Page 2 - Removing your old thermostat; Check that your system is off.; Make sure there are no; Do you have thick black wires with; Read and save these instructions
2 Quick Installation Guide Removing your old thermostat 2 Check that your system is off. Change the temperature on your old thermostat. If you don’t hear the system turn on within 5 minutes, the power is off. Note: If you have a digital thermostat that has a blank display, skip this step 1 Turn powe...
Page 3 - Y R RC
3 RTH7400/RTH7500 Series 5 Take a picture of how your wiring looks right now. Be sure to include the letters next to the terminals where the wires are inserted. This will be a helpful reference when wiring your thermostat. Tip: If the color of your wires has faded or if 2 terminals have the same wir...
Page 4 - Disconnect the wires and remove the old wall plate.; match the letter on the terminal.; Bundle and insert wires through the UWP.; Pull open the UWP and insert the bundle of
4 Quick Installation Guide 9 Disconnect the wires and remove the old wall plate. Use a screwdriver to release wires from terminals. Then, use a wire label to identify each wire as it’s disconnected. The letter on the wire label should match the letter on the terminal. Tip: To prevent wires from fall...
Page 5 - up
5 RTH7400/RTH7500 Series 11 Insert the wall anchors. It is recommended that you use the wall anchors included in the box to mount your thermostat. You can use the UWP to mark where you want to place the wall anchors. a) Level the wall plate.b) Mark the location of the wall anchors using a pencil. c)...
Page 6 - Mount the UWP and close the; Attach your thermostat.; Connect wires from Step 8.
6 Quick Installation Guide 14 Mount the UWP and close the door. Mount the UWP using the provided screws. Install all three screws for a secure fit on your wall. Close the door after you’re finished. 15 Confirm wiring matches snapshot. Please confirm wiring matches terminals from the photo you took i...
Page 7 - Choose a clock format.; Set date and time
7 RTH7400/RTH7500 Series 18 Turn your power ON. Turn on the power at the breaker box or switch that controls the heating/ cooling system. 19 Set the date. Press + or - to adjust the year. Press Select . Press + or - to adjust the month. Press Select . Press + or - to adjust the day. Press Select . 2...
Page 8 - If this is not a new installation,; Select System Setup options.; Select; Continue to “System operation; System Setup; System Setup options
8 Quick Installation Guide NOTE: If this is not a new installation, see page 14 for entering setup menu. 22 Select System Setup options. Press + or - to change values or select from available options. Then press Select to save changes and advance to the next System Setup number. See “System Setup op...
Page 9 - Once you have cycled through all of the System Setup numbers,; Done; is
9 RTH7400/RTH7500 Series Number Description Options (factory default in bold) 218 Reversing Valve O/B 0 = O (O/B in Cool) 1 = B (O/B in Heat) Note: This option is only displayed if the Heat Pump configured. Select whether reversing valve O/B should energize in cool or in heat. 220 Cool Stages / Comp...
Page 10 - Fan operation settings; Fan; System operation settings; Mode
10 Quick Installation Guide Fan operation settings 1 Press the Fan button to cycle to the next available Fan mode. 2 Cycle through the modes until the required Fan mode is displayed and leave it to activate. NOTE: Available Fan modes vary with system settings. Fan modes: ‒ Auto: Fan runs only when t...
Page 12 - Cancel; Wiring—conventional systems
12 Quick Installation Guide Program schedule override (permanent) Program schedule override (temporary) 1 Press + or - to adjust the temperature. 2 Once at the desired setpoint temperature, no further action is needed. The new setpoint temperature will be held until the next scheduled time period be...
Page 13 - Wiring—heat pump; NOT
13 RTH7400/RTH7500 Series Wiring—heat pump Connect wires: heat pump1 Match each labeled wire with same letter on new thermostat. 2 Insert the wires into the matching terminal. NOTE: If you have difficulty inserting wires, you may have to press down the terminal push button next to the corresponding ...
Page 14 - Advanced menu
14 Quick Installation Guide Advanced menu 1 Press and hold Menu and + buttons for approximately 5 seconds to enter advanced menu. 2 Press Select to enter System Setup (ISU) menu. 3 Press Select to cycle through System Setup numbers. NOTE: See “System Setup options” on page 8 for a full list of Syste...
