Page 2 - English; Contents
English 2 2 Contents 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Introduction . . . . . . . . . . . . . . . . . . .Page 3 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Basic Functions . . . . . . . . . . . . . . . . . . .Page 8 3.0 . . ...
Page 3 - Notes on the Operating Manual; Technical data; failsafe, alibi memory for 2 million inputs optional.
English 3 3 Thank you for choosing this Soehnle Professional product. All the features of this product weredesigned to the state of the art and are optimised for simple and straightforward use.If you have any queries or experience any problems with your appliance not addressed in the operating manua...
Page 4 - Installation and commissioning; Connections; Operating concept, keys and display symbols; The setting options are divided into two function ranges:; Setting mode; Scale 1; Program settings
English 4 4 1.3 Installation and commissioning Before connecting up the appliance, make sure that the power supply complies with the specifica-tions on the appliance nameplate, and the power plug version conforms to local regulations. Placethe connected scales on a level and stable surface. Select a...
Page 6 - Input and control keys
English Input and control keys The following keys are available for input and control: Numeric keys to type in numerical valuesMultiple programming of numeric keys to type in alphabetic characters Calls organisation data Clears last number Info key, electronic nameplate with reference data Scale cha...
Page 7 - SYMBOL BAR; Symbol for standstill
Display The display shows a number of situative views. It is divided into display panes. Additional indicator: Displays second units, weight values for counting, differences with setpoint, etc. Press the F key to activate as required. Symbol bar: Displays information on the status of the activated m...
Page 8 - Basic functions; Zero range limits at power-on; The scale returns to the previous settings when power is restored.; Selecting a program
English 8 8 2. Basic functions The basic functions are similar or identical for all application programs. 2.1 Power on/off Power-on After power-on and during the run-up phase, the Soehnle Professional logo is displayed.The measuring points are briefly listed as they are detected.The scale is zeroed ...
Page 9 - Zeroing; Zero tracking
English 9 9 2.3 Zeroing Press the zeroing key to correct minor deviations from the zero point, e.g. caused by soiling on the scale.Zero range approvable and non-approvable: -1% to +3% of the weighing range. If zeroing is not possible, the error message "Above zero range limit" or "Below ...
Page 10 - Description input; Print key to confirm.; Content input
English 1 10 0 2.6 Organisation data (identifiers) Organisation data help to assign identifiers to document weighing operations,e.g. article number, supplier, machine operator. They are available in all application programs.The Digital Indicator 3020 has 4 organisation data memories. Each memory has...
Page 11 - When an ORG data memory is activated and a print template is stored,; Switching between scales
English 1 11 1 Printout: When an ORG data memory is activated and a print template is stored, values are accepted when you press the Print key and generates a print command. Only the organisation data containing an input are printed out. Show content: Press the ORG key. Press the ORG key repeatedly ...
Page 12 - Alphanumeric input; Types of input box
English 1 12 2 2.9 Alphanumeric input Use the combined numerical/alphanumeric keypad to type in numerical and alphanumeric inputs(similar to a mobile phone keypad). Types of input box - Display boxes with no write option- Display/type-in boxes with numerical input option- Display/type-in boxes with ...
Page 13 - Application programs; Below is a list of application programs available to you:; Weighing and taring; Basic functions: Weighing and measuring gross and net weights.; Basic weighing view
English 1 13 3 3.0 Application programs The various application programs of the Soehnle Program Terminal 3020 offer you numerous solutions for your weighing operations. You can adapt the application programs to your specific needs in Setting mode. Please refer to the detailed manual on the CD under ...
Page 15 - Additive tare; a) Entering tare weights into the fixed tare value memory; value memory is displayed.
English 1 15 5 3.1.6 Additive tare Taring several, even different containers of known weight. See the description of the function in the CD manual. 3.1.7 Provisional tare Unknown tare values are added to the existing tare memory. See the description of the function inthe CD manual. 3.1.8 Automatic t...
