Quadra-Fire 810-03201 - Manual

Quadra-Fire 810-03201

Quadra-Fire 810-03201 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – Page 2; SAMPLE OF CLEARANCE TO COMBUSTIBLES LABEL; Castile Pellet Insert; CAUTION; Mfg Date; SAMPLE OF SERIAL NUMBER & DATE OF MANUFACTURE LABEL
  • Page 3 – Page 3; B. Clearances to Combustibles; Horizontal; TABLE OF CONTENTS
  • Page 4 – Listing and Code Approvals; A. Appliance Certifi cation
  • Page 5 – Getting Started; Warning! Risk of Fire; Appliance Location; NOTICE: Check building codes prior to installation.; Frequently open doors
  • Page 6 – • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
  • Page 7 – Report damaged parts to dealer.; Or any such action that may cause a fi re hazard.; WARNING
  • Page 8 – Page 8; Dimensions and Clearances; A. Appliance Dimensions; : All views are shown with Panel
  • Page 9 – Illustrations refl ect typical installations; Inches; INSTALLED AS A BUILT-IN UNIT; ” (0mm) Clearance To Exposed Section And Face Trim; Outside
  • Page 11 – Starter hole; F. Removing Metal Floor of Factory-Built Firebox
  • Page 12 – Figure; G. Prefabricated Metal Chimney
  • Page 13 – Do not terminate vent; in any enclosed or semi-enclosed; A. Chimney and Exhaust Connection; Chimney & Connector; INSTALL VENT AT CLEARANCES SPECIFIED BY THE
  • Page 14 – D. Pipe Selection Chart; ALTITUDE IN THOUSANDS OF FEET; Example 1; : If the equivalent length of pipe is 23 feet with altitude of; Example 2; : If the equivalent length of pipe is 12 feet with altitude of
  • Page 15 – Venting Systems; A. Full Reline With Outside Air - Horizontal
  • Page 16 – Check clearances carefully for this type of instal-; national codes and regulations.; In Canada only a full reline is allowed per ULC; B. Full Reline With Outside Air - Vertical; Outside Air; In Canada this fi replace insert must be installed
  • Page 17 – Mobile Home; pages 9; for listings to combus-; A. Mobile Home Installation; Spark Arrestor Cap; NEVER INSTALL IN A SLEEPING ROOM.
  • Page 18 – Ammo Can Latches; Top Vent Installation; screw; NOTE
  • Page 19 – Parts Included in Kit:; D. Zero Clearance Trim Support Instructions; Item
  • Page 20 – Install Sides; Turn right side up and attach top cast rin g; Zero Clearance Panel Extension; Base Plate Only Installation; Parts Needed
  • Page 21 – E. Panel Set And Cast Trim Set; Included in Panel Kit:; See Figures; Powered Phillips head screw driver; Do NOT pick up assembled unit by corners.
  • Page 22 – Open the hinged cast face and open the glass door; Four Piece Log Set Installation; G. Optional Log Set Placement Instructions; Notch; Top Log Installation
  • Page 23 – H. Thermostat Installation; Control Box
  • Page 24 – Operating Instructions; in length; . Pellet lengths may even vary by lot from the same; If you burn pellets longer than 1-1/2 inches; Shelled Field Corn; Do NOT purchase fuel
  • Page 25 – Thermostat Calls For Heat; automatically light and deliver; Heat Output Controls; C. Before Your First Fire
  • Page 26 – set loose at the factory; F. Feed Rate Adjustment; bustibles to appliance; DO NOT LEAVE FIREPOT FLOOR OPEN
  • Page 27 – Odors and vapors released during initial operation.; ISSUES; Noise is caused by metal expanding and contracting as
  • Page 28 – Troubleshooting; This troubleshooting guide can only be used by a qualifi ed; Symptom; Possible Cause
  • Page 31 – Maintaining & Servicing Your Appliance; in this section for more details on fuels with; Shock and Smoke Hazard; A. Proper Shutdown Procedure; Cleaning or Inspection; Frequency; B. Quick Reference Maintenance Chart; Not properly
  • Page 32 – Cleaning Firepot with Cleaning Rod & Firepot; Remove Cast Sides for Cleaning & Maintenance
  • Page 33 – Disposal of Ashes; • Ashes should be placed in metal container; 0 Heat Exchanger Tubes
  • Page 34 – • Do NOT operate with glass cracked, broken or
  • Page 35 – Preparing Firebox for Non-Burn Season; D. High Ash Fuel Content Maintenance; is shown in; IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.
  • Page 36 – E. Igniter Replacement; • Glass is 5mm thick high temperature heat-; Glass; Igniter
  • Page 37 – Figures; Tabs
  • Page 39 – Reference Materials; A. Component Function
  • Page 40 – Wiring Harness
  • Page 41 – Feed Motor
  • Page 48 – Date of Service; E. Service And Maintenance Log
  • Page 52 – Location on appliance:; We recommend that you record the following pertinent; DO NOT DISCARD THIS MANUAL; • Important operating and; DO NOT
Loading the manual

R

www.quadrafi re.com

250-7251G

August 20, 2009

CASTILE PELLET INSERT

O - T L

Tested and

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Owner’s Manual

Installation and Operation

810-02901

(MBK)

810-03201

(PMH)

CASTINS-CSB

CASTINS-CWL

Models:

WARNING

Please read this entire manual
before installation and use of this
pellet fuel-burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.

Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.

• Do not overfi re - If any external part starts to

glow, you are overfi ring. Reduce feed rate.
Overfi ring will void your warranty.

• Comply with all minimum clearances to com-

bustibles as specifi ed. Failure to comply may
cause house fi re.

Check building codes prior to installation.
• Installation MUST comply with local, regional, state

and national codes and regulations.

• Consult local building, fi re offi cials or authorities having

jurisdiction about restrictions, installation inspection,
and permits.

CAUTION

Tested and approved for wood pellets and shelled
fi eld corn fuel only. Burning of any other type of fuel
voids your warranty.

CAUTION

• Important operating and

m a i n t e n a n c e i n s t r u c -
tions included.

Leave this manual
with party respon-
s i b l e f o r u s e a n d
operation.

Read, understand and
follow these instruc-
tions for safe installa-
tion and operation.

DO NOT DISCARD THIS MANUAL

CAUTION

DO NO

T

DISCARD

WARNING

Hot glass will cause burns.

• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as

fi replace.

• A l e r t c h i l d r e n a n d a d u l t s t o h a z a r d s o f h i g h

temperatures.

High temperatures may ignite clothing or other
fl ammable materials.

• Keep clothing, furniture, draperies and other fl ammable

materials away.

HOT SURFACES!

Glass and other surfaces are
hot during operation AND
cool down.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Page 2; SAMPLE OF CLEARANCE TO COMBUSTIBLES LABEL; Castile Pellet Insert; CAUTION; Mfg Date; SAMPLE OF SERIAL NUMBER & DATE OF MANUFACTURE LABEL

Page 2 250-7251G August 20, 2009 R Castile Pellet Insert Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the mark...

Page 3 - Page 3; B. Clearances to Combustibles; Horizontal; TABLE OF CONTENTS

R August 20, 2009 250-7251G Page 3 Castile Pellet Insert Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indi...

Page 4 - Listing and Code Approvals; A. Appliance Certifi cation

Page 4 250-7251G August 20, 2009 R Castile Pellet Insert 1 Listing and Code Approvals A. Appliance Certifi cation C. Glass Specifi cations E. BTU & Effi ciency Specifi cations This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer...

Other Quadra-Fire Models

All Quadra-Fire Other