Page 15 - Smart Response® Technology; Menu; Setting the time
15 RTH7400/RTH7500 Series Smart Response® Technology This feature allows the thermostat to “learn” how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the time you set. For example: Set the Wake time to 6 am, and the temperature to...
Page 16 - PROG; Set the date; Alerts screen
16 Quick Installation Guide 1 Press Menu to enter the device menu. You will see PROG . Press + or - to choose DATE . 2 Press Select . 3 You will see the year blinking. Press + or - to adjust the year. Press Select . 4 Press + or - to adjust the month. Press Select . 5 Press + or - to adjust the day....
Page 17 - Alerts codes
17 RTH7400/RTH7500 Series 3 When the alert icon appears, check the error code with the table below to determine the problem. 4 Snooze the alert. 5 Dismiss the alert. Number Alert/Reminder Definition 170 Internal Memory Error The memory of the thermostat has encountered an error. Please replace the t...
Page 18 - Most problems can be corrected quickly and easily.; Terminal; Troubleshooting
18 Quick Installation Guide If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily. Display is blank Make sure fresh AA alkaline batteries are properly installed (see page 6). Cannot change system setting to Cool Check Sys...
Page 19 - -year limited warranty
19 RTH7400/RTH7500 Series Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) year from the date of first purchase by the original purchaser. If at any time during the warranty period the product...
Page 20 - Customer assistance; CAUTION: MERCURY NOTICE
Resideo Inc., 1985 Douglas Drive North Golden Valley, MN 55422 www.resideo.com 33-00202EF—17 M.S. Rev. 11-20 | Printed in United States © 2020 Resideo Technologies, Inc. All rights reserved.The Honeywell Home trademark is used under license from Honeywell International, Inc.This product is manufactu...
Page 21 - Thermostat programmable; Guide d’installation rapide; Outils requis; Inclus dans cette boîte
Heat Série RTH7400, RTH75000 Thermostat programmable Guide d’installation rapide Outils requis Outils pouvant être requis Dénudeur de fils Pince à bec effilé Perceuse et mèche (Voir l’étape 11) Inclus dans cette boîte Vis et ancres Système de montage UWP™ (UWP) Thermostat RTH7400/RTH7500 Guide d’ins...
Page 22 - Retrait de l’ancien thermostat; D’épais fils noirs sont-ils présents; Veuillez lire le mode d’emploi et le conserver en lieu sûr
2 Guide d’installation rapide Retrait de l’ancien thermostat 2 Vérifiez que l’appareil n’est pas sous tension. Modifiez la température sur l’ancien thermostat. Si le système ne se met pas en marche dans les 5 minutes qui suivent, l’alimentation vers l’appareil est coupée. Remarque : Si vous avez un ...
Page 24 - Débranchez les fils et retirez l’ancienne plaque murale.; Pour éviter que les fils ne tombent derrière le mur, enroulez-les; Regroupez et insérez les fils dans le; Ouvrez le système UWP et insérez le faisceau
4 Guide d’installation rapide 9 Débranchez les fils et retirez l’ancienne plaque murale. Utilisez un tournevis pour dégager les fils des bornes. Utilisez ensuite une étiquette de fil pour identifier chaque fil au fur et à mesure qu’il est débranché. La lettre sur l’étiquette du fil doit correspondre...
Page 27 - Réglage de l’heure et de la date
7 Série RTH7400/RTH7500 18 Rétablissez l’alimentation. Rétablissez l’alimentation au niveau du disjoncteur ou de l’interrupteur contrôlant le système de chauffage/ refroidissement. 19 Réglez la date. Appuyez sur + ou - pour régler l’année. Appuyez sur Select (Sélectionner).Appuyez sur + ou - pour ré...
Page 28 - S’il ne s’agit pas d’une; Configuration du système; Options de configuration du système
8 Guide d’installation rapide REMARQUE : S’il ne s’agit pas d’une nouvelle installation, voir la page 14 pour accéder au menu de configuration. 22 Sélectionnez les options de configuration du système. Appuyez sur + ou - pour changer les valeurs ou sélectionnez l’une des options disponibles. Appuyez ...
Page 29 - Après être passé par tous les numéros de configuration du système,
9 Série RTH7400/RTH7500 Référence Description Options (réglage d’usine en gras) 218 Robinet inverseur O/B 0 = O (O/B sur refroidissement) 1 = B (O/B sur chauffage) Remarque : Cette option ne s’affiche que si la thermopompe est configurée. Sélectionnez si la vanne d’inversion O/B doit s’activer lors ...
