Page 2 - QuickSpecs; HP ProLiant ML330 Generation 6; Overview
One Quad-Core/Dual Core Intel® Xeon® W3500 processorsIntel® 5500 chipset Memory : 18 DIMM slotsUp to 192GB, using PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when fullypopulated at 3 DIMMs per Channel in 18 slots.Up to 48GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operatin...
Page 4 - Processor; depend on the quantity and type of DIMMs installed.; Cache Memory; Standard Features
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. Processor One of the followingdepending on Model Six-Core Processors Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W,...
Page 7 - Graphics; Integrated ATI RN50, 64MB video standard; Form Factor; the options section in this QuickSpecs:
Graphics Integrated ATI RN50, 64MB video standard 16 bit color: maximum resolution of 1600 x 120032 bit color: maximum resolution of 1280 x 1024 NOTE: Maximum resolution available via HP Integrated Lights-Out 2 (iLO 2) remote console is 1280 x 1024. Form Factor Tower (5U) NOTE: Rack mounting availab...
Page 8 - System Management
requiring either a Linux-based or a Windows-based central managementserver: HP Insight Control for Linux, and HP Insight Control. See www.hp.com/go/insightcontrol HP Insight Control includes one year of 24 x 7 HP Software TechnicalSupport and Update Service ensuring rapid access to HP support staffa...
Page 9 - Security; Trusted Platform Module option kit; Power Supply; The 750W power supply requires RPS Enablement kit.
Security Power-on passwordSetup passwordSerial interface controlPower switch securityFront bezel/side access panel LockPadlock and Kensington lock availableKeyboard/Mouse/USB port lock Security - TrustedPlatform Module Trusted Platform Module option kit The TPM (Trusted Platform Module) is a microco...
Page 10 - System Fans; packed in processor kit.
System Fans 3 fans ship standard, 4 fans total supported (optional (1) redundant fan) NOTE: Does not include power supply or processor heat sink fans. Processor heat sink fans packed in processor kit. NOTE: There are two fans packed in the Redundant Fan Kit, only 1 is required for system redundant f...
Page 12 - Models
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. HP ML330 G6 EntryModel Quad-Core ModelsHP ML330T06 E5504LFF Non Hot Plug 504055-xx1 Processor (1) Intel® Xeon® Processor E5504 (...
Page 14 - start with a CTO Chassis.; HP Models; Configuration Information - Factory Integrated Models
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local salesrepresentative for information on CTO product offerings and requirements. NOTE: ...
Page 15 - HP Memory; configurator; HP Drive Cage Options Non-Hot Plug HDD Model; HP SATA 5U G6 Module FIO Kit; Hot Plug HDD Model; HP Hot Plug HDD Drive Cage Kit; HP Hard Drives
Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800)ML330G6 FIO Kit 535580-L21 Intel® Xeon® Processor W3505 (2.53 GHz, 4MB L3 Cache, 130W, DDR3-1066)ML330G6 FIO Kit 573362-L21 Intel® Xeon® Processor W3503 (2.40 GHz, 4MB L3 Cache, 130W, DDR3-1066)ML330G6 FIO Kit 573363-L21 NOTE: Xeon ...
Page 16 - SAS non-hot plug drives require the Non-Hot Plug Internal SAS/SATA 4; HP Power supplies; or
HP 450GB 6G SAS 15K LFF (3.5-inch) Non-hot Plug Dual Port ENT 3y WtyHard Drive 516826-B21 HP 450GB 3G SAS 15K LFF (3.5-inch) Non-hot Plug Dual Port ENT 3y WtyHard Drive 454234-B21 HP 300GB 6G SAS 15K LFF (3.5-inch) Non-hot Plug Dual Port ENT 3y WtyHard Drive 516824-B21 HP 300GB 3G SAS 15K LFF (3.5-i...
Page 17 - Step 3: Choose Additional Factory Integratable Options; HP Storage Controllers; HP P410/ZM FIO Smart Array Controller; Optional Upgrades; Battery Kit upgrade; HP Insight Software; Step 4: Choose Additional Options for Factory Integration
Step 3: Choose Additional Factory Integratable Options HP Storage Controllers HP P212 /256 FIO SA Cntrlr w/Battery 491191-B21 HP P410/ZM FIO Smart Array Controller 462860-B21 HP P410/256 FIO SA Cntrlr w/Battery 491195-B21 HP P411/256MB BBWC Smart Array Controller FIO Kit NOTE: SAS Controller support...
