Heath Zenith SL-5610/15 - Manual
Heath Zenith SL-5610/15 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION
- Page 3 – TEST AND ADJUSTMENT; Maximum Range; SPECIFICATIONS; SENS; Bottom of Sensor; Least Sensitive
- Page 4 – TROUBLESHOOTING GUIDE; No Service Parts Available for this Product
- Page 5 – or; Requisitos; FUNCIONAMIENTO; Resumen de las modalidades del; PRUEBA
- Page 6 – INSTALACION
- Page 7 – PRUEBA Y AJUSTE; Alcance Máximo; ESPECIFICACIONES; ABAJO DEL DETECTOR; Lo menos sensible
- Page 8 – de devolver el producto a la tienda.; No hay piezas de servicio disponibles para este producto.
- Page 9 – ou; Exigences; FONCTIONNEMENT; Résumé du mode de commutation
- Page 11 – Motion; FICHE TECHNIQUE; Le moins sensible; ESSAIS ET RÉGLAGES
- Page 12 – GUIDE DE DÉPANNAGE; SERvICE TECHNIQUE; retourner l’article au magasin.
© 2007 HeathCo LLC
595-5498-09
Motion Sensor
Entryway Light
Models SL-5610/15
The Heath
®
/Zenith Motion Sensor Entryway Light turns
on up to 60 watts of incandescent light when motion
is detected and then, after a selectable time period,
automatically turns the light off. The built-in photocell
keeps the light off during daylight hours.
Sensor
Entryway Light
Mounting Nut and Stem
2 Wire
Connectors
2 Screws
Mounting Strap and
Grounding Wire
globe
(SL-5615)
or
jar
(SL-5610)
Requirements
• The Entryway Light requires 120-volts AC.
• If you want to use Manual Override, the light must be
wired through a switch.
•
Some codes require installation by a qualified
electrician.
This package includes:
OPERATION
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1
TEST
ON-TIME
TEST
... back on.
AUTO
1 Second
OFF
then...
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 10 Min
x
Manual
Until Dawn*
x
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 595-5498-09 INSTALLATION For best performance, mount the fixture about 7ft (2.1 m) above the ground. ❒ Turn the power to the lighting circuit off at the fuse or circuit breaker box. ❒ Remove the existing light fixture. ❒ Install the mounting strap into the junction box. Ori-entation of the strap m...
3 595-5498-09 TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. Avoid aiming the control at: • Objects that change temperature rapidly, such as heat- ing vents or air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the contro...
4 595-5498-09 SYMPTOM Light will not come on. L i g h t c o m e s o n in daylight. POSSIBLE CAUSE 1. Light switch is turned off. 2. Light bulb is loose or burned out. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turnoff is in effect (re- check after dark). 5. Incorrect circuit wiri...