Contents 3 Contents About this guide ........................................................................................................................... 7 Rack options installation guide ............................................................................................................
About this guide 7 About this guide Rack options installation guide This installation guide includes the instructions for installing rack option kits that are compatible with the HP 10000 G2 Series Rack. For more information, see the HP 10000 G2 Series Rack User Guide on the HP website
Rack options 9 Rack options Ordering rack options HP provides several rack option kits to complement or complete your rack solution. The following list is a sample of the many rack option kits available. For information about ordering rack option kits, see the HP website
100 Kilo Sliding Shelf kit 11 100 Kilo Sliding Shelf kit About this device The HP 100 Kilo Sliding Shelf kit enables you to install a sliding shelf in your rack mount system for placement and easy access to various components. This option occupies 2Us of rack space. Kit contents Item Quantity Shelf ...
100 Kilo Sliding Shelf kit 12 3. Extend the inner slides of the sliding rail until the screw holes on the sliding rail and the left rail with fixed brackets are aligned. Gently push down on the sliding rail to lock it into place. 4. Secure the rails together with two M4 x 12 flat HD screws and M4 ex...
100 Kilo Sliding Shelf kit 14 3. Secure the front of the left sliding shelf rail assembly to the front of the rack frame with two M6 x 12 pan HD screws and M6 external washers. 4. Repeat steps 2 and 3 to install the right sliding shelf rail assembly. Installing the sliding shelf 1. Move the sliding ...
100 Kilo Sliding Shelf kit 16 7. Secure the opposite end of the cable management arm to the rack using two M6 x 12 pan HD screws and M6 external washers. Installation is complete. Using the 100 Kilo Sliding Shelf Use the handle on the front of the sliding shelf to slide it in and out of the rack. Wh...
Airflow Optimization kit 17 Airflow Optimization kit About this device The HP Airflow Optimization kit enables you to install foam rail gaskets in your HP 10000 G2 Series 22U, 36U, 42U, and 47U 600-mm (24-in) wide racks and in to 42U 800-mm (31-in) wide racks to improve separation between hot and co...
Airflow Optimization kit 18 3. Insert the foam rail gasket into the space between the 19-in mounting rails and the vertical frame on both sides of the rack, with the closed cell side of the foam rail gasket facing the front of the rack. 4. Gently push the foam rail gasket into the space until it is ...
Airflow Optimization kit 20 5. (Optional) See the HP Baying Rack Option Kit for specific information on baying racks. Installing the floor gasket 1. Depending on the size of your rack, cut the floor gasket at the perforation to reduce the length from 800-mm (31 in) to 600-mm (24 in).
Ballast kit 22 Ballast kit About this device The HP Ballast kit provides additional stability with single-rack installations. Kit contents Item Quantity Ballast assembly 2 M6 screws 10 Cage nuts 10 Extra hardware might be included for your convenience. Required tools The following tools are required...
Baying kit 25 Baying kit About this device The HP Baying kit enables you to connect multiple racks of the same series (HP 10000 and 10000 G2 Series Racks), height, and depth. For example, two HP 10622 Racks can be bayed together, as well as two HP 10842 Racks. Kit contents Item Quantity 24-inch bayi...
Cable Management Bracket kit 28 Cable Management Bracket kit About this device The HP Cable Management Bracket kit assists with cable management and is designed for use with all HP racks. Kit contents Item Quantity 1U cable management bracket 1 2U cable management bracket 1 Cable management D-ring b...
Cable Management Bracket kit 29 Installing the 1U cable management bracket 1. Insert one 1/4 turn plastic latch on either side of the 1U cable management bracket. 2. Align the 1U cable management bracket to the screw holes in the desired location of the rack (1). 3. Turn the 1/4 turn plastic latch o...
Cable Management Bracket kit 30 Installing the 2U cable management bracket 1. Insert two 1/4 turn plastic latches on either side of the 2U cable management bracket. 2. Align the 2U cable management bracket to the screw holes in the desired location of the rack (1). 3. Turn the two 1/4 turn plastic l...
Cable Management Bracket kit 31 1. Place a cable management D-ring bracket clip (1) on a cable management D-ring bracket clamp (2). 2. Install the cable management D-ring bracket in a front mount (" Front mount " on page 31 ). 3. Install the cable management D-ring bracket in a side mount (&...
