ResMed 2011-09 - Manual

ResMed 2011-09

ResMed 2011-09 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
Page: / 38

Table of Contents:

  • Page 2 – Making quality of care easy; Making quality of care easy
  • Page 3 – User Guide; English
  • Page 4 – Contents
  • Page 5 – ii; Cleaning and maintenance
  • Page 6 – glish; Introduction; Indications for use
  • Page 7 – Stellar at a glance; WARNING
  • Page 8 – Patient interface; Products; Humidification; Internal battery; CAUTION; ResMed USB stick
  • Page 9 – Mobile use; Setting up for noninvasive use
  • Page 10 – Attaching the H4i heated humidifier for noninvasive use; Setting up for invasive use
  • Page 11 – Trach
  • Page 12 – Working with other optional accessories; Attaching the pulse oximeter; Contraindication; Adding supplemental oxygen
  • Page 13 – Preparing to use a new sensor
  • Page 14 – Connecting a sensor; Attaching an antibacterial filter
  • Page 15 – Stellar basics; About the control panel; Key; Alarm mute
  • Page 16 – LCD screen; Starting therapy; Performing a functional test; Turn off the device by pressing the power switch
  • Page 17 – Check the FiO; Stopping therapy; or
  • Page 18 – Turning off the power; red
  • Page 19 – Tailoring treatment setup options; Setting Ramp
  • Page 20 – Using the menus
  • Page 21 – Setup menu
  • Page 22 – Setup menu: Configuration Menu; Parameter
  • Page 23 – Info menu; Event Summary
  • Page 24 – Data management; Read settings; Write settings and loggings; Daily
  • Page 25 – Weekly; Monthly; Disinfection
  • Page 26 – Multipatient use; Servicing; Troubleshooting; Alarm troubleshooting; Mask; Humidifier
  • Page 28 – finger sensor failure!
  • Page 29 – Other troubleshooting
  • Page 31 – Technical specifications; USB stick is not readable or writeable; Maximum flow
  • Page 33 – Air travel requirements
  • Page 35 – Symbols; Environmental information; General warnings and cautions; WARNINGS; warning
  • Page 36 – CAUTIONS; caution
  • Page 37 – Limited warranty; Product
Loading the manual

Stellar

100

Stellar

150

InvasIve and nonInvasIve
ventIlator

User Guide

English

Global leaders in sleep and respiratory medicine

www.resmed.com

248551/1 2011-09

Stellar 100
Stellar 150

USER

APAC

Protected by patents: AU 2002306200, AU 2002325399, AU 2003204620, AU 2004205275, AU 2004216918, AU 2005200987, AU 2006201573, AU 697652, AU 699726,
AU 713679, AU 731800, AU 737302, AU 739753, AU 746101, AU 756622, AU 757163, AU 759703, AU 773651, AU 779072, CA 2235939, CA 2263126, CA 2266454, CA
2298547, CA 2298553, CN 20020814714.6, CN 200480006230.3, EP 0661071, EP 0858352, EP 0929336, EP 0996358, EP 1005829, EP 1005830, EP 1132106, EP 1175239,
EP 1277435, EP 1687052, JP 3558167, JP 3635097, JP 3638613, JP 3645470, JP 3683182, JP 3730089, JP 3902781, JP 4083154, JP 4597959, JP 4643724, JP 4158958,
JP 4162118, NZ 541914, NZ 546457, NZ 563389, NZ 567617, NZ 577484, US 6152129, US 6213119, US 6240921, US 6279569, US 6484719, US 6532957, US 6553992, US
6575163, US 6644312, US 6659101, US 6688307, US 6755193, US 6810876, US 6840240, US 6845773, US 6945248, US 7089937, US 7137389, US 7255103, US 7367337,
US 7520279, US 7628151, US 7644713, US 7661428. Other patents pending. Protected by design registrations: EU 1768045
ResMed, SmartStart, TiCONTROL, SlimLine, and Stellar are trademarks of ResMed Ltd. ResMed, SmartStart and Stellar are registered in U.S. Patent and Trademark
Office. © 2011 ResMed Ltd

Manufacturer:

ResMed Germany Inc. Fraunhoferstr. 16 82152 Martinsried Germany

Distributed by:

ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia.

ResMed Corp 9001 Spectrum Center Blvd. San Diego, CA 92123 USA.
ResMed (UK) Ltd 96 Milton Park Abingdon Oxfordshire OX14 4RY UK.
See www.resmed.com for other ResMed locations worldwide.

Respiratory Care Solutions

Making quality of care easy

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Making quality of care easy; Making quality of care easy

Respiratory Care Solutions Making quality of care easy Respiratory Care Solutions Making quality of care easy

Page 3 - User Guide; English
Page 4 - Contents

i Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Indications for use 1 Contraindications 1 Adverse effects 1 Stellar at a glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Patient in...

Other ResMed Models

All ResMed Other