Page 30 - Réglages pour le fonctionnement du ventilateur; Réglages pour le fonctionnement du système
10 Guide d’installation rapide Réglages pour le fonctionnement du ventilateur 1 Appuyez sur le bouton Fan (Ventilateur) pour passer au prochain mode de ventilateur disponible. 2 Faites défiler les modes jusqu’à ce que le mode de ventilateur requis s’affiche, et laissez-le s’activer. REMARQUE : Les m...
Page 32 - Câblage—Systèmes conventionnels; Câblage alternatif (systèmes conventionnels)
12 Guide d’installation rapide Dérogation (permanente) au programme Dérogation (temporaire) au programme 1 Appuyez sur + ou - pour régler la température. 2 Une fois la température de consigne souhaitée obtenue, aucune autre action n’est requise. La nouvelle température de consigne est utilisée jusqu...
Page 33 - Câblage—Systèmes à thermopompe; Les étiquettes ne correspondent pas?; Câblage alternatif (pour les thermopompes uniquement); position haute; REMARQUE
13 Série RTH7400/RTH7500 Câblage—Systèmes à thermopompe Branchement des fils : systèmes à thermopompe1 Faire correspondre chaque fil étiqueté avec la lettre sur le nouveau thermostat. 2 Insérez les fils dans les bornes appropriées. REMARQUE : Si vous avez des difficultés à insérer les fils, il se pe...
Page 34 - Menu avancé
14 Guide d’installation rapide Menu avancé 1 Appuyer sur les boutons Menu et + pendant 5 secondes environ pour accéder au menu avancé. 2 Appuyez sur Select (Sélectionner) pour accéder au menu de configuration du système (ISU). 3 Appuyer sur Select (Sélectionner) pour faire défiler les numéros de con...
Page 35 - Technologie Smart Response®; Réglage de l’heure
15 Série RTH7400/RTH7500 Technologie Smart Response® Cette fonctionnalité permet au thermostat « d’apprendre » combien de temps il faut à l’appareil de chauffage et au climatiseur pour atteindre le réglage de température programmé pour que la température voulue soit obtenue à l’heure programmée. Par...
Page 36 - Réglage de la date; Écran d’alerte
16 Guide d’installation rapide 1 Appuyez sur Menu pour entrer dans le menu de l’appareil. PROG s’affiche. Appuyez sur + ou - pour choisir DATE . 2 Appuyez sur Select (Sélectionner). 3 L’année clignote. Appuyez sur + ou - pour régler l’année. Appuyez sur Select (Sélectionner). 4 Appuyez sur + ou - po...
Page 37 - Codes d’alerte; Mettez l’alerte en pause.
17 Série RTH7400/RTH7500 3 Lorsque l’icône d’alerte s’affiche, faites correspondre le code d’erreur avec le tableau ci-dessous pour déterminer le problème. Numéro Alerte/Rappel Définition 170 Erreur de mémoire interne La thermopompe nécessite un entretien. Veuillez remplacer le thermostat. 173 Erreu...
Page 38 - Borne; Dépannage
18 Guide d’installation rapide En cas de difficultés avec le thermostat, essayer les suggestions suivantes. La plupart des problèmes peuvent être réglés rapidement et facilement. Rien n’apparaît à l’écran Assurez-vous que des piles alcalines AA bien chargées sont cor- rectement installées (consultez...
Page 39 - Garantie limitée de 1 an
19 Série RTH7400/RTH7500 Resideo garantit ce produit, à l’exception des piles, contre tout défaut de pièce ou de main- d’oeuvre, durant une période pour un (1) an à partir de la date d’achat par le consommateur d’origine si le produit est utilisé et entretenu convenablement. En cas de défaillance ou...
Page 40 - Service à la clientèle; MISE EN GARDE : AVIS RELATIF AU MERCURE
Resideo Inc., 1985 Douglas Drive North Golden Valley, MN 55422 www.resideo.com 33-00202EF-17 33-00202EF—17 M.S. Rev. 11-20 | Imprimé aux États-Unis © 2020 Resideo Technologies, Inc. Tous droits réservés.La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, ...