Page 16 - b) Changing or overwriting a fixed tare value memory
English 1 16 6 b) Changing or overwriting a fixed tare value memory • Press the Print key and the F key simultaneously; Setting mode appears in the display. • The arrow points to "Program Settings". Confirm by pressing the Print key. • The arrow points to "General". Confirm by pressi...
Page 17 - Error message when taring; Not possible to tare; Display options with the Info key; When you press the Info key, you have the following options:
English 1 17 7 3.1.10 Error message when taring Error 06: Not possible to tare Possible causes: - Scale empty- Scale in overload or underload- Manual tare input with tare value above maximum load 3.1.11 Display options with the Info key When you press the Info key, you have the following options: - ...
Page 18 - Totalising and batching; Totalising
English 1 18 8 3.2 Totalising and batching Totalising means that the individual items are weighed one after the other, the weight is added in the total memory and the scale is then clipped off again at the end of each weighing operation. Batching means that the weighed items remain on the scale, the...
Page 19 - Taring; Taring functions same as for 3.1 Weighing and taring.; Operating the totalising functions; Ending the totalising function; Selection options for total display; See the description of the function in the CD manual.
English 1 19 9 3.2.3 Taring Taring functions same as for 3.1 Weighing and taring. 3.2.4 Operating the totalising functions Press the F key to transfer the weight on the weighing platform to the totalmemory.The item counter and the consecutive number are incremented by 1.Before requesting the next to...
Page 20 - Assigning and clearing the consecutive number; Tare key; = Displays the current tare weight
English 2 20 0 3.2.8 Assigning and clearing the consecutive number Every input in the total memory is assigned a 4-digit consecutive number. The consecutive number is not reset to the factory setting when the total memory is cleared. Optionally, you can default resetting the consecutive number in Se...
Page 21 - Counting; parts with the same weight.; Function key; Function of F key: reference weight calculation; Counting display view; The weight value appears in the additional indicator.; Counting function; Determining the reference weight
English 2 21 1 3.3 Counting Counting parts with the same weight. The single part weight (reference weight) is calculated from a known small quantity of countable parts. This then becomes the divisor to determine thepiece count from the weight of an unknown quantity of countable parts. 3.3.1 Function...
Page 22 - Displaying the reference weight; The weight display appears at the top left of the indicator.; Terminate the count operation; by pressing the C key.; Fixed value memory for reference weights
English 2 22 2 Displaying the reference weight Press the "Info" and "F" keys in succession. Weight display during the counting operation The weight display appears at the top left of the indicator. Terminate the count operation by pressing the C key. Fixed value memory for reference ...
Page 23 - Press the Zeroing and ORG keys (in succession) to quit the list.; Counting with several weighing platforms
English 2 23 3 Saving the new fixed value Entering a new reference value only works in Setting mode "Count/Reference weight fixed value".The memory location number is assigned by the appliance. The first figure in brackets indicates the number of free memory locations; the second figure show...
Page 24 - Checking; Function or F key: setpoint weight; F key
English 2 24 4 3.4 Checking Checks whether the weighing product corresponds to a setpoint weight within a default.tolerance band. Example: If you want to check whether several weighing products This function can also be used for weighing in a default setpoint.Example: You want to fill 50 kg into a c...
Page 25 - Further information
English 2 25 5 4. Further information You will find further information on the following subjects in the detailed documentation, theProgram Terminal 3020 manual, on the supplied CD: - Setting mode- Error messages- Print- Barcode- etc. Ba_3020_GB.qxd 21.06.2007 19:08 Seite 25
Page 28 - Telefon; com
www.soehnle-professional.com F O R M E A S U R A B L E S U C C E S S Soehnle Professional GmbH & Co. KG Manfred-von-Ardenne-Allee 12 71 522 Backnang Telefon +49 (0) 71 9 1 / 34 53 -220 Telefax +49 (0) 71 9 1 / 34 53 -2 11 E-Mail info@soehnle-professional. com S Sc ca al le es s, , S Sy ys st te ...