Page 2 - SIMPLIFIED INSTALLATION INSTRUCTIONS; DETAILED INSTALLATION INSTRUCTIONS; INSULATE WATER TANK RESERVOIR; DO NOT INSTALL this unit in an attic period. Do Not; It is highly recommended but not required that the; MOUNTING TEMPLATE
SIMPLIFIED INSTALLATION INSTRUCTIONS DETAILED INSTALLATION INSTRUCTIONS 1. Insulate the water reservoir. See figure 3. 2. Select the mounting location on the duct and tape on the mounting template. 3. Drill the (8) 1/8" mountings holes. 4. Cut out the humidifier opening in the duct. 5. Insert th...
Page 3 - tightening the hex compression nut, tighten only enough to; CORRECT; CONDENSATE
6. WATER SUPPLY - Required Criteria 9. WIRING THE STEAM HUMIDIFIER 7. M OUNTING THE STEAM HUMIDIFIER 8. STEAM OPERATION - Required Criteria A. WATER SUPPLY USING THE SADDLE VALVE FURNISHED WITH UNIT. Important! See page 14. A. INSTALLING AND WIRING THE HUMIDISTAT B. OVERFLOW & DRAIN LINES - Requ...
Page 4 - blower on the HVAC system does not operate when called; across the normally open contacts with the fan/blower running.; Heat Pump System and Steam Humidifier; We recommend our new Model APD switch.
Typi ca l Furnace S2000 & S2020 Humidifier Low Voltage Terminal Block G1 R G2 H H Heat only Thermostat W R G W R Heat Only System and Steam Humidifier with standard dry contact Humidistat Dry Contact Humidistat A A FIG. 6 Factory Jumper will stay in place unless a field installed Air Proving Dev...
Page 5 - Field Controls Steam Humidifiers
8.00” 6.00” 7. 50 ” 8.25” 10. 50” 11. 60” the room needed to install the unit in a certain location. The data can also be used to determine the minimum duct size the Steam Humidifier can be inserted into. The Steam Humidifier should not obstruct more than 25% of the cross sectional area of the selec...
Page 6 - Copyright; Suitable locations
For R epla cem ent P arts Ca ll (8 00) 4 46-3 110 090 21A 0118 U.S. PAT ENT NU MBE R 57 58 0 18 seria l nu mber Ewc 385 Hig hwa y 33 , E nglis htow n, N J 07 726 CON TRO LS, IN C. UL ® C US LIST ED 1 41V POW ER DRA IN FILL HEA TER BLO WER The rmis tor Heat er Wate r Suita ble f or R esid entia l U s...
Page 7 - RELATIVE HUMIDITY CHART; Installation instructions for the 072000 model; SETTING THE HUMIDISTAT; RH; Outside; Recommended Indoor; and up; Variable Speed WIRING DIAGRAM; Variable Speed Heat & Cool System and; capacities while operating.
It is recommended that humidistat settings of 30-45% not be exceeded. If condensation is noticed on windows during very cold outside temperatures, the humidistat setting should be lowered. RELATIVE HUMIDITY CHART The maximum recommended relative humidity for your home depends upon many factors such ...
Page 8 - INITIAL START-UP * SEQUENCE OF OPERATION * SERVICE “LED” INDICATORS; blink rapidly during Maintenance mode.; SERVICE “LED” INDICATORS
INITIAL START-UP * SEQUENCE OF OPERATION * SERVICE “LED” INDICATORS 11. START -UP & OPERATING SEQUENCE Once the Steam Humidifier has been installed and the water, drain, humidistat and blower interlock connections completed, the humidifier may be started. A. Disconnect the water line. Turn on th...
Page 9 - SERVICE INDICATORS; If necessary, fill the tank; LED LIGHT EXPLANATION; IMPORTANT NOTE; Steam Humidifier
14. SERVICE INDICATORS Seven LED lamps provided on the front panel indicate the functional status of the humidifier as shown in Figure 7 below. 9 A. L. M. N. O. B. C. D. E. F. G. H. I. J. K. Unplug the power cord from the 120 volt source for S2000 (240 volt for S2020) and allow the water to cool for...
Page 10 - DO NOT cut off the grounded plug and/or; This will void the warranty.
10 A. G. B. C. D. E. F. The green "Power" light does not blink off and on. 1. The S2000 is not connected to an active 120 VAC 15 Amp power source. (S2020, 240 VAC, 10 AMP). 2. Call the Technical Support Hotline. The "HEATER" LED does not illuminate. 1. The humidistat is not closed, c...
Page 11 - SERVICE AND REPLACEMENT PARTS
SERVICE AND REPLACEMENT PARTS 11 ITEM 1 120 VOLT HEATER ASSEMBLY240 VOLT HEATER ASSEMBLY24 VOLT SOLENOID VALVE ASSEMBLY WATER LEVEL PROBE ASSEMBLY THERMISTOR PROBE ASSEMBLY CIRCUIT BOARD ASSEMBLYDRAIN VALVE ASSEMBLYTANK BAFFLE WATER HAMMER ARRESTER (not shown)ANODE INSULATION KIT (not shown) 2002200...
Page 13 - Smart Digital Humidistat; Installation and Owner's Manual; down; The outdoor sensor is not required to; General Description; TECHNICAL BULLETIN; space. Field Controls recommends an
Smart Digital Humidistat Installation and Owner's Manual The 072000 is a digital humidifier control that can automatically adjust the indoor humidity set point as the outside air temperature changes. This intelligent control will maintain accurate humidity levels and a more comfortable indoor enviro...
Page 14 - APPLICATION NOTE; SUPPLEMENT TO THE; s job is to become the target of mineral attack, so it will be heavily
Z100 ASSEMBLY INSTALLATION INSTRUCTIONS & OWNER'S MANUAL Z100 REPLACEMENT INSTRUCTIONS ELECTRONIC STEAM POWER HUMIDIFIERS MODEL # S2000 AND S2020 APPLICATION NOTE AN 131 Copyright © 2011 Field Controls All Rights Reserved. SUPPLEMENT TO THE The Field Controls Steam Humidifier now comes equipped ...
Page 15 - DECORATIVE COVER
APPLICATION NOTE PART # 2009 AN 151 SC100 - PART # 2009 DECORATIVE COVER S2000/S2020 STEAM HUMIDIFIER SC100 Installation Instructions P/N 090376A0151 REV. A Copyright 2011 © Field Controls Inc., All Rights Reserved SUPPLEMENT TO THE ELECTRONIC STEAMPOWER HUMIDIFIERSMODEL # S2000 AND S2020 The Field ...