Page 4 - TABLE OF CONTENTS
4 TABLE OF CONTENTS TABLE OF CONTENTS ...................................................................................................................................................................4 1 GENERAL INFORMATION ..............................................................................
Page 6 - ENVIRONMENT: Operating Temperature Range:
6 1 GENERAL INFORMATION The DS73 and the DS73TP peripheral communications module supports remote access to TCP/IP Ethernet networksby using the DS-Series Data Switch with a modem module installed. Remote users can dial into the DS-Series unitand connect to network hosts from anywhere at anytime. Bot...
Page 7 - CABLING; OPERATION
7 3 CABLING CAUTION: Power should be turned off when cables are being installed. 3.1 10BASE2 (COAX) CONNECTION The 10BASE2 port of the DS73 peripheral module connects to any BNC connector on the network cable. BayTechprovides a T-connector for this purpose. The DS73TP has a 10BASE-T connector only. ...
Page 8 - The factory default Password is BTA.
8 4.1.4 GATEWAY The Gateway is the address of a router for connection to other networks. The Gateway address consists of fourbytes with each byte ranging from 0 to 255 decimal. The factory default Gateway address is 0.0.0.0. 4.1.5 PRIMARY DNS The Primary DNS (domain name server) IP address to be pro...
Page 9 - MODULE IP ADDRESS
9 Bay Technical Associates Port Select Code: $BTAttention Character: ; DS73 (2,1).................... 1 Device A (3,1).................... 2 Device B (3,2).................... 3 Device C (3,3).................... 4 Device D (3,4).................... 5 Configure ............................... C I/O ...
Page 10 - SUBNET MASK; GATEWAY; Primary DNS
10 Type “1” (Module IP Address), at the end of the main configuration menu and you can program the IP address. TheDS73 will respond with: Enter Module IP address in dotted decimal form: Enter the desired Module IP address as a series of four numbers separated by periods (e.g., 197.3.14.9) followed b...
Page 11 - PASSWORD; UNIT RESET; Attention Character(default; EXIT
11 Enter Primary DNS address in dotted decimal form: Enter the desired Primary DNS address as a series of four numbers separated by periods (e.g., 0.0.0.0.) followed by Carriage Return . 8.6 PASSWORD By responding to the Enter selection: message at the end of the main configuration menu with " 5...
Page 12 - LOGOUT
12 By responding to the Enter Request : message in the DS73 Status & Diagnostics Menu with “X” (Exit ), you will exit the DS73 Status & Diagnostics Menu. The DS73 peripheral module will respond with the following: > X 5.1.6 LOGOUT By responding to the Enter Request : message in the DS73 M...
Page 13 - GETTING STARTED; MAINTENANCE
13 9 GETTING STARTED Before the DS73 or DS73TP and the DAC can be used, there are a few parameters which must be configured by theuser. First time power-up: When the DS73 or DS73TP is first powered up, it will cycle through its diagnostics until it findsthat it has not been programmed with an IP add...
Page 14 - RETURNS TO THE FACTORY; REPACKAGING FOR SHIPPING; TECHNICAL SUPPORT
14 11 RETURNS TO THE FACTORY If you find it necessary to return any component of the DS-Seriesunit to the factory for warranty work or factory -setchanges, follow the procedure listed under Section 12 for repackaging. Before you ship your unit, please call BayTech to get a Return Authorization numbe...
Page 16 - DS73/DS73TP MECHANICAL LAYOUT
Page 17 - INDEX
17 INDEX —1— 10BASE2, 610BASE-T , 6 —8— 802.3 compliant, 6 —A— Active User, 14A p p l i c a t i o n s e n g i n e e r s , 23A R P , 6ASCII character string, 10, 16A t t e n t i o n C h a r a c t e r, 10A u t h o r i z e d s e r v i c e a g e n c y , 24 —B— Bus Data Flo , 19 —C— C a s e s e n s i t i...