Quadra-Fire 839-1320 - Manual

Quadra-Fire 839-1320

Quadra-Fire 839-1320 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
Page: / 56

Table of Contents:

  • Page 2 – Manufactured Date; SAMPLE; Barcode
  • Page 4 – Listing and Code Approvals; cation; This installation must conform with local codes. In the; National; and the; CAN/CGA B149 Installation Codes; D. High Altitude Installations; WARNING; Model; F. Combustible Materials
  • Page 6 – Getting Started; and national codes and regulations.; CAUTION; B. Tools and Supplies Needed; tools will apply to every installation.; • Installation and use of any damaged appliance or vent; Any such action may cause a; warranty will be; Report damaged parts to dealer.
  • Page 7 – Appliance Location and Clearances; A. Selecting Appliance Location
  • Page 8 – Page 8; Termination Locations; A. Vent Termination Minimum Clearances; specifi es minimum vent heights for various; • Do not pack air space with insulation or
  • Page 9 – Page 9; = AREA WHERE TERMINAL IS NOT PERMITTED; public; Alcove Applications
  • Page 10 – Vent Information; A. Venting Components; • Vent this appliance directly outside.; Figure; C. Measuring Standards; ALL vent confi guration specifi cations MUST be followed.
  • Page 11 – NOTES; VERTICAL DISTANCE; Vertical Termination
  • Page 12 – F. Horizontal Termination; A Snorkel Kit is; Note; : Female ends of direct vent pipe/elbows are designed
  • Page 13 – 5° Elbow in Corner Installation; Top Vent; (2) The location of the horizontal vent termination on an; (1) The four wood screws provided should be replaced
  • Page 14 – Local codes may require installation of a cap; If you are installing termination cap HHW2, the; Impaired Performance of Appliance.; • Ensure vent components are locked together correctly.; The attachment from the vent pipe to the vent
  • Page 15 – Check the instructions below for maximum vertical rise; NOTE; : Maximum number of 45° elbows permitted for a; G. Vertical Termination; • Do not pack air space with insulation or other
  • Page 16 – ) If an offset is necessary in the attic to avoid obstructions,
  • Page 17 – • Any occupied areas above the first floor, including; For multi-story vertical installations, a ceiling firestop
  • Page 18 – TRIM COLLAR
  • Page 19 – Class A Metal Chimney; Top Adapter; Remove existing chimney cap.
  • Page 20 – Existing Masonry Chimney; (see Section 12 for conversion kit and
  • Page 22 – ). Mount the retro connector to the masonry wall using; wind termination cap on to the top adapter.
  • Page 23 – Gas Information; Converting to LP Gas; Opens Left
  • Page 24 – Valve Regulator Replacement; Disconnect any electrical cords and; NOTE: Do not remove the retaining clip from the hood.
  • Page 25 – PRESSURE
  • Page 26 – • If substituting for these components, please consult local; We recommend
  • Page 27 – Electrical Information; A. Recommendation for Wire; DOES NOT; This appliance must be electrically wired and; National Electric Code ANSI/NFPA; or the; Canadian Electric Code, CSA; Wire Size
  • Page 28 – • Wire must have high temperature insulation.; Ignitor; Thermopile; VALVE
  • Page 29 – Appliance Setup; A. Remove Shipping Materials; Sharp Edges
  • Page 30 – C. Leg Leveling System
  • Page 31 – For BOTH Quartet and Solitaire Fronts:; Solitaire Front; Spacer; F. Brick Installation
  • Page 32 – G. Positioning the Logs; Description
  • Page 33 – Locater Pins; To complete your log set applica-; • Follow ember placement instructions in
  • Page 34 – J. Blower Installation; FROM THE KIT YOU WILL NEED:; I. Glass Door Assembly Replacement; Handle glass assembly with care.; • Replace glass assembly as a complete
  • Page 35 – Figure 8.31 Blower Wiring Diagram
  • Page 36 – K. Damper Adjustment; TOP VENT INSTALLATIONS:; L. Shutter Adjustment; FOR TOP OR REAR VENT INSTALLATIONS; OPEN
  • Page 37 – Operating Instructions; A. Before Lighting Appliance; Fumes; • Keep children away.; PILOT IGNITOR
  • Page 38 – C. Lighting Appliance; WHAT TO DO IF YOU SMELL GAS:; result causing property damage, personal injury or loss of life
  • Page 39 – D. After Appliance is Lit; Initial Break-in Procedure; E. Frequently Asked Questions; ISSUE
  • Page 40 – Troubleshooting; Symptom
  • Page 41 – Check the burner orifi ce for stoppage. Remove stoppage.
  • Page 43 – USE CAUTION WHEN CLEANING/HANDLING CERAMIC BURNER.; A. Maintenance Tasks
  • Page 44 – Reference Materials; A. Appliance Dimension Diagram
  • Page 45 – B. Vent Components Diagram; Figure 12.2 SL-D Series Vent Components
  • Page 46 – MISCELLANEOUS
  • Page 47 – Service Parts List; TOPAZ
  • Page 48 – Item
  • Page 50 – CAST PARTS - INDIVIDUAL PIECES
  • Page 51 – Accessories
  • Page 52 – Lifetime Warranty; LIMITED LIFETIME WARRANTY
  • Page 53 – THIS PAGE INTENTIONALLY
  • Page 56 – CONTACT INFORMATION; DEALERSHIP WHERE PURCHASED:; Your Records for Model:; Topaz; For the number of your nearest Quadra-Fire dealer; G. Contact Information
Loading the manual

