Contents Customer self repair ............................................................................................................................... 1 Parts only warranty service ...................................................................................................................
Customer self repair 1 Customer self repair HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service providers or service partners) identif...
Customer self repair 3 Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Re...
Customer self repair 4 Customer self repair HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der Diagnose feststellt, dass das Produkt mithi...
Customer self repair 5 Reparaciones del propio cliente Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectu...
Customer self repair 7 Reparo feito pelo cliente Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedor...
Illustrated parts catalog 12 Illustrated parts catalog Mechanical components / 2 or 4 3.5” hot-plug HDD model Table 1 Mechanical Components Spare Parts List / 2 or 4 3.5” HDD Hot-plug Model Item Description Spare Part Number Customer Self Repair 1 Air baffle 511806-001 Mandatory 1 2 Power supply cag...
Illustrated parts catalog 13 Mechanical components / 4 3.5” HDD non-hot- plug model Table 2 Mechanical Components Spare Parts List / 4 3.5” HDD Non-hot-plug Model Item Description Spare Part Number Customer Self Repair 1 Air baffle 511806-001 Mandatory 1 2 Rail kit 573091-001 Mandatory 1 3 Hard driv...
Illustrated parts catalog 14 Mechanical components / 8 2.5” HDD hot-plug model Table 3 Mechanical Components Spare Parts List / 8 2.5” HDD Hot-plug Model Item Description Spare Part Number Customer Self Repair 1 Air baffle 511806-001 Mandatory 1 2 Power supply cage 532473-001 Mandatory 1 3 Rail kit ...
Illustrated parts catalog 31 1Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt deze onderdelen te vervangen, komen de reiskosten en het arbeidsloon voor uw rekening. 2Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze o...
Removal and replacement procedures 33 Removal and replacement procedures This chapter provides subassembly/module-level removal and replacement procedures for the HP ProLiant DL160 G6server. Review the specifications of a new component before installing it to make sure it is compatible with the serv...
Removal and replacement procedures 34 Pre-installation procedure Perform the steps below before you open the server or before you remove or replace any component. WARNING: Failure to properly turn off the server before you open the server or before your start installing and removing components may c...
Removal and replacement procedures 35 Server warnings and cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug...
Removal and replacement procedures 36 This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. Weight in kg Weight in lb ...
Removal and replacement procedures 37 3. Slide the cover toward the rear of the server and then lift the top cover to remove it from the chassis. Lift the top cover away from the chassis. Figure 1 Removing the Top Cover To reinstall the top cover: 1. Align the top cover to the chassis and then slide...
Removal and replacement procedures 38 • 8 drive bays for 2.5-inch hard disk drives and 1 drive bay for an optical disc drive. Cable management Always follow good cable management practices when working inside the computer. • Keep cables away from major heat sources like the heat sink. • Do not jam c...
Removal and replacement procedures 42 Drive bay configuration The server supports the following drive bays • 2 drive bays for 3.5-inch hard disk drives and 1 drive bay for 9.5mm (0.37 in.) optical disc drive • 4 drive bays for 3.5-inch hard disk drives and 1 drive bay for 9.5mm (0.37 in.) optical di...
Removal and replacement procedures 44 Figure 7 System Drive Bays / 8 2.5” Hot-plug HDD Model Item Description 1 9.5mm (0.37 in.) optical disk drive 2 2.5 in. hard disk drive bays (8) The HDD bays support both SATA and SAS drives. Optical disc drive bay The optical media device bay of the servers wit...
Removal and replacement procedures 48 Hard drives The drive bays on the front panel can accommodate up to two, four or eight hard drives. You can install either SAS hard drives or SATA hard drives in the server. For servers with 2 3.5-inch HDDs, the hard drives installed in the server are labeled fr...
Removal and replacement procedures 55 3. Fasten the screw with the T-10/T-15 wrench provided to secure the hard drive to the chassis. 4. Connect the cabling from the power supply to the drive using the cables provided. Figure 24 Fastening the Screw SAS/SATA HDD backplane The following figures show t...
Removal and replacement procedures 61 Figure 35 Removing the Backplane To reinstall the backplane: 1. Orient the backplane so that the notches on the backplane align with the hook on the drive cage and then press the backplane down until it clicks into place. 2. Secure the backplane with three screw...
Removal and replacement procedures 71 CAUTION: For proper cooling, do not operate the server without the top cover, air baffle, expansion slot covers, or blanks installed. For additional information, see the user guide. If hot-plug components are supported, minimize the amount of time the top cover ...
