Page 2 Quadra-Fire · Topaz · 7009-113E January 3, 2007 Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market...
Page 4 - Listing and Code Approvals; cation; This installation must conform with local codes. In the; National; and the; CAN/CGA B149 Installation Codes; D. High Altitude Installations; WARNING; Model; F. Combustible Materials
Page 4 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 1 Listing and Code Approvals The product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre-ational Vehicles” and "Gas Fired Appliances f...
Page 6 - Getting Started; and national codes and regulations.; CAUTION; B. Tools and Supplies Needed; tools will apply to every installation.; • Installation and use of any damaged appliance or vent; Any such action may cause a; warranty will be; Report damaged parts to dealer.
Page 6 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 2 Getting Started Check building codes prior to installation.• Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fi re offi cials or authorities having jurisdiction about restricti...
Page 7 - Appliance Location and Clearances; A. Selecting Appliance Location
January 3, 2007 Page 7 Quadra-Fire · Topaz · 7009-113E 3 Appliance Location and Clearances A. Selecting Appliance Location NOTE: · Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY. · Illustrations/diagrams are not drawn to scale. · Actual installation may vary due to ind...
Page 8 - Page 8; Termination Locations; A. Vent Termination Minimum Clearances; specifi es minimum vent heights for various; • Do not pack air space with insulation or
Page 8 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 4 Termination Locations A. Vent Termination Minimum Clearances 24 in. (610mm) (minimum) to Perpendicular Wall (Gas Only) A 18 in. (457mm) Gas or Wood Termination Gas Termination Gas Termination A 6 in. (152mm) Wood & Fuel Oil Termination 20 ...
Page 9 - Page 9; = AREA WHERE TERMINAL IS NOT PERMITTED; public; Alcove Applications
January 3, 2007 Page 9 Quadra-Fire · Topaz · 7009-113E Figure 4.4 V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inches ............. clearances above grade, veran- da, porch, deck or balcony B = 12 inches ............ clearances to window or door that may be op...
Page 10 - Vent Information; A. Venting Components; • Vent this appliance directly outside.; Figure; C. Measuring Standards; ALL vent confi guration specifi cations MUST be followed.
Page 10 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 5 Vent Information A. Venting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only following venting components: • Hearth & Home Technologies (HHT) • Security Chimney's Secure Vent Chimney Sy...
Page 11 - NOTES; VERTICAL DISTANCE; Vertical Termination
January 3, 2007 Page 11 Quadra-Fire · Topaz · 7009-113E D. How to Use the Vent Graph E. Venting Guidelines 1. Measure the vertical distance from the center line of the flue pipe to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis acro...
Page 12 - F. Horizontal Termination; A Snorkel Kit is; Note; : Female ends of direct vent pipe/elbows are designed
Page 12 January 3, 2007 Quadra-Fire · Topaz · 7009-113E Female Locking Lugs Male Locking Lugs Step 1. Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached. If this is the case, you may want to adjust t...
Page 13 - 5° Elbow in Corner Installation; Top Vent; (2) The location of the horizontal vent termination on an; (1) The four wood screws provided should be replaced
January 3, 2007 Page 13 Quadra-Fire · Topaz · 7009-113E Figure 5.5 When installing the Sapphire in a rear vent configuration with no vertical rise: a Snorkel Kit must be used, and a derating orifice must be installed. The appropriate orifice is supplied with the Rear Vent Kit . 45° Elbow in Corner I...
Page 14 - Local codes may require installation of a cap; If you are installing termination cap HHW2, the; Impaired Performance of Appliance.; • Ensure vent components are locked together correctly.; The attachment from the vent pipe to the vent
Page 14 January 3, 2007 Quadra-Fire · Topaz · 7009-113E Step 5. Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent termination cap assembly. It is important that the vent pipe extend into the...
Page 15 - Check the instructions below for maximum vertical rise; NOTE; : Maximum number of 45° elbows permitted for a; G. Vertical Termination; • Do not pack air space with insulation or other
January 3, 2007 Page 15 Quadra-Fire · Topaz · 7009-113E Step 1. Check the installation instructions for required 1 in. (25mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. See page 16, Figure 5.16....
Page 16 - ) If an offset is necessary in the attic to avoid obstructions,
Page 16 January 3, 2007 Quadra-Fire · Topaz · 7009-113E Step 4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position. Assemble as instructed. Step 5....
