Heath Zenith SL-5211 - Manual
Heath Zenith SL-5211 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; Mounting Sensor
- Page 3 – Bottom of Sensor
- Page 4 – TROUBLESHOOTING GUIDE; before returning product to store.; No Service Parts Available for this Product
- Page 5 – FUNCIONAMIENTO; Resumen de las modalidades del interruptor
- Page 6 – INSTALACION; Montaje del detector
- Page 7 – PRUEBA Y AJUSTE; Parte de abajo del detector; ESPECIFICACIONES
- Page 8 – GUIA DE INVESTIGACION DE AVERIAS; SERVICIO TÉCNICO; de devolver el producto a la tienda.
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Auto
1, 5 or 10 min
x
Manual
Until Dawn*
x
© 2007 HeathCo LLC
595-4238-07
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Override, the control must be
wired through a switch.
• Some codes require installation by a qualified elec-
trician.
OPERATION
Instant Motion Sensor
Light Control
Model SL-5211
Parts
The SL-5211 package includes:
• The Sensor and Lamp Module
• Two mounting screws
Lamp
Module
Existing Light
Fixture
Sensor
Module
Sensor
Cord
Typical Installation
The lamp module is not weather tight. It should only be
used inside of a light fixture.
10 5 1 TEST
ON-TIME
TEST
* resets to Auto Mode at dawn.
ON-TIME
AUTO
10 5 1 TEST
MANUAL MODE
... back on.
1 Second OFF
then...
Mode Switching Summary
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the power
off for one minute, then back on. After the calibration time
the control will be in the AUTO mode.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
Note: When first turned on wait about 1
1
/
2
minutes for the
circuitry to calibrate.
Put the ON-TIME switch on the bottom of
the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or 10
minute position.
Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 10 position.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 595-4238-07 INSTALLATION . ❒ Before proceeding with the installation, TURN OFFTHE POWER TO THE LIGHTING CIRCUIT AT THECIRCUIT BREAKER OR FUSE BOX to avoid electricalshock. There are two types of decorative fixtures that the Instant LightControl should be used with as shown here.‘A’ shows a fixture...
3 595-4238-07 TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. SPECIFICATIONS Range . . . . . . . . . . . . Up to 60 feet (varies with surrounding temperature). Sensing Angle . . . . . . Up to 110 ° Electrical Load . . . . . . 25 to 75 watt IncandescentPower Requirements (Lamps of...
4 595-4238-07 POSSIBLE CAUSE 1. A sensor is positioned too close to the lamp or pointed at nearby objects that cause heat totrigger the sensor. (Reposition the lamp away from the sensor or nearby objects.) 2. Light Control is pointed toward a heat source like an air vent, dryer vent, or brightly-pai...