Page 18 - HP Processors; When two (2) Xeon E5500 processors are installed, the system QPI will; Core Options
NOTE: Some options may not be factory configurable. Please contact your local sales representative for additional information. HP Processors Six-Core Processors Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333,HT, Turbo 2/2/3/3/4/4) ML330G6 Processor Kit 603978-B21 Quad-Core Pro...
Page 19 - HP Optical Drives; HP Half-Height SATA DVD-ROM Optical Drive; HP Drive Cage Options; HP 5U Hot Plug HDD Drive Cage Kit
HP Memory Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21 HP 4GB 1Rx4 PC3-10600R-9 Kit 593339-B21 HP 4GB 1Rx4 PC3L-10600R-9 Kit NOTE: Low Voltage DIMMs can only be used with Intel® Xeon® processor 560...
Page 21 - A minimum of 2 GB of server memory is required per each NC522SFP
HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Entry 1y Wty HardDrive 458947-B21 NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html (Worldwide) SATA Hot Plug 3.5" Midline (MDL) Sol...
Page 22 - HP Power Supplies; HP Cooling Options; HP 5U G6 Redundant fan kit
HP Power Supplies NOTE: It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your need. The HP Power Advisor is locatedat: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor CAUTION: Optional Power Supplies used for Red...
Page 23 - linux; Additional Options
HP Insight Software HP Insight Control HP Insight Control, Single-Server License including 1 year of 24x7 TechnicalSupport and Updates 452148-B22 HP Insight Control suite, No Media, Electronic License including 1 year of 24x7Technical Support and Updates T9074BAE HP Insight Control, Electronic Licen...
Page 26 - For the complete range of StorageWorks tape drives, autoloaders,; Rack-Mount Tape Solutions; Requires HP 1U Tape Autoloader Rack Kit (AH166A) for rack
Backup & RecoverySoftware HP Data Protector Express HP Data Protector Express 4.0 SP1 Backup Server BB117BA HP Data Protector Express 4.0 SP1 for Microsoft Small Business Server BB118BA HP Data Protector Express Backup Server 4.0 SP1Upgrade from Data ProtectorExpress Single Server Edition BB117B...
Page 28 - Please see the QuickSpecs for additional information:
HP UninterruptiblePower Systems HP Tower UPS HP T1000 G3 UPS Models HP T1000 G3 UPS, NA AF448A HP T1000 G3 UPS, INTL AF449A HP T1000J UPS, Japan AF457A HP T1500 G3 UPS Models HP T1500 G3 UPS, NA AF450A HP T1500 G3 UPS, INTL AF451A HP T1500J UPS, Japan AF458A NOTE: Please see the QuickSpecs for addit...
Page 29 - Rack Kit; HP Tower to Rack Conversion Tray, Universal Kit; HP VMware Getting; for installation instructions.; HP Care Pack Services Hardware Services On-site Service; Next Day Service, 3 Year; Other Services
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13474_div/13474_div.html (Worldwide) Rack Kit HP Tower to Rack Conversion Tray, Universal Kit 417705-B21 HP USB and SDOptions HP USB 2-Button Optical Scroll Mouse (C...
Page 30 - Memory
NOTE: Memory configurations listed do not apply to "Factory Integrated Models". DDR3 memory population guidelines For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator Some DIMM installation guideli...
Page 31 - Standard memory configuration (1 CPU model); population order
PC3-10600 DIMMs have a maximum speed of 1333MHz. PC3-8500 DIMMs have a maximum speed of 1066MHzMixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilitiesIf you do mix DIMM speeds, the memory bus will default to the minimum clock rate of all DIMMs in the...
Page 32 - Standard memory plus optional memory (1 CPU model); UDIMM maximum configuration (1 CPU model)
Standard memory plus optional memory (1 CPU model) 60GB, consisting of two (2) 2GB RDIMMs plus seven (7) 8GB RDIMMs 2x 2GB dual-rank PC3-10600 RDIMMs7x 8GB dual-rank PC3-8500 RDIMMs CPU1 CPU2 slot # population order slot # population order Chnl 1 1 G; 8GB DIMM 1 G; empty Chnl 1 2 D; 8GB DIMM 2 D; em...
