INSTALL ATION INSTRUCTIONS

69-1562-02

T410A,B Line Voltage
Electric Heat Thermostats

T410A provides single-line break.

T410B provides double-line break.

Temperature Range: 40°F to 80°F (4°C to 27°C)

Electrical Ratings: 60 Hz noninductive

22A at 120-240 Vac; 19A at 277 Vac

Your Resideo Thermostat

Your new Resideo T410 Electric Heating Thermostat
provides line voltage control of a radiant cable,
electric baseboard, and resistive-rated fan forced
heaters within the ratings listed above.

WARNING

Electric shock hazard

This thermostat is a line voltage control (120
Volts to 277 Volts.) Do not install it if you are
not completely familiar with house wiring. If
handled improperly, there can be risk of a 120
Volt to 277 Volt electric shock hazard, which
may cause serious injury or death.

MERCURY NOTICE

If this control is replacing a control that
contains mercury in a sealed tube, do not
place you old control in the trash. Dispose of
properly.

Contact you local waste management
authority for instruction regarding recycling
and the proper disposal of a old control.

1 PREPARATION

Proper installation of your Resideo thermostat will
occur if you follow these instructions STEP-
BYSTEP. It is recommended that as you read,
understand and complete each step, you check it
off with pencil or pen.

Check thermostat suitability for your home system
by reviewing the ratings listed on this page.

Make certain that your heating system is working,
especially if it has been inoperative for a length of
time. If the system does not work, contact your
local electrician for assistance.

Carefully unpack your new thermostat. To avoid
damage to the sensing element, do NOT remove
the thermostat cover until wiring has been
completed.

Save packages of screws, instructions, receipt and
proof-of-purchase.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WARNING; CHECK OUT THERMOSTAT; SETTING THERMOSTAT

T410A,B LINE VOLTAGE ELECTRIC HEAT THERMOSTATS 69-1562—02 2 2 REMOVE OLD THERMOSTAT WARNING Electric shock hazard Begin by turning off power to the heating circuit at the main service panel.  Remove cover of old thermostat. Cover normally snaps off when pulled firmly from the bottom. If it resists,...

Page 3 - TROUBLESHOOTING

T410A,B LINE VOLTAGE ELECTRIC HEAT THERMOSTATS 3 69-1562—02 6 TROUBLESHOOTING Your Resideo thermostat requires little or no attention. Most problems can generally be traced to the following: Table 1. Troubleshooting. Symptom Checkout Action No heat. Make sure power is on at main service panel. Turn ...

Page 4 - -YEAR LIMITED WARRANTY

T410A,B LINE VOLTAGE ELECTRIC HEAT THERMOSTATS This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved. www.resideo.com Resid...