Cable Management Bracket kit 32 3. Using a T-25 Torx driver, insert one M6 x 16-mm Torx screw to secure the cable management D-ring bracket to the rack (2). Side mount 1. Align the cable management D-ring bracket with the screw hole in the desired location on the side of your rack (1). 2. Using a T-...
Cable Management Bracket kit 34 Installing the hook-and-loop cabling straps Attach the clip to the rack in any of the following positions, then route and secure your cables with the hook-and-loop cabling straps.
Cable Management Tray kit 36 Cable Management Tray kit About this device The HP Cable Management Tray kit enables you to attach cable management trays to the top of HP racks to improve cable management. Kit contents Depending on which kit you order, this kit includes the following items: Item Quanti...
Cable Management Tray kit 37 Installing the cable management tray 1. Attach the wire for the trough to the cable management tray. 2. Remove the two screws from the rack top.
Cable Management Tray kit 39 5. Hook and slide the cover into place. Installing the cable management inner and outer trays 1. Attach the cable management outer tray to the cable management tray.
Cable Management Tray kit 41 4. Route the cables through the cable management tray. Ground bonding stud location
Fan (110V/220V) kit 42 Fan (110V/220V) kit About this device The HP Fan (110V/220V) kit enhances the natural convection cooling by increasing rack airflow. Kit contents Item Quantity Fan assembly 1 Power cord 2 Cable fastener 4 This kit might contain extra hardware for your convenience. Required too...
Filler Panel kit 45 Filler Panel kit About this device The HP Filler Panel kit enables you to cover open areas of the rack to better control airflow. Kit contents Item Quantity 1U Filler panels —or— 1U Filler panels 10 100 This kit might contain extra hardware for your convenience. Required tools No...
Front Door kit 46 Front Door kit About this device The HP Front Door kit enables you to add a front door to your HP 10000 G2 Series rack. You can also install this option kit on HP 10000 series racks of the same size. Kit contents Item Quantity Front door 1 Keys 2 Hinge brackets 2 Lock catches 2 Thi...
Front Door kit 47 Installing the hinge brackets and lock catches The following tables indicate where the hinge brackets and lock catches are to be mounted in a 36U or 42U front door installation. The distance is measured from the bottom of the rack to an indicated hinge bracket or lock catch fasteni...
Front Door kit 48 Installing the front door 1. Slide the bottom door hinge onto the hinge bracket on the rack frame. 2. Lift the top hinge pin up, and slide the upper door hinge into place. 3. Release the top hinge pin to secure the front door to the rack. 4. Close the front door. Installation is co...
Ground Bonding kit 49 Ground Bonding kit About this device The HP Ground Bonding kit reduces the electromagnetic emissions outside the rack. These emissions are produced during normal operation of the electronic components within the rack. Typically, rack-mounted equipment must meet class A emission...
Ground Bonding kit 55 From the rack to a building facility , contact your building supervisor for more information. The following figure illustrates parts for this step. Reference Item 1 48.26-cm (19-in) mounting rail (the mounting hole is located at the top or bottom of the rail) 2 M8 hex nut 3 M8 ...
Ground Bonding kit 67 Installing the ground bonding rack option kit on HP 10000 Series Rack side panels From the system chassis rail to the side panel: 1. Connect a 36.83-cm (14.5-in) and a 15.24-cm (6-in) grounding strap with connectors together. 2. Insert a T-25 Torx screw through the end of the 3...
Heavy Duty Stabilizer kit 69 Heavy Duty Stabilizer kit About this device The HP Heavy Duty Stabilizer kit provides stability and support and prevents possible tipping when you install, remove, or access equipment within the rack. If you have a stand-alone rack with a single rack-mountable component ...
Hook-and-Loop Cabling Strap Clip kit 73 Installing the hook-and-loop cabling strap clips Route and secure your cables with the hook-and-loop cabling strap clips.
Light kit 76 Light kit About this device The HP Light kit enables you to add a light to the rack. Kit contents Item Quantity 110V/220V light assembly 1 Light cover 1 F14W/133-T8 fluorescent lamp 1 Power cord (10 ft), C13-C14 1 Mounting screws 2 This kit might contain extra hardware for your convenie...
