  • Page 2 – INSTALLATION
  • Page 3 – TEST AND ADJUSTMENT; RANGE; Bottom of Sensor; SPECIFICATIONS
  • Page 4 – TROUBLESHOOTING GUIDE; TECHNICAL SERvICE; No Service Parts Available for this Product
  • Page 5 – • LED indica que se ha detectado movimiento; FUNCIONAMIENTO; Nota: Cuando lo prenda por primera vez es-; pere 1; Mueva el interruptor de; Resumen de las modalidades del; Apague el interruptor; PRUEBA; Prueba; Hasta el
  • Page 7 – Parte de abajo del detector; ESPECIFICACIONES
  • Page 8 – GUIA DE INvESTIGACION DE AvERIAS; SERvICIO TÉCNICO
  • Page 9 – FONCTIONNEMENT; Placer l’interrupteur ON-; Résumé du mode de commutation; Mettre l’interrupteur
  • Page 11 – Bas du détecteur; Portée maximale; FICHE TECHNIQUE
  • Page 12 – GUIDE DE DÉPANNAGE; SERvICE TECHNIQUE
Loading the manual

Replacement
Motion Sensor

Requirements

• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must

be wired through a switch.

Some codes require installation by a qualified
electrician.

© 2007 HeathCo LLC

595-5544-06

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight

hours.

• LED indicates motion was sensed (day or

night).

Model SL-5407

OPERATION

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1

1

/

2

minutes

for the circuitry to calibrate.

ON-TIME

10 5 1 TEST

10 5 1

TEST

ON-TIME

... back on.

1 Second OFF

then...

Put the ON-TIME switch in the 1,
5, or 10 minute position.

Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.

Manual mode only works at night
because daylight returns the sen-
sor to AUTO.

Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Move ON-TIME Switch to

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch

off for one second

then back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn

the power off for one minute, then back on. After
the calibration time the control will be in the AUTO
mode.

TEST

AUTO

MANUAL MODE

Mode:

On-Time

Works: Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Minutes

x

Manual

To Dawn*

x

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION

-2- 595-5544-06 ❒ Swing the sensor head towards the clamp screw. For eave mount only: Controls INSTALLATION ❒ Remove the existing light fixture, if present. These instructions show the sensor wired to flood-lamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the sw...

Page 3 - TEST AND ADJUSTMENT; RANGE; Bottom of Sensor; SPECIFICATIONS

-3- 595-5544-06 Motion Least Sensitive Most Sensitive Sensor Motion The sensor is less sensitive to motion directly to-wards it, most sensitive to motion across its field of view. Maximum Range Maximum Coverage Angle 8 ft. (2.4m) 70 ft. (21m) TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and lig...

Page 4 - TROUBLESHOOTING GUIDE; TECHNICAL SERvICE; No Service Parts Available for this Product

-4- 595-5544-06 TROUBLESHOOTING GUIDE SYMPTOM L i g h t s w i l l n o t come on. Lights come on in daylight. Lights come on for no apparent reason. POSSIBLE CAUSE 1. Light switch is turned off.2. Light is loose or burned out.3. Fuse is blown or circuit breaker is turned off. 4. Daylight turn-off is ...

Other Heath Zenith Models