Removal and replacement procedures 74 DIMM identification IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the server to halt during BIOS initialization. The memory subsystem may be populated with either RDIMMs or UDIMMs, but mixing the two t...
Removal and replacement procedures 75 PCI expansion card System board PCI expansion slot There are four PCI expansion slots on the system board. Figure 57 System Board PCI Expansion Slot Item Component Designator Component Function 1 J17 PCIe x16 (FH/FL) slot 1a Support a PCIe riser card 2 J3 PCIe x...
Removal and replacement procedures 76 Figure 58 PCIe x16 Riser Card Connector Location • Single-slot PCIe riser card (x16 link with x16 slot) Figure 59 PCIe x8 Riser Card Connector Location • Single-slot PCIe riser card (x4 link with x8 slot) PCI cage To remove the PCI cage: NOTE: Disconnect all cab...
Removal and replacement procedures 77 Figure 60 Removing the PCI Cage Installing PCIe riser card The system supports only two riser card at a time. Use only HP supported expansion boards that meet the following specifications: • Compliance ○ PCIe x16 ○ PCIe x8 • Form Factor ○ Full-Height/Full-Length...
Removal and replacement procedures 88 Figure 80 Inserting security rivet System battery The server uses nonvolatile memory that requires a system battery to retain system information when power is removed. This 3 V lithium coin cell battery is located on the system board. Figure 81 System Battery Lo...
Removal and replacement procedures 91 Figure 85 Reinstalling the BBWC Assembly System board removal and replacement procedure To remove the system board: 1. Remove the top cover. 2. Remove the air baffle and all cables from the system board. 3. Loosen the nine screws that secure the system board to ...
Removal and replacement procedures 96 Figure 95 Fastening the Two Screws beneath the Chassis System fan The server has six system fans located on the center wall of the chassis. In order to provide appropriate cooling to the system and maintain the stability of system temperature, Two kinds of fan l...
Connectors, switches, and LEDs 99 Connectors, switches, and LEDs This chapter contains illustrations and tables identifying and describing the connectors, jumpers, switch, buttons, and LED indicators located on the front panel, rear panel, system board and hard drives of the HP ProLiant DL160 G6 ser...
Connectors, switches, and LEDs 103 Rear panel components Figure 104 Rear Panel Components / Hot-plug Power Supply Model (Optional) Item Description 1 Power supply cable socket 2 Serial port 3 VGA port 4 GbE LAN port for NIC 2 5 Dedicated management port (optional) 6 Full-height/full-length PCI expan...
Connectors, switches, and LEDs 105 System board components Figure 106 System Board Components Item Designator Description 1 J17 PCIe slot 2 J90 Dedicated management port connector 3 J21 DIMM slot 9C for processor 2 4 J77 DIMM slot 1G for processor 2 5 CPU 2 Processor 2 6 CPU 1 Processor 1 7 J74 DIMM...
Connectors, switches, and LEDs 106 Item Designator Description 20 J56 Front panel USB 2.0 port 0/1 21 J11 Mini SAS connector 22 J69 Internal USB 2.0 port 4 23 J29 TPM connector 24 J27 System maintenance jumper Jumpers The system board contains a system maintenance jumper (J27). Table 15 describes th...
Connectors, switches, and LEDs 107 LED indicators This section contains illustration and descriptions of internal and external status LED indicators located on the: • Front panel • Optical disk drive • Hard drive • Rear panel • System board These LED indicators aid in problem diagnosis by indicating...
Connectors, switches, and LEDs 108 Table 16 Front Panel LED Indicators Item LED indicator Status Description Flashing green Linked and activity on the network. Off No connection 4 NIC 2 activity LED Steady green Linked to the network Flashing green Linked and activity on the network. Off No connecti...
Connectors, switches, and LEDs 109 Hard drive LED indicator The status of hard drives installed in the server is indicated by the hard drive LED indicators located on the HDD. Figure 109 Hard Drive LED Indicator Table 18 Hard Drive Activity LED Indicator Status Item LED indicator Status Description ...
Connectors, switches, and LEDs 110 Figure 110 LAN LED Indicators Location Table 19 LAN LED Indicator Status Item Component Status Description 1 NIC link LED indicator Steady green Linking at 100 Mbps speed. Off No connection or linking at 10 Mbps speed. 2 NIC activity LED indicator Flashing green LA...