Page 33 - UDIMM maximum configuration (2 CPU model)
CPU1 CPU2 slot # population order slot # population order Chnl 1 1 G; empty 1 G; empty Chnl 1 2 D; 4GB DIMM 2 D; empty 3 A; 4GB DIMM 3 A; empty Chnl 2 4 H; empty 4 H; empty Chnl 2 5 E; 4GB DIMM 5 E; empty 6 B; 4GB DIMM 6 B; empty Chnl 3 7 I; empty 7 I; empty Chnl 3 8 F; 4GB DIMM 8 F; empty 9 C; 4GB ...
Page 34 - Capacity references are rounded to the common Gigabyte values.; Following are memory options available from HP:; Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600
NOTE: Capacity references are rounded to the common Gigabyte values. 1GB = 1024MB2GB = 2048MB4GB = 4096MB8GB = 8192MB Following are memory options available from HP: HP Memory Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-85...
Page 35 - Drive Support; the HBA or Controller technical specifications for details.; Storage
A Optical Drive B,C Removable Media Bays- 1 full-height drive or 2 half-height drives 1-4 4 x 3.5" (LFF) Hot plug or Non hot-plug SATA/SAShard drive bays (Standard) 5-8 4 x 3.5" (LFF) Hot plug SATA/SAS hard drive bays(Optional) Drive Support Quantity Supported Position Supported Controller R...
Page 39 - Please check the full compatibility information at:
HP StorageWorks SASTape Autoloaders andLibraries, External 1/8 G2 AutoloaderMSL2024MSL4048MSL8096 External HP SC44Ge SAS Host Bus Adapter 416096-B21 NOTE: Please check the full compatibility information at: http://www.hp.com/go/connect HP StorageWorks FibreChannel Tape Libraries MSL2024MSL4048MSL809...
Page 40 - Power Specifications
460W PSU Part Number 500447-B21 Operational Input Voltage Range(Vrms) 90 to 135 Frequency Range (Nominal) (Hz) 47 to 66 Hz Nominal Input Voltage (Vrms) 100 115 208 220 230 240 Max Rated Output Wattage Rating 460 460 460 460 460 460 Nominal Input Current (A rms) 10 10 5 5 5 5 Max Rated Input Wattage ...
Page 41 - See Power Supply Specifications; Technical Specifications
System Unit Tower Dimensions (H x W x D)(W/O foot stand) 7.87 x 16.81 x 24.13 in (200 x 427 x 613 mm) Tower Weight (approximate) Maximum:(All hard drives, powersupplies and processorsinstalled) 30 kg Minimum:(One hard drive, powersupply and processorinstalled) 16 Kg Input Requirements (per power sup...
Page 42 - Altitude; Operating; Acoustic Noise; The listed sound levels apply to; FCC Rating; Class B; Normative Standards; Product conformance to cited product specifications is based on
Altitude Operating 10,000 ft (3000m). Maximum allowablealtitude change rate is 1°C per 300m. Non-Operating 30,000 ft (9144m). Maximum allowablealtitude change rate is 1°C per 300m. Acoustic Noise Listed are the declared A-Weighted sound power levels (LWAd) anddeclared average bystander position A-We...
Page 43 - * Maximum drive dimension
HP Smart Array B110iSATA RAID Controller(RAID 0,1,10) Dimensions N/A (embedded) Disk Drive andEnclosure ProtocolSupportArchitecture 3.0 Gbps SATA 64-bit SAS Connectors 4 internal x1 SATA connectors Software UpgradeableFirmware Yes. HP Smart Array hot plug Advanced Pack No Media 1-Serverlicense inclu...
Page 44 - or contact your nearest HP
Embedded NC326i PCIExpress Dual PortGigabit Server Adapter Network Interface 10Base-T/100Base-TX/1000Base-TX Compatibility IEEE 802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX Data Transfer Method PCI Express, four lanes (x4) Controller BCM5715C Network Transfer Rate 10Base-T (Half-Dup...