Page 17 - • Any occupied areas above the first floor, including; For multi-story vertical installations, a ceiling firestop
January 3, 2007 Page 17 Quadra-Fire · Topaz · 7009-113E MIN. 1 in. (25mm)CLEARANCE CEILING FIRES TOP NAILS MIN. 1 in. (25mm)CLEARANCE MIN. 1 in. (25mm)CLEARANCE MIN. 1 in. (25mm)CLEARANCE Figure 5.16 Fire Risk. Explosion Risk. WARNING • Any occupied areas above the first floor, including closets and...
Page 18 - TRIM COLLAR
Page 18 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 2. Cathedral Ceiling LEVEL CATHEDRAL CEILINGSUPPORT BOX 2 in. (51mm)MIN. BELOWFINISHEDCEILING CUT HOLE 1/8 in.(3mm) GREATER INSIZE THAN PATTERNOF SUPPORT BOX ASIT IS PROJECTEDONTO ROOF LINE Figure 5.17 Figure 5.18 Step 1. Follow installation St...
Page 19 - Class A Metal Chimney; Top Adapter; Remove existing chimney cap.
January 3, 2007 Page 19 Quadra-Fire · Topaz · 7009-113E 3. Class A Metal Chimney Figure 5.20 HIGH WINDTERMINATIONCAP SHEET METALSCREWS DRILL FOUR 1/8 in.(3mm) DIAMETERHOLES Figure 5.22 Figure 5.23 Step 4. Pass the flex pipe down through the center of the chimney system, and center the top adapter on...
Page 20 - Existing Masonry Chimney; (see Section 12 for conversion kit and
Page 20 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 4. Existing Masonry Chimney Type A - Up & Out Installations for Top Vent Configurations Figure 5.24 Type B - Hearth Rear Vent Installations for Use With Rear Vent Kit (see Section 12 for conversion kit and venting components.) Chimney Liner...
Page 22 - ). Mount the retro connector to the masonry wall using; wind termination cap on to the top adapter.
Page 22 January 3, 2007 Quadra-Fire · Topaz · 7009-113E HIGH WIND TERMINATION CAP TOP ADAPTER THREE SHEET METAL SCREWS FLASHING Step 9. Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector ( Figure 5.29 ). Mount the retro connector to the mas...
Page 23 - Gas Information; Converting to LP Gas; Opens Left
January 3, 2007 Page 23 Quadra-Fire · Topaz · 7009-113E 6 Gas Information A. Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type. Any natural or propane gas conversions necessary to meet the appliance and locality needs m...
Page 24 - Valve Regulator Replacement; Disconnect any electrical cords and; NOTE: Do not remove the retaining clip from the hood.
Page 24 January 3, 2007 Quadra-Fire · Topaz · 7009-113E A B C Figure 6.8 Turn control knob to the OFF position, ensure that gas supply to the valve has been turned off. Using a Torx TH20, or slotted screwdriver, remove the three pressure reg-ulator mounting screws (A) , pressure regulator tower (B) ...
Page 25 - PRESSURE
January 3, 2007 Page 25 Quadra-Fire · Topaz · 7009-113E Fire Risk.Explosion Risk. • If the information in these instructions is not followed exactly, a fi re, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. • The qualifi ed service agen...
Page 26 - • If substituting for these components, please consult local; We recommend
Page 26 January 3, 2007 Quadra-Fire · Topaz · 7009-113E • A small amount of air will be in the gas supply lines. When fi rst lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally. Air only needs to be purged a...
Page 27 - Electrical Information; A. Recommendation for Wire; DOES NOT; This appliance must be electrically wired and; National Electric Code ANSI/NFPA; or the; Canadian Electric Code, CSA; Wire Size
January 3, 2007 Page 27 Quadra-Fire · Topaz · 7009-113E 7 Electrical Information A. Recommendation for Wire C. Standing Pilot Ignition System Wiring See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch. B. Connecting to the Appliance This appliance DOES NOT r...
Page 28 - • Wire must have high temperature insulation.; Ignitor; Thermopile; VALVE
Page 28 January 3, 2007 Quadra-Fire · Topaz · 7009-113E Figure 7.1 CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Shock hazard.• Replace damaged wire with type 105 O C rated wi...