Diagnostic tools and setup utilities 112 Diagnostic tools and setup utilities This chapter provides an overview of the Power-On Self-Test (POST), the POST error messages, and BIOS, SAS and SATA setup utilities. BIOS software The server uses BIOS to boot up the system. BIOS software is a ROM-based fi...
Diagnostic tools and setup utilities 113 Navigating through the Setup Utility Use the keys listed in the legend bar on the right of the Setup screen to navigate through the various menu and submenu screens of the Setup Utility. Error! Reference source not found. lists these legend keys and their res...
Diagnostic tools and setup utilities 114 Main menu Figure 112 Main Menu of the BIOS Setup Utility ROM-based Setup Utility <Main> Advanced Boot Security Exit System Overview Product Name :Proliant DL160 G6 ProLiant BIOS : O33 Build Date : 01/26/2010 ROM ID : 18DIM191 Processor Intel(R) Xeon(R) ...
Diagnostic tools and setup utilities 115 Advanced menu Figure 113 Advanced Menu of the BIOS Setup Utility ROM-based Setup Utility Main <Advanced> Boot Security Exit Advanced Settings WARNING: Setting wrong values in below sections may cause system to malfunction. Power Efficiency Mode [Efficie...
Diagnostic tools and setup utilities 118 Boot menu Figure 115 Boot Menu of the BIOS Setup Utility ROM-based Setup Utility Main Advanced <Boot> Security Exit Boot Settings ` Boot Settings Configuration ` Standard Boot Order Configure Settings during System Boot. USB Device Boot Priority [High] ...
Diagnostic tools and setup utilities 119 Security menu Figure 116 Security Menu of the BIOS Setup Utility ROM-based Setup Utility Main Advanced Boot <Security> Exit Security Settings Admin Password: Not Installed User Password: Not Installed Change Admin Password Install or Change the Password...
Diagnostic tools and setup utilities 120 Exit menu Figure 117 Exit Menu of the BIOS Setup Utility ROM-based Setup Utility Main Advanced Boot Security Chipset <Exit> Exit Options Save Changes and Exit Discard Changes and Exit Discard Changes Restore Default Settings Exit system setup after savi...
Diagnostic tools and setup utilities 121 BIOS update HP recommends that you update the server BIOS with the latest system BIOS version to take advantage of the most recent compatibility fixes. The latest BIOS version for your server can be downloaded from http://www.hp.com. Clear CMOS You may need t...
Diagnostic tools and setup utilities 122 POST error indicators When POST detects a system failure, it displays a POST error message. POST error descriptions When a recoverable type of error occurs during POST, the screen will display an error message with the format “xxx-Error Identifier String” whe...
Diagnostic tools and setup utilities 123 Table 22 POST Error Messages Error code Description 621 Redundant Fan Configuration, One Fan Failure or Missing 622 Redundant Fan Configuration, Multiple Fans Failure or Missing 623 Temperature Violation Detected Waiting 5 minutes for system to cool Press ESC...
Diagnostic tools and setup utilities 124 SETSYS utility SETSYS.EXE (DOS application) is the correct tool for setting the Serial Number/Asset Tag text on this server after a system board replacement has occurred. Once the Serial Number/Asset Tag text has been entered via SETSYS, populating the SMBIOS...
Physical and operating specifications 125 Physical and operating specifications This chapter provides physical and operating specifications for the HP ProLiant DL160 G6 server. Specifications include: System unit Table 23 Hardware Specifications Item Components Processor socket Intel® FCLGA 1366 soc...
Index 131 Index A AC power power-down procedures, 36 air baffle installing, 71 removing, 63 B backplane, 55 reinstalling, 61 removing, 59 battery replacement warnings, 88 BBWC reinstalling, 90 removing, 90 bezel blank removing, 46 BIOS Setup Utility accessing, 112 additional navigation keys, 113 men...
HP Manuals
-
HP CM1312 MFP
Manual
-
HP DV2700
Manual
-
HP 203A
Manual
-
HP 13-2000
Manual
-
HP 1320NW
Manual
-
HP D4360
Manual
-
HP W19Q
Manual
-
HP FC2143
Manual
- HP ZV6000 Manual
-
HP 7500
Manual
-
HP C4591A
Manual
-
HP E4411B
Manual
-
HP N6310
Manual
- HP nx7000 Manual
-
HP DL120
Manual
- HP w1707 Manual
-
HP CV136A#B1H
Manual
-
HP X585z
Manual
-
HP 686714-S01
Manual
- HP 1200 series Manual