with G6; Bandwidth doubles
HP Confidential NDA required New DDR-3 Memory Benefits Lower latency • 24GB/sec with DDR-2 • 64GB/sec with DDR-3 25% power savings over DDR2 • Voltage reduced from 1.8V to 1.5V • Thermal temperature sensors allow power down when idle Flexibility • Unbuffered DIMMs • Registered DIMMs Larger memory fo...
Page 27 - Customer choice with DDR-3; Memory Technology Comparison; Dual Rank
HP Confidential NDA required Customer choice with DDR-3 Memory Technology Comparison RDIMMs Greater capacity, ECC w/advanced memory protection UDIMMs Smaller capacity, lower price points, ECC Capacities at launch 2GB, 4GB, 8GB 1GB, 2GB Max. DIMMs/Channel 3 Dual Rank 2 Dual Rank Advanced Memory Prote...
Page 28 - DDR3 memory capacities
HP Confidential NDA required 2 16 April DDR3 memory capacities • RDIMM maximum capacity 144GB (8GB 2Rank) • UDIMM maximum capacity 24GB (2GB 2Rank) 95 Watt processors needed to run 1333MHz. See population rules for additional guidelines.
Page 29 - Hard Drives
ProLiant G6:Technology Smart Array & Hard Drives
Page 30 - New Modular Smart Array Controller; New Modular solutions; Features
HP Confidential NDA required 30 HP Confidential NDA required 256MB New Modular Smart Array Controller Configurations New Modular solutions Common form factor, hardware, and firmware Seamless upgradeability from zero memory to 512 BBWC 4 4 4 4 4 4 4 External Connectors 4 Internal Connectors Supported...
Page 31 - Support Continued; HP SAS Expander Card; Ports Available; Support
HP Confidential NDA required 3 Support Continued • Internal and External Devices – SAS/SATA HDD (internal only) – Tape Drives (internal and external) – DAT 160 SAS – LTO448 – LTO920 – LTO1840 • Servers – ML350 G6 – ML370 G6 – DL380 G6 – DL385 G5p – DL385 G6 – DL580 G5 – DL785 G5 – DL785 G5p • Contro...
Page 32 - Customer Values
HP Confidential NDA required Smart Array Advanced Pack (SAAP) – January 2009 What is SAAP? SAAP is a paradigm shift in how features are received and utilized by the introduction of “silver bullet” features to continue driving SAS, Smart Array value and differentiation . SAAP Release 1 Features - ILP...
Page 34 - New Embedded NICs on ProLiant G6 Servers
HP Confidential NDA required New Embedded NICs on ProLiant G6 Servers G6 Platform Networking Controller HP Model What’s New DL160 DL180 Intel 82576 HP NC362i Dual port, high- performance gigabit connectivity designed for a multi-core and virtualized platform DL360 DL380 Broadcom 5709 HP NC382i Lates...
Page 35 - Onboard
ProLiant G6:Technology Onboard Administrator powered by iLo2
Page 36 - The core of ProLiant manageability; ProLiant Onboard Administrator
HP Confidential NDA required ProLiant Onboard Administrator The core of ProLiant manageability 36 16 April 2009 HP Confidential - need to know required Save hundreds or thousands in travel cost and downtime Enable hands off deployment for one server or hundreds Investigate server health in any situa...
Page 37 - HP Integrated Lights-Out iLO 2; iLO 2 help you manage your ProLiant G6 agentlessly
HP Confidential NDA required 37 HP Integrated Lights-Out iLO 2 • iLO 2 help you manage your ProLiant G6 agentlessly − Status, presence, redundancy − Fan, temperature, power supplies, VRM − Hard Drive presence − Server status − ProLiant F6 Fan Control and DIMM Temperature metrics • iLO 2 can help you...
Page 38 - Simply migrate your existing server to G6; Confidently upgrade, Accelerate deployment; or; Server Migration Pack Universal Edition
HP Confidential NDA required Simply migrate your existing server to G6 No need for from-the-ground-up deployment Automated migration process takes care of driver compatibility Drop or resize partitions during migration Confidently upgrade, Accelerate deployment Minimize cost of transition Drivers OS...
Page 39 - New Features for 100 series G6 servers; as part of server BOM.
HP Confidential NDA required HP ProLiant Easy Set-up CDs - New Features for 100 series G6 servers ProLiant 100 series G6 servers get this capability as each server announces. Ships as part of server BOM. Supported in 2009: • All of the above on DL1xx G6 servers as servers announce. Assisted Installa...
Page 40 - G6 Product Details
Page 46 - HP ProLiant 100 series
HP Confidential NDA required HP ProLiant 100 series DL120 DL180 ML150 Cost… Performance… Density… Expansion… G6 DL160
Page 47 - highly efficient
HP Confidential NDA required HP ProLiant DL160 DL160 G5 DL160 G6 Processor (2) Xeon (Harpertown/Wolfdale) (2) Xeon (Nehalem EP) Memory 8 Sockets, DDR2 667-800MHz FBD 18 Sockets, DDR3 1067/1333 Drive Bays 4 LFF SATA/SAS NHP/HP Up to 4 LFF or 8 SFF SATA/SAS NHP/HP Storage Controller SW RAID embedded w...
Page 51 - HP Confidential – HP Internal Use Only; ProLiant Generation Features
HP Confidential NDA required 5 HP Confidential – HP Internal Use Only ProLiant Generation Features G5 Intel: Front Side Bus architecture; Fully- Buffered (FB) DDR2 DIMMsAMD: NUMA; RDDR-2 DIMMs G6 Intel : Nahalem processors; NUMA; DDR3 memoryAMD: Shanghai, Istanbul processors Low Power DIMM options L...
Page 53 - BL460c Improved Power Efficiency; wa
HP Confidential NDA required 5 HP Confidential – HP Internal Use Only BL460c Improved Power Efficiency BL460c and BL460c G5: 1P Xeon E5450 (3.0GHz, 80W), 2 x 1GB FBDIMM, 1 x 72GB SAS BL460c G6: 1P Nahalem (2.8GHz, 95W), 2 x 1GB DDR3-1333 UDIMMs, 1 x 72GB SAS 0 10 20 70 80 90 Standby Windows Idle BL4...
Page 56 - Transition
© 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Transition G5 -> G6
Page 57 - Transition Roadmap
HP Confidential NDA required Transition Roadmap BESCHREIBUNG LAUNCH INTRO EOL DISC 2. FQ '09 3. FQ '09 4. FQ '09 1. FQ '10 Mär. '09 Apr. '09 Mai '09 Jun. '09 Jul. '09 Aug. '09 Sep. '09 Okt. '09 Nov. '09 Dez. '09 BL460c Server HP BL460c G1 1. Aug. '09 31. Okt. '09 HP BL460c G5 1. Aug. '09 31. Okt. '0...