Page 29 - Appliance Setup; A. Remove Shipping Materials; Sharp Edges
January 3, 2007 Page 29 Quadra-Fire · Topaz · 7009-113E 8 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Top to Rear Vent Conversion Figure 8.1 Remove top trivet, if installed. Remove vent pipe adapter and gasket. If gasket breaks, a...
Page 30 - C. Leg Leveling System
Page 30 January 3, 2007 Quadra-Fire · Topaz · 7009-113E D. Accessories Install approved accessories per instructions included with accessories. Refer to Section 12 for appropriate accesso-ries. Shock or fi re risk.Use ONLY optional accessories approved for this appliance.• U s i n g n o n - l i s t ...
Page 31 - For BOTH Quartet and Solitaire Fronts:; Solitaire Front; Spacer; F. Brick Installation
January 3, 2007 Page 31 Quadra-Fire · Topaz · 7009-113E E. Front Installation Fronts shipped attached to face Figure 8.12 To remove the face, loosen the thumb bolt beneath the ashlip. Figure 8.13 Lift up on the top of the Front, gently pulling out on the bottom. Set aside in a safe location. For BOT...
Page 32 - G. Positioning the Logs; Description
Page 32 January 3, 2007 Quadra-Fire · Topaz · 7009-113E NOTE: Side brick panels will fit only if installed at an angle. Do not attempt to push the brick flat against the outer wall of the firebox. Brick should rest against spacer on inside of firebox. Figure 8.16 Install left or right side panel. Pl...
Page 33 - Locater Pins; To complete your log set applica-; • Follow ember placement instructions in
January 3, 2007 Page 33 Quadra-Fire · Topaz · 7009-113E Figure 8.20 Insert locator pin into right front log. Insert rear log onto log pan over stud. Figure 8.22 Insert locator pin into right front log. Place right front log on burner in the grooves provided on the burner surface. Locater Pins Figure...
Page 34 - J. Blower Installation; FROM THE KIT YOU WILL NEED:; I. Glass Door Assembly Replacement; Handle glass assembly with care.; • Replace glass assembly as a complete
Page 34 January 3, 2007 Quadra-Fire · Topaz · 7009-113E NOTE: This blower utilizes a snap disc to control ON and OFF operation. When the correct temperature is reached, the blower will automatically turn ON. Use the rheostat knob to adjust the fan to High or Low to suit your preferences. Figure 8.29...
Page 35 - Figure 8.31 Blower Wiring Diagram
January 3, 2007 Page 35 Quadra-Fire · Topaz · 7009-113E SNAP DISC 6 in. (152mm) BLACK BLOWER 4 in. (102mm) WHITE CORD M F M F 34 in. (864mm) BLACK 34 in. (864mm) WHITE F M M F RHEOSTAT F F M F Figure 8.31 Blower Wiring Diagram
Page 36 - K. Damper Adjustment; TOP VENT INSTALLATIONS:; L. Shutter Adjustment; FOR TOP OR REAR VENT INSTALLATIONS; OPEN
Page 36 January 3, 2007 Quadra-Fire · Topaz · 7009-113E See Vent Graph for Recommendations on page 11 before you begin your adjustment. If your installation falls within the range of the gray shaded area of graph, it may be necessary to make an adjustment to the vertical damper to improve the flame ...
Page 37 - Operating Instructions; A. Before Lighting Appliance; Fumes; • Keep children away.; PILOT IGNITOR
January 3, 2007 Page 37 Quadra-Fire · Topaz · 7009-113E 9 Operating Instructions A. Before Lighting Appliance Read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, bodily injury, or even death. Glass door must be in place when applian...
Page 38 - C. Lighting Appliance; WHAT TO DO IF YOU SMELL GAS:; result causing property damage, personal injury or loss of life
Page 38 January 3, 2007 Quadra-Fire · Topaz · 7009-113E C. Lighting Appliance 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position. FOR YOUR SAFETY REA...
Page 39 - D. After Appliance is Lit; Initial Break-in Procedure; E. Frequently Asked Questions; ISSUE
January 3, 2007 Page 39 Quadra-Fire · Topaz · 7009-113E D. After Appliance is Lit When you light your appliance, you may notice that it pro-duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high...
Page 40 - Troubleshooting; Symptom
Page 40 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 10 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualifi ed service person in the dia...
Page 41 - Check the burner orifi ce for stoppage. Remove stoppage.
