Honeywell CT410B1017/E1 - User Manual
Honeywell CT410B1017/E1 Thermostat – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – WARNING; CHECK OUT THERMOSTAT; SETTING THERMOSTAT
- Page 3 – TROUBLESHOOTING
- Page 4 – -YEAR LIMITED WARRANTY
INSTALL ATION INSTRUCTIONS
69-1562-02
T410A,B Line Voltage
Electric Heat Thermostats
T410A provides single-line break.
T410B provides double-line break.
Temperature Range: 40°F to 80°F (4°C to 27°C)
Electrical Ratings: 60 Hz noninductive
22A at 120-240 Vac; 19A at 277 Vac
Your Resideo Thermostat
Your new Resideo T410 Electric Heating Thermostat
provides line voltage control of a radiant cable,
electric baseboard, and resistive-rated fan forced
heaters within the ratings listed above.
WARNING
Electric shock hazard
This thermostat is a line voltage control (120
Volts to 277 Volts.) Do not install it if you are
not completely familiar with house wiring. If
handled improperly, there can be risk of a 120
Volt to 277 Volt electric shock hazard, which
may cause serious injury or death.
MERCURY NOTICE
If this control is replacing a control that
contains mercury in a sealed tube, do not
place you old control in the trash. Dispose of
properly.
Contact you local waste management
authority for instruction regarding recycling
and the proper disposal of a old control.
1 PREPARATION
Proper installation of your Resideo thermostat will
occur if you follow these instructions STEP-
BYSTEP. It is recommended that as you read,
understand and complete each step, you check it
off with pencil or pen.
Check thermostat suitability for your home system
by reviewing the ratings listed on this page.
Make certain that your heating system is working,
especially if it has been inoperative for a length of
time. If the system does not work, contact your
local electrician for assistance.
Carefully unpack your new thermostat. To avoid
damage to the sensing element, do NOT remove
the thermostat cover until wiring has been
completed.
Save packages of screws, instructions, receipt and
proof-of-purchase.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
T410A,B LINE VOLTAGE ELECTRIC HEAT THERMOSTATS 69-1562—02 2 2 REMOVE OLD THERMOSTAT WARNING Electric shock hazard Begin by turning off power to the heating circuit at the main service panel. Remove cover of old thermostat. Cover normally snaps off when pulled firmly from the bottom. If it resists,...
T410A,B LINE VOLTAGE ELECTRIC HEAT THERMOSTATS 3 69-1562—02 6 TROUBLESHOOTING Your Resideo thermostat requires little or no attention. Most problems can generally be traced to the following: Table 1. Troubleshooting. Symptom Checkout Action No heat. Make sure power is on at main service panel. Turn ...
T410A,B LINE VOLTAGE ELECTRIC HEAT THERMOSTATS This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved. www.resideo.com Resid...