Light kit 79 Operating the 110V/220V Light Item Description Status 1 On Turns on the light. 2 Off Turns off the light. 3 Standby mode Turns on the light when the rack door is open, and turns off the light when the rack door is closed. Connecting the power cord to the 110V/220V light Connecting devic...
Light kit 81 F14W/133-T8 fluorescent lamp specifications Electrical data* Nominal value Minimum Maximum Frequency 50 Hz — — Lamp nominal wattage 14 W — — Lamp rated wattage • Single operation • Series operation 14.0 W 30 W 12.8 W — 15.2 W — Lamp operating voltage 38 V 28V 48 V Lamp current • Single ...
Light kit 82 Color No Luminous Flux* Nominal Value CRI Color Temp ILCOS-Code Special colors • Activa • Gro-lux 172 gro 600 lm n/a 1A group n/a 6500 K n/a FD-14/65/1A-E-G13-26/360 Not for general lighting purposes *At 50-Hz operation, lamp aged for 100 h. Material disposal This HP product contains th...
Mini Stabilizer kit 83 Mini Stabilizer kit About this device The HP Mini Stabilizer kit provides stability and support and prevents possible tipping when you install, remove, or access equipment within the rack. Kit contents Item Quantity 600-mm (23.62-in) Front stabilizer mount —or— 800-mm (31.50-i...
Rack Air Duct kit 86 Rack Air Duct kit About this kit The HP 10000 G2 Rack Air Duct kit removes warm air from the rack by channeling the warm air into the data center ceiling return air plenum. The air duct sits on top of the rack, directly joined to the ceiling plenum, preventing the warm air from ...
Rack Air Duct kit 88 Installation video HP recommends watching the HP 10000 G2 Rack Air Duct Installation video. The video provides a demonstration of installation strategies and techniques that might be helpful while installing the air duct. To access the video: 1. Go to the HP website
Rack Air Duct kit 89 3. Using a T-30 Torx screwdriver, remove the M6 flathead screw securing each hinge bracket to the rack (1), and then remove all of the hinge brackets from the rack (2). Retain the hinge brackets and screws for reinstallation. 4. Using a T-25 Torx driver, remove the upper and low...
Rack Air Duct kit 90 2. Remove the perforated top plate of the rack (2). 3. Align the solid plate with the top of the rack (1). 4. Using a T-30 Torx screwdriver, insert and tighten two of the four M-12 bolts (from step 1) into the two corner holes at the front of rack (2). Installing the solid rack ...
Rack Air Duct kit 91 3. Insert the right side plate into the rack, overlapping the left side plate, and set it on the lip of the rack frame (3). 4. Using a T-25 Torx screwdriver, insert and tighten one M5.5 self-tapping screw at the rear, right corner and one M5.5 self-tapping screw at the front, ri...
Rack Air Duct kit 93 Installing the floor gasket 1. Cut the floor gasket at the perforation to reduce the length from 800-mm (31-in) to 600-mm (24-in). 2. Remove the protective tape from the bottom edge of the floor gasket, and then apply it to the bottom of the rack with the adhesive strip facing t...
Rack Air Duct kit 95 4. Using a T-25 Torx driver, remove the upper and lower rear door lock catches by removing the two screws from each of the upper and lower rear door lock catches. Retain the door lock catches and screws for reinstallation. NOTE: Install the solid rear rack doors after you have i...
Rack Air Duct kit 97 b. Using a T-25 Torx driver, insert and tighten four M6 machine screws into each corner hole (3). Installing the solid rear doors 1. Using a T-25 Torx driver, insert and tighten two screws into each of the upper and lower rear door lock catches. 2. Install the hinges brackets. a...
Rack Air Duct kit 101 6. Apply the foam gasketing to the top of the upper duct by peeling the adhesive backing and aligning the gasketing with the top edges of the upper duct. Installing the kit assembly WARNING: The rack air duct weighs approximately 22.5 kg (50 lb). To reduce the risk of personal ...
Rack Air Duct kit 102 5. Using a T-30 Torx screwdriver, insert and tighten two M-12 bolts (from step 1) through the holes of the air duct assembly and into the two rear holes of the rack (3). Adjusting the kit After you have installed the air duct to the top of your rack: 1. Loosen both draw-latch s...
