Heath Zenith SL-5525 - Manual
Heath Zenith SL-5525 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; Eave Mount
- Page 3 – TEST AND ADJUSTMENT; Bottom of Sensor; SPECIFICATIONS
- Page 4 – TROUBLESHOOTING GUIDE; TECHNICAL SERVICE; No Service Parts Available for this Product
- Page 5 – Requisitos; Características; FUNCIONAMIENTO; Mueva el interruptor de; PRUEBA
- Page 6 – INSTALACION; Montaje en alero
- Page 7 – PRUEBA Y AJUSTE
- Page 8 – GUIA DE INVESTIGACION DE AVERIAS; SERVICIO TÉCNICO; No hay piezas de servicio disponibles para este producto
- Page 9 – Exigences; FONCTIONNEMENT; Résumé du mode de commutation
- Page 10 – Montage sous; D’É
- Page 12 – GUIDE DE DÉPANNAGE; SERVICE TECHNIQUE; Aucune pièce de rechange n’est disponible pour ce produit
© 2004 DESA Specialty Products™
595-5295-11
1 Halogen
Lamp
Sensor
Light Control
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Motion Sensing
Halogen Fixture
Model SL-5525
3 Wire
Connectors
6 Screws
(3 sizes included)
Gasket
Mounting Bolt
Mounting Strap
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switch Summary
Flip light switch off
for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Light Shield
Plastic Hanger
Rubber Plug
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Auto
1, 5, 10 min.
x
Manual
Until Dawn*
x
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
This package includes:
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 595-5295-11 INSTALLATION For easy installation, select an existing light with a wallswitch for replacement. For best performance, mount the fixture about 8 ft.(2.4 m) above the ground. W IRE THE L IGHT C ONTROL . ❒ Turn the power to the lighting circuit off at thefuse or circuit breaker box. ❒ Rem...
3 595-5295-11 TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heatsources could cause false triggering. • Areas where pets or traffic may trigger the control....
4 595-5295-11 POSSIBLE CAUSE 1. The lamp is positioned too close to the sensor or pointed at nearby ob-jects that cause heat to trigger thesensor. (Reposition the lamp away from the sensor or nearby objects.) 2. Sensor is pointed toward a heat source like an air vent, dryer vent, orbrightly-painted ...