Smeg KDD90VX - User Manual
Smeg KDD90VX Range Hood – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CHARACTERISTICS; Components
- Page 3 – Dimensions
- Page 4 – INSTALLATION; Ducting version; Recirculation version; Sequence of operations - Installation; Warning; IMPORTANT
- Page 5 – Inserting the Hood Canopy into the support surface from below
- Page 6 – Inserting the Hood Canopy into the support surface from above
- Page 7 – Fixing the Lower Brackets
- Page 8 – Fixing the Squaring Brackets
- Page 9 – Fixing the Motor Unit
- Page 10 – Fixing the Electric Unit
- Page 11 – Connections; DUCTED VERSION AIR EXHAUST SYSTEM
- Page 12 – Fitting the Front element
- Page 13 – Surround Suction Panel
- Page 14 – USE; Control panel
- Page 15 – Remote control panel; Use
- Page 16 – MAINTENANCE; Cleaning the Comfort Panels; Metal grease filters; Resetting the alarm signal
- Page 17 – Activated Charcoal Filter (Recirculation Version); Activating the alarm signal; Lighting unit
EN
2
20
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Accordingly, you may
find descriptions of individual features that do not apply to your specific appliance.
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from incorrect or im-
proper installation.
• Check that the mains voltage corresponds to that indicated on the rating plate fixed to the
inside of the hood.
• For Class I appliances, check that the domestic power supply guarantees adequate
earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm.
The route of the flue must be as short as possible.
• Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers,
fireplaces, etc.).
• If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appli-
ances), a sufficient degree of aeration must be guaranteed in the room in order to prevent
the backflow of exhaust gas. The kitchen must have an opening communicating directly
with the open air in order to guarantee the entry of clean air. When the cooker hood is
used in conjunction with appliances supplied with energy other than electric, the negative
pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into
the room by the cooker hood.
• In the event of damage to the power cable, it must be replaced by the manufacturer or by
the technical service department, in order to prevent any risks.
• If the instructions for installation for the gas hob specify a greater distance specified above,
this has to be taken into account. Regulations concerning the discharge of air have to be
fulfilled.
USE
• The extractor hood has been designed exclusively for domestic use to eliminate kitchen
smells.
• Never use the hood for purposes other than for which it has been designed.
• Never leave high naked flames under the hood when it is in operation.
• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it
does not engulf the sides.
• Deep fat fryers must be continuously monitored during use: overheated oil can burst into
flames.
• Do not flambè under the range hood; risk of fire
• This appliance is not intended for use by persons (including children) with reduced physi-
cal, sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the appliance by a person respon-
sible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• “ CAUTION: Accessible parts may become hot when used with cooking appliances.”.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any mainte-
nance work.
• Clean and/or replace the Filters after the specified time period (Fire hazard).
• Clean the hood using a damp cloth and a neutral liquid detergent.
The symbol
on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be
handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of
correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by
inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your
household waste disposal service or the shop where you purchased the product
.
2°
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
EN 2 21 CHARACTERISTICS Components Ref. Q.ty Product Components 1 1 Hood Canopy complete with: Controls, Light, Filters 2 1 Motor unit 3 1 Electric unit 4 1 Front Frame Ref. Q.ty Installation Components 7.1 2 Splashback Fixing Bracket 7.2 2 Hob Fixing Bracket 7.3 2 Side Bracket 12a 16 Screws 3.5 x 9...
EN 2 22 Dimensions This Cooker hood can be used in conjunction with a Gas Cook Top having the following characteristics: • Maximum power 12,4 kW • 5 fire like the picture 2,6 kW 5 kW 1,9 kW 1,9 kW 1 kW
EN 2 23 INSTALLATION This Hood is set up to be fitted inside the kitchen unit in: • Ducting version : Evacuation to the outside. • Recirculation version : Internal recirculation. Sequence of operations - Installation • Drilling the Support Surface and Fitting the Hood • Connections • Functional Chec...