Rack Air Duct kit 103 b. Using an electric drill, drill one 2.38-mm (3/32-in) hole through the lower duct, in the location you marked. c. Insert one M3.5 self-drilling screw through the holes in both the upper and lower ducts (2). Baying options You can order the HP Baying Rack Option Kit to bay you...
Rear Extension kit 105 Rear Extension kit About this device The HP Rear Extension kit enables you to add 200-mm (7.87-in) of depth to the rear of the HP 10000 Series and HP 10000 G2 Series racks. The HP Rear Extension kit only fits the 600-mm (23.62-inch) wide (42U and 47U) rack models. Kit contents...
Rear Extension kit 109 4. Insert the filler panels into the side and top assemblies. Installing the rear doors 1. Using a T-25 Torx driver, insert and tighten two screws into each of the upper and lower rear door lock catches. 2. Install the hinges brackets. a. Align the hinge brackets that you remo...
Rear Extension kit 110 b. Using a T-30 Torx driver, insert and tighten one M6 flathead screw to secure each hinge bracket to the rear extension assembly (2). 3. Lift the rear doors, aligning them with the hinge brackets on the rear extension assembly (1). 4. Push down the hinge pins, and then insert...
Server/Utility Shelf kit 112 Server/Utility Shelf kit About this device The HP Server/Utility Shelf kit enables you to install a convenient shelf in your rack-mount system. This kit can be used with all HP racks. Kit contents Item Quantity Server/Utility shelf 1 Cage nut 2 M6 screw 2 Quick-release t...
Side Panel kit 116 Side Panel kit About this device The HP Side Panel kit enables you to attach side panels to HP 10000 G2 Series Racks. Kit contents Item Quantity Top side panel 2 Middle side panel 2 Bottom side panel 2 Key 2 This kit might contain extra hardware for your convenience. Required tool...
Side Panel kit 117 Installing the side panels 1. Install the top and bottom side panel by sliding the brackets on the side panel behind the tabs on the rack frame.
Tie-Down kit 119 Tie-Down kit About this device The HP 10000 G2 Series Rack Tie-down Kit enables you to secure HP 10000 G2 Series Racks to the floor. This kit is for all 10000 G2 Series Racks except for Rack SKUs AF092A and AF094A. A separate tie-down kit is used exclusively for the 1200 full frame ...
Tie-Down kit 121 Securing the rack to the floor The following illustration indicates where to drill the holes to secure the rack to the floor. The distances are measured from the holes on the tie-downs. Have your building structural engineer drill the holes. After your holes have been drilled, inser...
Tie-Down kit 123 Securing the 1200 mm full frame rack to the floor The following illustration indicates where to drill the holes to secure the 1200 mm full frame rack to the floor. The distances are measured from the holes on the tie-downs. Have your building structural engineer drill the holes. The...
Vertical PDU Mounting kit 124 Vertical PDU Mounting kit About this device The HP Vertical PDU Mounting kit allows HP PDU vertical models to be mounted in HP 10000 G2 Series Racks and in the HP V142 Rack. Kit contents Item Quantity Top bracket 1 Bottom bracket 1 Phillips self tapping screw 4 8-32 Tor...
Electrostatic discharge 126 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boa...
Support and other resources 127 Support and other resources Before you contact HP Be sure to have the following information available before you call HP: • Active Health System log (HP ProLiant Gen8 or later products) Download and have available an Active Health System log for 3 days before the fail...
Acronyms and abbreviations 128 Acronyms and abbreviations KVM keyboard, video, and mouse PDU power distribution unit RKM rackmount keyboard monitor TMRA recommended ambient operating temperature UPS uninterruptible power system
Documentation feedback 129 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback
HP Manuals
-
HP CM1312 MFP
Manual
-
HP DV2700
Manual
-
HP 203A
Manual
-
HP 13-2000
Manual
-
HP 1320NW
Manual
-
HP D4360
Manual
-
HP W19Q
Manual
-
HP FC2143
Manual
- HP ZV6000 Manual
-
HP 7500
Manual
-
HP C4591A
Manual
-
HP E4411B
Manual
-
HP N6310
Manual
- HP nx7000 Manual
-
HP DL120
Manual
- HP w1707 Manual
-
HP CV136A#B1H
Manual
-
HP X585z
Manual
-
HP 686714-S01
Manual
- HP 1200 series Manual