Table of Contents:

  • Page 2 – EATURES; DO NOT PLUG INTO WALL OUTLET!
  • Page 3 – proper unit operation.; EPLACING THE; Turn the speed control switch on unit to ‘OFF’ position and unplug
  • Page 4 – EPLACING AIR FILTERS; black carbon facing up.; REPLACEMENT PARTS KIT; questions, please contact Field Controls at:; Limited
Loading the manual

UV-AIRE™ AIR PURIFYING SYSTEM

Model: UV-500C

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION

LEAVE

THE

INSTALLATION

INSTRUCTIONS

WITH

THE

OWNER/OPERATOR

OF

THE

DEVICE

AFTER

OPENING

THE

CARTON,

UNPACK

AND

INSPECT

THE

UNIT

AND

LAMP

FOR

DAMAGE.

DO

NOT

INSTALL

THIS

UNIT

IF

ANY

DAMAGE

IS

NOTICEABLE.

SAFETY CONSIDERATIONS

WARNING:

Never expose eyes or skin to UVC light from any source.

Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire™ Air Purifying System with the UV lamp access door open

.

WARNING: DO NOT mount this unit outdoors.

This product is designed for indoor installation only.

WARNING: To avoid electrical shock hazard, do not operate in wet environment.

ITEMS

INCLUDED

IN

SYSTEM:

1-UV-Aire

UV-500C unit

1-Ultra Violet Lamp Individually Boxed
1-Instruction Sheet
4-10” x 10” x 1” Filters
1-Bagged Parts:

containing lamp

connector, alcohol swab and
access door screw

The high intensity ultraviolet light attacks airborne mold, bacteria, and viruses. The high efficiency filter traps

allergens, dust, and pollen. The carbon filter removes odors and attacks VOC’s (volatile organic compounds).

*For best results, operate
the UV-500 continuously
24 hours a day

.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - EATURES; DO NOT PLUG INTO WALL OUTLET!

Page 2 I. INDICATION FOR USE This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition. II. GENERAL INFORMATION Model Volts Amps Hz Watts Lamp Intensity at 1 met...

Page 3 - proper unit operation.; EPLACING THE; Turn the speed control switch on unit to ‘OFF’ position and unplug

Page 3 10. Slide the filter drawer out of the base. Remove one the four filters from its plastic bag and place it in the drawer with arrow/carbon side up. (See Figure 6) 11. Slide the filter drawer with filter back into the base unit. Press firmly until drawer catches. NOTE: The positive catch elimi...

Page 4 - EPLACING AIR FILTERS; black carbon facing up.; REPLACEMENT PARTS KIT; questions, please contact Field Controls at:; Limited

Page 4 3. Disconnect the lamp connection, then rotate lamp-mounting knob counter-clockwise and pull the lamp out of the unit. (See Figure 10 & 11) 4. Remove lamp carefully, by un-plugging the lamp from the lamp-mounting knob. (See Figure 12) NOTE: When replacing the lamp, always wipe off lamp wi...