January 3, 2007 Page 41 Quadra-Fire · Topaz · 7009-113E Symptom Possible Cause Corrective Action 3. (Continued) c. Defective valve. Turn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter at the thermopile terminals. The millivolt meter should re...
Page 43 - USE CAUTION WHEN CLEANING/HANDLING CERAMIC BURNER.; A. Maintenance Tasks
January 3, 2007 Page 43 Quadra-Fire · Topaz · 7009-113E Inspect Maintenance Tasks Doors 1. Inspect for scratches, dents or other damage and repair as necessary. 2. Verify no obstructions to air fl ow. 3. Verify maintenance of proper clearance to combustible household objects. Gasket Seal, Glass Asse...
Page 44 - Reference Materials; A. Appliance Dimension Diagram
Page 44 January 3, 2007 Quadra-Fire · Topaz · 7009-113E 12 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For clearances refer to Section 3. Figure 12.1 Appliance Dimensions B C A K L M N O D E F G H I J Location Inches Millimet...
Page 45 - B. Vent Components Diagram; Figure 12.2 SL-D Series Vent Components
January 3, 2007 Page 45 Quadra-Fire · Topaz · 7009-113E B. Vent Components Diagram Figure 12.2 SL-D Series Vent Components 4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe 9-1/4 in. (235mm) 6-1/2 in. (165mm) 6-5/8 in. (168mm) 17-24 in. (432-610mm) 11-3/4 in. (298mm) 5-3/4 in. (146mm) 6-5/8 in...
Page 46 - MISCELLANEOUS
Page 46 January 3, 2007 Quadra-Fire · Topaz · 7009-113E C. Vent Components List COMPONENTS 930D Ceiling Support / Wall Thimble, Black 941 Cathedral Ceiling Support, Black 942 Wall Thimble 908B 6 inch Pipe Length, Black 907B 9 inch Pipe Length, Black 906B 12 inch Pipe Length, Black 904B 24 inch Pipe ...
Page 47 - Service Parts List; TOPAZ
January 3, 2007 Page 47 Quadra-Fire · Topaz · 7009-113E D. Service Parts List R TOPAZ (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 12-8-03Ending Manufacturing Date: Item # Description Item # Description Item # Description 1 Face Assembly, Quartet 10 Bulkhead 19 Switch, Rocker, ON/OF...
Page 48 - Item
Page 48 January 3, 2007 Quadra-Fire · Topaz · 7009-113E IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts. D. Service Parts List (cont’d.) R TOPAZ (NG, LP) Exploded P...
Page 50 - CAST PARTS - INDIVIDUAL PIECES
Page 50 January 3, 2007 Quadra-Fire · Topaz · 7009-113E Orifi ce, Pilot, NG, EZ, #62 842-4440 Paint, Touch-up, Matte Black 7000-304 Paint, Touch-up, Porcelain Mahogany 855-1450 Paint, Touch-up, Powder Coat Crème TOUCHUP-CCR Paint, Touch-up, Powder Coat Linden Green TOUCHUP-CLG 5 Pilot Assembly, NG 8...
Page 51 - Accessories
January 3, 2007 Page 51 Quadra-Fire · Topaz · 7009-113E Part Description Alphabetical Order Part # Blower Assembly with Speed Control (Rheostat) BK-GAS Decorative Glass Accent for Solitaire Front, Gold 844-0140 Warming Shelves, Matte Black 844-9780 Warming Shelves, Porcelain Mahogany 844-9810 Warmin...
Page 52 - Lifetime Warranty; LIMITED LIFETIME WARRANTY
Page 52 January 3, 2007 Quadra-Fire · Topaz · 7009-113E F. Warranty Policy Lifetime Warranty R LIMITED LIFETIME WARRANTY The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home Tech...
Page 53 - THIS PAGE INTENTIONALLY
January 3, 2007 Page 53 Quadra-Fire · Topaz · 7009-113E THIS PAGE INTENTIONALLY LEFT BLANK.
Page 56 - CONTACT INFORMATION; DEALERSHIP WHERE PURCHASED:; Your Records for Model:; Topaz; For the number of your nearest Quadra-Fire dealer; G. Contact Information
Page 56 Quadra-Fire · Topaz · 7009-113E January 3, 2007 Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HHT INDUSTRIES CONTACT INFORMATION : DEALERSHIP WHERE PURCHASED: ______________________________________ ______________________________________ ____________________...