- Page 2 – ALERTED; SAFETY AND WARNING INFORMATION; DO NOT
- Page 4 – Appliance Certifi cation; The fi replace model discussed in this; TYPE: Vented Gas Fireplace Heaters; Certifi cation; • A 110-120 VAC circuit for this product must be protected
- Page 5 – T h e f o l l o w i n g r e q u i r e m e n t s r e f e r e n c e va r i o u s
- Page 6 – Getting Started; Introducing Quadra-Fire Gas Fireplaces; Pre-installation Preparation; Owner’s Manual; Do not install any
- Page 7 – Diagram of the QV36DC-A
- Page 8 – Installing the Fireplace; Step 1. Locating the Fireplace; A B C D E; Vertical Sections; Constructing the Fireplace Chase
- Page 9 – Step 2. Framing the Fireplace
- Page 11 – Identifying Vent Components; elbow assemblies. The relationships; WALL FIRESTOP; Step 3. Installing the Vent System
- Page 12 – Straight Up Vertical Venting; STRAIGHT UP; VERTICAL VENTING; Flue Restrictor Instructions; Remove screws with a 1/4 nut driver. Adjust to; CAP; Figure 8
- Page 13 – HORIZONTAL VENTING; Figure 10. Corner Installation
- Page 14 – On vertical venting configurations; Figure 11. Venting with One 90° Elbow; elbow is
- Page 15 – ELBOWS
- Page 16 – Figure 15. Venting with three 90° elbows; V H H + H
- Page 17 – Figure 16. Venting with three 90° elbows
- Page 19 – CORRECT
- Page 22 – = AREA WHERE TERMINAL IS NOT PERMITTED; Alcove Applications; public
- Page 24 – STANDING PILOT; Step 5. The Gas Control System; Standing Pilot Ignition System
- Page 25 – Step 6. The Gas Supply Line; NOTE; Step 7. Gas Pressure Requirements; Pressure Natural; Minimum; Figure 33. Gas Supply Line
- Page 26 – Step 8. Wiring the Fireplace; Appliance Requirements; This appliance; DOES NOT
- Page 27 – F. MINIMUM SEALANT MATERIAL; Hearth Extensions; require hearth extensions for gas fi replace appliances.; There are 3 metal tabs holding the non-combustible
- Page 28 – overlap onto the front face. The joints
- Page 29 – Step 11. Before Lighting the Fireplace; Step 12. Lighting the Appliance
- Page 30 – WHAT TO DO IF YOU SMELL GAS
- Page 31 – After the Installation; LEAVE THIS INSTALLATION MANUAL WITH; Maintaining and Servicing Your Fireplace; Fireplace Maintenance; Placing Ember Material; Step 13 Climate Control
- Page 32 – A. Standing Pilot Ignition System; Symptom; Troubleshooting
- Page 33 – Replace glass panel assembly.
- Page 34 – Limited Lifetime Warranty
- Page 36 – Contact Information; DO NOT DISCARD THIS MANUAL; CAUTION; • Leave this manual with; For the location of your nearest Quadra-Fire dealer,
Quadra-Fire • QV36DC-A • 2161-900 Rev. C • 6/09
1
Model:
QV36DC-A
Owner’s Manual
Installation and Operation
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
HOT SURFACES
!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
•
DO NOT
touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
WARNING
• C A R E F U L LY S U P E RV I S E c h i l d r e n i n s a m e r o o m a s
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
DO NOT DISCARD THIS MANUAL
CAUTION
Important operating and
maintenance instruc-
tions included.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280
or
Standard for Installation in Mobile
Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory-trained
professionals, or technicians supervised by an NFI
certifi ed professional.
•
•
•
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Read, understand and follow
these instructions for safe
installation and operation.
Leave this manual with
party responsible for use
and operation.
DO NO
T
DISCARD
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
R
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Quadra-Fire • QV36DC-A • 2161-900 Rev. C • 6/09 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Owner’s Manual . NO OTHER vent systems or components MAY BE USED. This gas fi replace and vent assembly MUST be vented directly to the outside and M...
Quadra-Fire • QV36DC-A • 2161-900 Rev. C • 6/09 7 1 Approvals and Codes Appliance Certifi cation The fi replace model discussed in this Owner’s Manual has been tested to certifi cation standards and listed by the applicable laboratories. MODELS: QV36DC-A LABORATORY: Underwriters Laboratories, Inc. (...
Quadra-Fire • QV36DC-A • 2161-900 Rev. C • 6/09 8 Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by t...