www.quadrafi re.com

January 3, 2007

7009-113E

Quartet Front

Solitaire Front

TOPAZ

DIRECT VENT ROOM HEATER

Owner’s Manual

Installation and Operation

Model:

839-1290
839-1320
839-1340
844-4120

R

Tested and

Listed by

Beaverton

Oregon USA

OMNI- Test Laboratories, Inc.

C

US

DO NOT DISCARD THIS MANUAL

CAUTION

• Important operating and

maintenance instructions
included.

• L e a v e t h i s m a n u a l w i t h

party responsible for use
and operation.

• Read, understand and

follow these instructions
for safe installation and
operation.

• Do not store or use gasoline or other fl am-

mable vapors and liquids in the vicinity of this
or any other appliance.

• What to do if you smell gas

- D o n o t t r y t o l i g h t a n y a p p l i a n c e .

Do not touch any electrical switch. Do not
use any phone in your building.

- Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

- If you cannot reach your gas supplier, call

the fi re department.

• Installation and service must be performed

by a qualifi ed installer, service agency, or the
gas supplier.

WARNING: If the information in these
instructions is not followed exactly, a

fi

re

or explosion may result causing property
damage, personal injury, or death.

This appliance may be installed as an OEM installation in manufactured
home (USA only) or mobile home and must be installed in accordance with
the manufacturer's instructions and the manufactured home construction
and safety standard, Title 24 CFR, Part 3280 or Standard for Installation
in Mobile Homes, CAN/CSA Z240MH.

This appliance is only for use with the type(s) of gas indicated on the
rating plate.

Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory-trained
professionals, or technicians super-
vised by an NFI certifi ed professional.

WARNING

Glass and other surfaces are hot during oper-
ation and cool down.

• Keep

children

away.

• CAREFULLY SUPERVISE children in same

room as appliance.

HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.

• Alert children and adults to hazards of high temperatures.
• Do NOT operate with protective barriers open or removed.
• Keep clothing, furniture, draperies and other combustibles

away.

DO NO

T

DISCARD

In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber or gas

fi tter.

See Table of Contents for additional Commonwealth of Mas-
sachusetts requirements.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Manufactured Date; SAMPLE; Barcode

Page 2 Quadra-Fire · Topaz · 7009-113E January 3, 2007 Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market...

Page 4 - Listing and Code Approvals; cation; This installation must conform with local codes. In the; National; and the; CAN/CGA B149 Installation Codes; D. High Altitude Installations; WARNING; Model; F. Combustible Materials

Page 4 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 1 Listing and Code Approvals The product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre-ational Vehicles” and "Gas Fired Appliances f...

Page 6 - Getting Started; and national codes and regulations.; CAUTION; B. Tools and Supplies Needed; tools will apply to every installation.; • Installation and use of any damaged appliance or vent; Any such action may cause a; warranty will be; Report damaged parts to dealer.

Page 6 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 2 Getting Started Check building codes prior to installation.• Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fi re offi cials or authorities having jurisdiction about restricti...

Other Quadra-Fire Models

All Quadra-Fire Other