Field Controls WML-C - Manual

Field Controls WML-C

Field Controls WML-C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – TABLE OF CONTENTS
  • Page 3 – NOTE; DOWN-FLOW INSTALLATION
  • Page 4 – SUSPENDED INSTALLATION; Fig 1 Suspended Installation
  • Page 5 – Standard; IMPORTANT; : The chimney must be; DRAFT REGULATOR CONTROL
  • Page 7 – OPTIONAL SIDE WALL VENTING; Direct Venting; Table 3: Minimum Chimney Base; OIL TANK; Installation; PIPING INSTALLATION; ELECTRICAL CONNECTIONS
  • Page 8 – CIRCULATING AIR BLOWER
  • Page 9 – THE NEUTRAL WIRE; off both ends of the unused; HUMIDIFIER; OIL BURNER NOZZLES
  • Page 10 – BURNER ELECTRODES; fuel to air; Note A; : Locate hole at least 6 inches on; Note B; 2 inches from breeching or elbow.; SMOKE TEST NOTE
  • Page 11 – : Be sure that the home; MAINTENANCE AND SERVICE; B: Annual Service By Contractor; and
  • Page 12 – OPERATING INSTRUCTIONS; the difference in
  • Page 13 – (For use with sidewall vented units using outdoor combustion air)
  • Page 14 – Beckett AF Burner
  • Page 17 – APPENDIX B: WIRING DIAGRAMS; Beckett AF Burner Wiring Diagram
  • Page 18 – Beckett AFII Burner Wiring Diagram
  • Page 19 – Riello 40F3 and F5 Burner Wiring Diagram
  • Page 20 – Riello 40BF3 Burner Wiring Diagram
  • Page 21 – OPERATION OF OIL BURNER; Restore electrical power to the furnace.
  • Page 22 – Thermostat calls for heat
  • Page 26 – R7184 LED DIAGNOSTIC LIGHT; NORMAL CONDITIONS; TROUBLESHOOTING; Electrical Shock Hazard
  • Page 29 – TABLE C4: SYSTEM AND GENERAL TROUBLESHOOTING; Problem Possible
  • Page 30 – TABLE C-4: SYSTEM AND GENERAL TROUBLESHOOTING
  • Page 31 – FINAL CHECK OUT
Loading the manual

Installation, Operation and

Maintenance Manual

Oil Fired Warm Air Furnaces

WML-C AND MPL-B

(Down-Flow or Horizontal Model)

ALL INSTALLATIONS MUST MEET ALL

LOCAL, PROVINCIAL/STATE, AND

FEDERAL CODES WHICH MAY

DIFFER FROM THIS MANUAL

ECR International Limited

OLSEN Division

Read this complete manual before
beginning installation. These
instructions must be kept with the
furnace for future reference.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS

30318 R4 9/9/2005 2 TABLE OF CONTENTS INTRODUCTION.......................................................................................................................................................................... 3 HEAT LOSS.......................................................................

Page 3 - NOTE; DOWN-FLOW INSTALLATION

30318 R4 9/9/2005 3 IMPROPER INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITI...

Page 4 - SUSPENDED INSTALLATION; Fig 1 Suspended Installation

30318 R4 9/9/2005 4 HORIZONTAL INSTALLATION WML-C AND MPL-B furnaces models are assembled and shipped ready for installation in the down-flow position. The furnace may be installed in either of the horizontal positions; warm air discharging left or warm air-discharging right by following these steps...